Refine
Document Type
- Doctoral Thesis (8)
Language
- English (8)
Has Fulltext
- yes (8)
Is part of the Bibliography
- no (8)
Keywords
- mass separation (3)
- Flugzeitspektrometrie (2)
- MR-ToF MS (2)
- MR-ToF device (2)
- Metallcluster (2)
- Multi-reflection time-of-flight mass spectrometry (2)
- Penningfalle (2)
- Polyanion (2)
- atomic clusters (2)
- laser spectroscopy (2)
Institute
This thesis presents the production of polyanionic clusters within two ion storage devices:
Considering a Penning trap, the accessible range of polyanionic aluminium clusters has been expanded up to the 10th charge state. In particular, abundance curves for clusters with 5 to 9 excess electrons have been measured for the first time and analysed with respect to their lifetime-dependent appearance sizes. These sizes reveal a nearly quadratic dependency on the charge state for experimentally accessible lifetimes.
Additionally, the production of polyanionic clusters has been enabled in a radiofrequency ion trap. Therefore, the transition from a harmonic to a digital 2- and 3-state guiding signal has been investigated with respect to the ion storage. The passing of electrons through the trap during field-free periods of the guiding signal led to the first production of polyanionic clusters within a radiofrequency ion trap.
This thesis describes recent developments in multi-reflection time-of-flight mass spectrometry (MR-ToF MS) with ions exhibiting large masses and mass differences at an MR-ToF setup at the University of Greifswald. A series of in-trap manipulation techniques to selectively retain or eject ion bunches of multiple species with disparate mass-to-charge ratios is investigated. These highlight the possibility to correct long-term flight-time drifts using a reference ion species far away in mass from the species of interest and also the ability to use such a pair to perform single-reference precision mass determinations. In both cases, the results obtained with disparate-mass ion pairs are comparable to those known from operation with isobaric species.
In addition, an in-trap photoexcitation technique is developed and applied to study the dissociation behavior of atomic bismuth clusters (systems of some number of bismuth atoms). Compared to previous works by other groups, the probed cluster-size range is expanded for both ion polarities, resulting in a more comprehensive picture of the underlying dissociation pathways. The known significance of neutral-tetramer breakoff is confirmed, however, evidence is also found for the loss of larger neutral fragments.
Lastly, the principle of tandem high-resolution MR-ToF MS is introduced. This new method allows the study of the change in dissociation behavior of the cationic bismuth octamer resulting from substituting one of its atoms for lead. It is found that the lead-doping opens new preferential fragmentation pathways that outstrip the dominant tetramer breakoff for this specific precursor cluster size. As a first proof-of-principle experiment, the case of the cationic octamer shows that tandem MR-ToF MS is well-suited for the investigation of compound clusters.
This thesis describes experiments with clusters stored in an electrostatic ion trap called Multi-reflection time-of-flight (MR-ToF) analyzer. These devices are established as mass separators and analyzers with high resolving powers and fast processing times. The objective was to characterize an experiment that utilizes such analyzer for cluster research, to this end a laser-ablation ion source was combined with an MR-ToF analyzer.
In the first part, an experiment scheme that combines two operating modes, namely in-trap lift operation and mirror operation, is presented and characterized for the present setup. For ion capture in-trap lift switching was employed and exit-side mirror switching for ejection with higher information content. Measurements were performed with small lead clusters to illustrate individual advantages of both techniques and the gain of combining them with focus on the ions’ ToF ejection window.
In the second part, a recently introduced method of ion separation by transversal ejection of unwanted species inside the trap was studied for the present setup. The ejection is performed by appropriate pulses of the potentials of deflector electrodes located in the trap. The various parameters affecting the selection effectivity and resolving power are illustrated with tin-cluster measurements, with resolving powers of up to several tens of thousands.
The third part presents the experiment in detail, with the construction of each component and measurements for its various performance parameters. Because the heart of the setup is the MR-ToF analyzer the characterization focuses on the trap. In addition, cluster ions were mass selected in the MR-ToF device and photodissociated. The charged fragments were stored and mass analyzed in a proof-of principle MS/MS experiment where both MS steps were performed in the MR-ToF operation mode.
Lead-cluster investigations
(2017)
In this thesis, investigations on lead clusters stored in a Penning trap are presented. The measurements are performed at the ClusterTrap setup at the Institute of Physics of the University of Greifswald. A Penning trap with a superconducting magnet (B=12 Tesla) makes up the central part of the experiment. In this trap, singly positively or negatively charged lead clusters (a group of lead atoms) are stored, their amplitudes of motion are cooled, and a specific cluster size is selected. Thus, clusters of only a single size are prepared for experimental investigation. After interactions with electrons and/or photons, the trap content is extracted and analyzed by time-of-flight mass spectrometry.
