Antimicrobial Efficacy of the Silver Wound Dressing Biatain Ag in a Disc Carrier Test Simulating Wound Secretion

  • Aim: The efficacy of antimicrobial compounds included in wound dressings has been determined using the quantitative suspension test according to EN 13727 before. However, as suspension tests are not an accurate reflection of the conditions under which wound antiseptics are used, it was investigated if a disc carrier test would yield results simulating practical conditions on wound surfaces. A silver-leaching foam wound dressing was used for evaluation of the disc carrier test method. Method: The disc carriers consisted of circular stainless-steel discs measuring 2 cm in diameter and 1.5 mm in thickness, complying with the requirements of EN 10088-2. Carriers were contaminated with Staphylococcus aureus, methicillin-resistant S. aureus or Pseudomonas aeruginosa, respectively, together with an artificial wound secretion and left to dry at room temperature for 30 min. The wound dressings being tested were placed on the discs for the length of the exposure time, and after neutralization by thioglycolate in phosphate-buffered saline the number of surviving test organisms was then counted. The logarithmic reduction factor was calculated from the difference between the initial inoculum and the number of recovered test organisms. Results: The disc carrier test allowed determination of an antimicrobial efficacy in a realistic setting. It also imposed more stringent requirements on efficacy over time than the quantitative suspension test. The silver foam wound dressing showed a time-dependent antimicrobial efficacy. After 24-hour application time, the reduction factors against S. aureus, P. aeruginosa and the methicillin-resistant S. aureus were 1.9 ± 0.15, 2.1 ± 0.14 and 3.1 ± 0.18, respectively. Conclusion: The disc carrier test was a useful method for testing the antimicrobial efficacy of a foam silver dressing. The antimicrobial dressing exhibited an antimicrobial effect after 3 h and achieved a reduction >2 log against the tested bacterial strains in the presence of a simulated wound secretion after 24 h.

Download full text files

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author: M. Ebert, O. Assadian, N.-O. Hübner, T. Koburger, A. Kramer
URN:urn:nbn:de:gbv:9-opus-30813
DOI:https://doi.org/10.1159/000330761
ISSN:1660-5527
ISSN:1660-5535
Pubmed Id:https://pubmed.ncbi.nlm.nih.gov/21832866
Parent Title (English):Skin Pharmacology and Physiology
Publisher:S. Karger AG
Place of publication:Basel, Switzerland
Document Type:Article
Language:English
Date of first Publication:2011/08/11
Release Date:2020/09/29
Tag:Antimicrobial efficacy; Biatain Ag; Silver wound dressing; Wound secretion
GND Keyword:-
Volume:24
Issue:6
First Page:337
Last Page:341
Faculties:Universitätsmedizin / Institut für Hygiene und Umweltmedizin
Licence (German):License LogoUrheberrechtlich geschützt