Refine
Document Type
- Article (2)
- Doctoral Thesis (1)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- - (1)
- Apocynin (1)
- NADPH-Oxidase (1)
- Reaktive Sauerstoffspezies (1)
- Spontan hypertensive Ratten (1)
- cost analysis (1)
- donor human milk (1)
- maternal breast milk (1)
- milk bank (1)
- preterm infant (1)
Institute
Publisher
Zahlreiche Studien liefern Erkenntnisse über den Zusammenhang zwischen reaktiven Sauerstoffspezies und der Entstehung kardiovaskulärer Erkrankungen, wie der Hypertonie. Besonders NADPH-Oxidase-abhängige Sauerstoffradikale wurden als wichtige krankheitserzeugende Faktoren in der Entwicklung und Aufrechterhaltung kardiovaskulärer Erkrankungen, wie der arteriellen Hypertonie identifiziert und Substanzen erforscht, die zu experimentellen und therapeutischen Zwecken die NADPH-Oxidase-Aktivität hemmen. Das Ziel dieser Arbeit bestand darin, durch frühzeitige Behandlung spontan hypertensiver Ratten mit einer Substanz, die NADPH-Oxidase-hemmende Eigenschaften hat, eine langfristige Blutdrucksenkung und eine Verbesserung der endothelvermittelten Vasodilatation zu erreichen. Dazu wurde eine Gruppe von 8 SHR über das Trinkwasser mit dem NADPH-Oxidase-Hemmer Apocynin behandelt und mit Hilfe der Radiotelemetrie der systolische, diastolische Blutdruck sowie die Herzfrequenz registriert. Die Apocynin-behandelten SHR wurden mit einer Gruppe von 6 unbehandelten SHR-Kontrolltieren verglichen. Neben diesen Experimenten wurden Untersuchungen zur Endothelfunktion Apocynin-behandelter SHR an isolierten renalen Interlobar- und Koronararterien und zur vasodilatierenden Wirkung von Apocynin an Interlobar- und Koronararterien von F344 Ratten mit einem Small-Vessel-Myographen durchgeführt. Die Ergebnisse dieser Arbeit konnten zeigen, dass die Behandlung der SHR mit Apocynin bis zur 8. Lebenswoche keine langfristige Blutdrucksenkung zur Folge hatte. Der Vergleich beider Gruppen hinsichtlich der Blutdrücke ergab keinen statistisch signifikanten Unterschied. Die Untersuchungen zur endothelvermittelten Vasodilatation mit Acetylcholin an isolierten renalen Interlobar- und Koronararterien Apocynin-behandelter und unbehandelter SHR zeigten, dass durch die Behandlung der SHR mit Apocynin keine Verbesserung der renalen und koronaren Endothelfunktion im Vergleich zu den Kontrollen resultierte. Die Experimente zur Klärung der Mechanismen, die die vasodilatierende Wirkung von Apocynin vermitteln ergaben, dass durch die Hemmung der NADPH-Oxidase-abhängigen Sauerstoffradikale, durch die Abwesenheit von extrazellulärem Kalzium, durch Kalium und durch die Inhibition der Proteinkinase A und G die Apocynin-induzierte Vasodilatation nicht signifikant gehemmt wurde. Durch die Inkubation der Arteriensegmente mit dem Rho-Kinase-Hemmer Y-27632 wurde die Vasopressin-induzierte Vasokonstriktion signifikant abgeschwächt und die kumulative Zugabe von Apocynin zeigte keine zusätzliche Wirkung auf die Wandspannung. Diese Ergebnisse belegen, dass die renalen Interlobar- und Koronararterien von SHR und F344 Ratten auf Apocynin mit einem ausgeprägten Dilatationsverhalten reagierten, die Vasodilatation jedoch nicht über eine Hemmung der NADPH-Oxidase, vermutlich aber über eine Hemmung der Rho-Kinase vermittelt wird.
Abstract
Aim
This study analysed the comparative cost of feeding donor human milk to preterm infants compared to mother's own milk and formula.
Methods
A document and process analysis and a time measurement study were carried out at the milk bank of the Level 1 Perinatal Center of the University Hospital of Greifswald, Germany, from April to June 2017. The cost analysis data were provided by the University's financial department.
Results
The total cost per year was €92 085.02 for 300 litres of donor human milk: 27% of this was material costs, 51% was personnel costs, and 22% was other overheads. The average cost per litre was €306.95, and staff time was 492 minutes per litre. The total marginal cost for each additional litre of donor human milk, formula or unpasteurised mother´s milk was €82.88, €10.28 and €38.42, respectively. Pasteurising a litre of donor milk cost €3.51.
Conclusion
Providing preterm infants with donor milk was much more expensive than using formula or mother's own milk, but the cost of pasteurisation was minimal.
Background
Numerous wearables are used in a research context to record cardiac activity although their validity and usability has not been fully investigated. The objectives of this study is the cross-model comparison of data quality at different realistic use cases (cognitive and physical tasks). The recording quality is expressed by the ability to accurately detect the QRS complex, the amount of noise in the data, and the quality of RR intervals.
Methods
Five ECG devices (eMotion Faros 360°, Hexoskin Hx1, NeXus-10 MKII, Polar RS800 Multi and SOMNOtouch NIBP) were attached and simultaneously tested in 13 participants. Used test conditions included: measurements during rest, treadmill walking/running, and a cognitive 2-back task. Signal quality was assessed by a new local morphological quality parameter morphSQ which is defined as a weighted peak noise-to-signal ratio on percentage scale. The QRS detection performance was evaluated with eplimited on synchronized data by comparison to ground truth annotations. A modification of the Smith-Waterman algorithm has been used to assess the RR interval quality and to classify incorrect beat annotations. Evaluation metrics includes the positive predictive value, false negative rates, and F1 scores for beat detection performance.
Results
All used devices achieved sufficient signal quality in non-movement conditions. Over all experimental phases, insufficient quality expressed by morphSQ values below 10% was only found in 1.22% of the recorded beats using eMotion Faros 360°whereas the rate was 8.67% with Hexoskin Hx1. Nevertheless, QRS detection performed well across all used devices with positive predictive values between 0.985 and 1.000. False negative rates are ranging between 0.003 and 0.017. eMotion Faros 360°achieved the most stable results among the tested devices with only 5 false positive and 19 misplaced beats across all recordings identified by the Smith-Waterman approach.
Conclusion
Data quality was assessed by two new approaches: analyzing the noise-to-signal ratio using morphSQ, and RR interval quality using Smith-Waterman. Both methods deliver comparable results. However the Smith-Waterman approach allows the direct comparison of RR intervals without the need for signal synchronization whereas morphSQ can be computed locally.