In the first experiment, the size-selected clusters are excited by a frequency-doubled Nd:YAG laser, which leads to fragmentation processes. The preferred fragmentation pathway, which is observed to be break-off of a seven-atom neutral cluster is unusual for metal clusters, which typically evaporate monomers. Furthermore, the already known magic cluster sizes are observed.
In a subsequent experiment, positively charged lead clusters with 31 atoms are irradiated with laser light and fragmentation processes are time resolved investigated. The assumption that lead clusters fragment by break-off of neutral heptamers is confirmed.
In the following experiment, an electron beam is guided through the Penning trap to ionize pulsed-in argon atoms. While the positive argon ions leave the trap, the secondary electrons are trapped together with the selected lead clusters. This allows the electrons to attach to the singly charged lead clusters, which leads to multiply negatively charged lead clusters. The relative abundance of multiply-charged clusters is measured with respect to the cluster size, from which the appearance sizes of di- and trianions can be calculated. In addition to the attachment of electrons, fragmentation products similar to those of the photoexcitation measurements are observed. Furthermore, the cluster sizes 10 and 12 are observed regardless of the investigated precursor size, together with clusters of the precursor size reduced by 10 and 12. This is a first hint for a fission process of doubly negatively charged lead clusters into two singly charged products. In a following measurement, doubly charged lead clusters are produced and photoexcited. The observed abundance spectra confirm this assumption.
Development of an Electrostatic Ion Beam Trap for Laser Spectroscopy of Short-lived Radionuclides
(2021)
Due to its high accuracy and resolution, collinear laser spectroscopy (CLS) is a powerful tool to measure nuclear ground state properties such as nuclear spins, electromagnetic moments and mean-square charge radii of short-lived radionuclides. Performing CLS with fast beams (>30 keV) provides an excellent spectral resolution approaching the natural linewidth. However, its fluorescence-light detection limits its successful application to nuclides with yields of more than several 100 to 10,000 ions/s, depending on the specific case and spectroscopic transition. To extend its reach to the most exotic nuclides with very low production yields far away from stability, more sensitive methods are needed. For this reason, the novel Multi Ion Reflection Apparatus for CLS (MIRACLS) is currently under development at ISOLDE/CERN. This setup aims to combine the high resolution of conventional fluorescence based CLS with a high experimental sensitivity, enhanced by a factor of 30 to 700 depending on the mass and lifetime of the studied nuclide. By repetitively reflecting the ion beam between the electrostatic mirrors of an electrostatic ion beam trap, often also called Multi-Reflection Time of Flight (MR-ToF) device, the laser beam probes the ion bunch during each revolution. Therefore, the observation time is extended and the experimental sensitivity is enhanced compared to conventional single-passage CLS. As part of this thesis, a MIRACLS proof-of-principle apparatus has been constructed around an MR-ToF system, operating at ~1.5 keV beam energy, which has been upgraded for the purpose of CLS. The goal of this setup is to demonstrate the potential of the MIRACLS concept, to benchmark simulations that are employed to design a future device operating at 30 keV, and to further develop the technique. For this purpose, CLS measurements with ions of stable magnesium and calcium isotopes are performed. This data serves to characterise the performance of the new method, especially in terms of gain in sensitivity and measurement accuracy.
Ion traps such as Paul traps and MR-ToF (multi-reflection time-of-flight) devices are indispensable tools at radioactive ion beam facilities for the preparation of high-quality radioactive ion beams for subsequent experiments or for precise measurements of the properties of radioactive ions, such as nuclear binding energies or nuclear charge radii.
Within the work of this thesis, Doppler- and sympathetic cooling is implemented in a linear Paul-trap cooler-buncher enabling a reduction of the longitudinal emittance of radioactive ion beams resulting in a significant improvement of the ion beam quality. Moreover, a next-generation MR-ToF device is conceptualized in order to achieve isobaric pure beams with a higher ion intensity than state-of-the-art MR-ToF devices can provide. Once fully constructed and commissioned, it will operate at an unprecedented ion beam energy of 30 keV. Both of these advances are expected to become important for a wide range of experimental programs pursued at low-energy branches of RIB facilities ranging from fundamental symmetry studies, nuclear structure, rare isotope studies with antimatter, searches of physics beyond the standard model to material science and the production of medical isotopes.
