Distribution of Mean, Systolic and Diastolic Ocular Perfusion Pressure in Telemedical Homemonitoring of Glaucoma Patients

  • Background: To analyze the relation and distribution of mean, systolic and diastolic ocular perfusion pressure (OPP) in telemedical homemonitoring of patients with primary open-angle glaucoma (POAG). Methods: 70 patients with POAG measured intraocular pressure (IOP) and blood pressure at home for a period of 6 months with the Goldmann applanation self-tonometer Ocuton S and the blood pressure device boso medicus PC. Twenty-four-hour profiles were taken every 4 weeks in addition to single measurements in the morning and evening once a week. All measured values were transmitted to an electronic patient record, which calculated OPP by taking systolic, diastolic and mean arterial blood pressure and subtracting IOP. Results: We analyzed 3,282 values of mean, systolic and diastolic OPP. The quantity of values below the risk levels of the Barbados Eye Studies was calculated. We found values lower than the risk levels for LE: 49 (1.5%)/RE: 60 (1.8%) systolic OPP, LE: 1,623 (49.5%)/RE: 1,761 (53.7%) diastolic OPP and LE: 687 (20.9%)/RE: 794 (24.2%) mean OPP. The individual average OPP levels of all 70 patients below the risk levels showed the following distribution: LE: 4 (5.7%)/RE: 6 (8.6%) systolic OPP, LE: 19 (27.1%)/RE: 20 (28.6%) diastolic OPP and LE: 10 (14.3%)/RE: 10 (14.3%) mean OPP. Conclusion: The individual distribution of different OPP values in POAG patients is not easy to interpret for clinical ophthalmologists. Precise practicable guidelines for clinical use still have to be determined.

Download full text files

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author: Clemens Jürgens, Rico Grossjohann, Frank Tost
URN:urn:nbn:de:gbv:9-opus-31018
URL:http://www.karger.com/ore
DOI:https://doi.org/10.1159/000338234
ISSN:0030-3747
ISSN:1423-0259
Pubmed Id:https://pubmed.ncbi.nlm.nih.gov/22890219
Parent Title (English):Ophthalmic Research
Publisher:S. Karger AG
Place of publication:Basel, Switzerland
Document Type:Article
Language:English
Date of first Publication:2012/08/09
Release Date:2020/09/29
Tag:Glaucoma; Ocular perfusion pressure; Ocular tonometry; Telemedicine
GND Keyword:-
Volume:48
Issue:4
First Page:208
Last Page:211
Faculties:Universitätsmedizin / Klinik und Poliklinik für Augenheilkunde
Licence (German):License LogoUrheberrechtlich geschützt