Refine
Year of publication
Document Type
- Article (10)
- Conference Proceeding (1)
Language
- English (11)
Has Fulltext
- yes (11)
Is part of the Bibliography
- no (11)
Keywords
- - (7)
- magnetron sputtering (3)
- HiPIMS (1)
- Langmuir probe diagnostics (1)
- N incorporation (1)
- Ti-Cu-N coating (1)
- Transmission electron microscopy (1)
- X-ray diffraction (1)
- X-ray photoelectron spectroscopy (1)
- bipolar pulse (1)
Institute
- Institut für Physik (10)
Publisher
- IOP Publishing (7)
- MDPI (2)
- AIP Publishing (1)
- Springer Nature (1)
Tunable diode laser absorption spectroscopy of argon metastable atoms in Ar/C2H2 dusty plasmas
(2009)
The tunable diode laser absorption spectroscopy method was used to measure Ar metastable density in order to study the dust growth process in hydrocarbon-containing plasmas. A simple model was proposed that successfully interprets the experimental results of pristine plasmas. The model is also suitable for explaining the influence of dust particle size on metastable density and for examining the dust growth process. The metastable density responded strictly to the formation of dust particles and their growth in processing plasmas. Using metastable density as an indicator is, therefore, a non-intrusive and effective method for the study of the dust growth process in hydrocarbon-containing plasmas.
Abstract
Reactive high power impulse magnetron sputtering (HiPIMS) of a cobalt cathode in pure argon gas and with different oxygen admixtures was investigated by time-resolved optical emission spectroscopy (OES) and time-integrated energy-resolved mass spectrometry. The HiPIMS discharge was operated with a bipolar pulsed power supply capable of providing a large negative voltage with a typical pulse width of 100 μs followed by a long positive pulse with a pulse width of about 350 μs. The HiPIMS plasma in pure argon is dominated by Co+ ions. With the addition of oxygen, O+ ions become the second most prominent positive ion species. OES reveals the presence of Ar I, Co I, O I, and Ar II emission lines. The transition from an Ar+ to a Co+ ion sputtering discharge is inferred from time-resolved OES. The enhanced intensity of excited Ar+* ions is explained by simultaneous excitation and ionisation induced by energetic secondary electrons from the cathode. The intensity of violet Ar I lines is drastically reduced during HiPIMS. Intensity of near-infrared Ar I lines resumes during the positive pulse indicating an additional heating mechanism.
AbstractThe performance of a positively biased external ring anode in combination with a hollow cathode (HC) discharge or a magnetron sputtering (MS) discharge, both with a Ti cathode and with Ar as working gas, is investigated. Plasma and floating potential increase as function of anode voltage. Energy-resolved mass spectrometry reveals that the kinetic energy of argon and titanium ions is enhanced by a positive anode voltage allowing for an effective energy control of plasma ions.
Surface Stoichiometry and Depth Profile of Tix-CuyNz Thin Films Deposited by Magnetron Sputtering
(2021)
Behavior of a porous particle in a radiofrequency plasma under pulsed argon ion beam bombardment
(2010)
The behavior of a single porous particle with a diameter of 250 μm levitating in a radiofrequency (RF) plasma under pulsed argon ion beam bombardment was investigated. The motion of the particle under the action of the ion beam was observed to be an oscillatory motion. The Fourier-analyzed motion is dominated by the excitation frequency of the pulsed ion beam and odd higher harmonics, which peak near the resonance frequency. The appearance of even harmonics is explained by a variation of the particles's charge depending on its position in the plasma sheath. The Fourier analysis also allows a discussion of neutral and ion forces. The particle's charge was derived and compared with theoretical estimates based on the orbital motion-limited (OML) model using also a numerical simulation of the RF discharge. The derived particle's charge is about 7–15 times larger than predicted by the theoretical models. This difference is attributed to the porous structure of the particle.
Copper tungsten oxide films are deposited with the help of reactive high power impulse magnetron sputtering (HiPIMS) in an argon/oxygen gas mixture. Two magnetrons, one equipped with a tungsten target and the other with a copper target, are employed. The HiPIMS discharge is operated with a repetition frequency of f=100 Hz. Pulse widths of 100 and 20 µs separated by 25 µs are chosen for the tungsten and copper target, respectively. Films deposited on two different glass substrates [soda lime glass and fluorine doped tin oxide (FTO) coated glass] are characterized by energy dispersive x-ray spectroscopy, x-ray photoelectron spectroscopy, x-ray diffraction, Raman spectroscopy, and ellipsometry. Photoelectrochemical activity was investigated by linear voltammetry. The composition and crystal structure of as-deposited and annealed films are found to depend on the deposition conditions. Annealed films deposited on FTO glass are composed of WO3 and CuWO4 or Cu2WO4 crystal phases. Films deposited on soda lime glass are subject to sodium diffusion into the films during annealing and the formation of Na2W2O7 and Na2W4O13 phases.
A hollow cathode discharge with a Ti cathode and a positively biased ring anode was operated in Ar + N2 or Ar + O2 gas mixtures. The energy distribution of plasma ions is investigated with the help of energy-resolved mass spectrometry. Singly and doubly charged Ar+ and Ar2+ ions and molecular N+2 or O+2 ions are the most abundant ionic species. The kinetic energy of all plasma ions is enhanced by a positive anode voltage.
The pulse length dependence of a reactive high power impulse magnetron sputtering (HiPIMS) discharge with a tungsten cathode in an argon+oxygen gas mixture gas was investigated. The HiPIMS discharge is operated with a variable pulse length of 20–500 µs. Discharge current measurements, optical emission spectroscopy of neutral Ar, O, and W lines, and energy-resolved ion mass spectrometry are employed. A pronounced dependence of the discharge current on pulse length is noted while the initial discharge voltage is maintained constant. Energy-resolved mass spectrometry shows that the oxygen-to-tungsten (O+/W+) and the tungsten oxide-to-tungsten (WO+/W+) ion ratio decreases with pulse length due to target cleaning. Simulation results employing the SDTrimSP program show the formation of a non-stoichiometric sub-surface compound layer of oxygen which depends on the impinging ion composition and thus on the pulse length.
Interaction of injected dust particles with metastable neon atoms in a radio frequency plasma
(2008)
Spatial density and temperature profiles of neon metastables produced in a radio frequency (rf) discharge were investigated by means of tunable diode laser absorption spectroscopy. The experiments were performed in the PULVA1 reactor, which is designed for the study of complex (dusty) plasmas. The line averaged measured density is about 1.5×1015 m−3 in the bulk and drops almost linearly in the plasma sheath. The gas temperature is in the range of 370–390 K. The flow of metastable atoms in the plasma sheath deduced from the spatial density distribution is dominated by the flow towards the rf electrode. The sheath length is supposed as the effective diffusion length in the plasma sheath region. This approximation was used to investigate the interaction of injected particles with the plasma. The observations and estimation provide evidence for a significant interaction between metastable atoms and powder particles which is important for energy transfer from the plasma to the particles. The power per unit area absorbed by dust particles due to the collision of metastable atoms with the dust particle surface is in the range of a few tens of mW m−2.
A research of the temperature effect of the muon cosmic ray (CR) component on the MuSTAnG super telescope data (Greifswald, Germany) for the whole period of its work (from 2007) was carried out. The primary hourly telescope's data were corrected for the temperature effect, using vertical temperature atmospheric profile at the standard isobaric levels obtained from the GFS model. To estimate the model accuracy and applicability the air sounding data for some years were used.