The next-generation MR-ToF mass separator is based on MIRACLS’ 30-keV MR-ToF device for highly sensitive and high-resolution collinear laser spectroscopy. By storing the ions in the Multi Ion Reflection Apparatus for Collinear Laser Spectroscopy (MIRACLS), the same ion bunch is probed by a spectroscopic laser for thousands of times compared to a single passage in traditional collinear laser spectroscopy (CLS). Dedicated simulation studies show that the accuracy and resolution will be close to traditional single-passage CLS while the sensitivity is significantly enhanced. Hence, measurements of nuclear properties via fluorescence-based CLS of very rare radionuclides as well as highly sensitive and high-precision measurements of electron affinities via laser-photodetachment-threshold spectroscopy of negatively-charged (radioactive) ions will become possible.
First measurement campaigns employing MIRACLS’ 1.5-keV MR-ToF device confirm the outstanding boost in signal sensitivity and provide confidence in the application of the MIRACLS technique for the measurement of scarcely produced radioactive ions that have been so far beyond the reach of conventional techniques. Furthermore, the electron affinity of 35Cl was measured, which is in perfect agreement with the literature value. These measurements will serve as important benchmarks for modern atomic and nuclear theory, especially in its description of nuclear charge radii.
In summary, the implementation of Doppler and sympathetic cooling at RIB facilities, the conceptualization of a 30-keV MR-ToF apparatus for highly selective and high-flux mass separation as well as for highly sensitive and high-resolution fluorescence-based laser spectroscopy and the expansion of the MIRACLS technique for the study of negatively-charged ions will enable unprecedented new measurement opportunities at RIB facilities.
Research into nuclear physics has enjoyed a long and rich history since the earliest experiments began investigating atomic constituents. The discovery of the atomic nucleus in the early 20th century started a complex field of research that has undergone many transformations with the advancements of modern technology. Today, atomic nuclei are not only studied to advance our understanding of the strong force but also to gain more information on the synthesis of elements in the universe, to exploit nuclear decay to investigate the weak interaction, and to search for physics beyond the standard model.
In this work, we will study the strong force in atomic nuclei, i.e. the way nucleons (protons and neutrons) arrange themselves in a many-body system governed by the repulsive Coulomb interaction and the attractive strong interaction. In particular, we will focus on nuclear structure near nuclei with a "magic number" of Z protons and N neutrons, so-called doubly-magic nuclei, exhibiting a particularly stable configuration with respect to neighboring nuclei.
Within the nuclear shell model, similar to the atomic shells, the magic numbers indicate shell closures accompanied by energy gaps. Nuclei at double-shell closures and their direct vicinity provide an important playground to benchmark nuclear theories and models that aim to predict the intricate interplay of the nucleons that lead to enhanced nuclear binding energies, significant changes in charge radii and transition strengths, etc.
Of particular interest are nuclear isomers, long-lived excited states, in which the nucleon configuration with respect to its ground state is altered, resulting in a modification of their properties despite having the same number of protons and neutrons.
The main part of this work consists of three publications, which report on nuclear structure investigations through mass measurements and laser spectroscopy near the doubly magic nuclei nickel-78, tin-100, and lead-208.
The nuclides investigated in this work include neutron-deficient indium isotopes, neutron-rich zinc isotopes, and neutron-rich mercury isotopes.
This thesis describes mass measurements at ISOLTRAP/ISOLDE/CERN in the region of the neutron-rich calcium isotopes. For the less exotic and more abundantly produced isotopes 51Ca and 52Ca the Penning trap based ToF-ICR technique could be used to validate the available mass data and to improve their precision. For the isotopes 53Ca and 54Ca, a Multi-Reflection Time-of-Flight Mass Spectrometer (MR-ToF MS) was used to determine the mass of these exotic isotopes for the first time experimentally. This also represents the first time an MR-ToF MS was applied to derive the masses of previously unknown radioactive ions from the high precision time-of-flight data that can be gathered with the device. The mass data was then used to benchmark the strength of the N=32 neutron subshell closure and at the same time to compare to state-of-the-art shell-model calculations.
Furthermore, the capability of the MR-ToF device to deliver isobarically pure beams to a subsequent experiment was developed further and studied in detail. The new technique is based on the in-trap lift, which is normally used to in- and eject ions into and from the device. With this new selective ejection technique after separation of the ion ensemble in the MR-ToF trap, no external components are required.
Additionally, a new stabilization system for voltages supplies, based on a PI-algorithm, was developed and thoroughly tested. The stabilized voltage supply was then used to supply the most sensitive mirror voltage of the MR-ToF MS to significantly increase the short term and long-term mass resolving power of the apparatus.