Refine
Year of publication
Document Type
- Doctoral Thesis (47)
- Article (1)
Has Fulltext
- yes (48)
Is part of the Bibliography
- no (48)
Keywords
- Okklusion (5)
- Zahnmedizin (5)
- occlusion (4)
- CEREC-System (3)
- Reproduzierbarkeit (3)
- SHIP (3)
- CAD-CAM (2)
- Computertomographie (2)
- Dentalkeramik (2)
- Doppelkrone (2)
- Elongation (2)
- Evaluation (2)
- Keramik (2)
- Konuskrone (2)
- Metallkeramik (2)
- NMR-Tomographie (2)
- OHIP (2)
- Zahnokklusion (2)
- Zahnverlust (2)
- Zufriedenheit (2)
- - (1)
- 4188049-3 (1)
- ARCUSdigma (1)
- Abformung (1)
- Abrasiver Verschleiß (1)
- Alginate (1)
- Alter (1)
- Alterszahnmedizin (1)
- Anthropometrie (1)
- Artefakte (1)
- Artikulator (1)
- Aufstellung <Zahntechnik> (1)
- Balkwill Angle (1)
- Balkwill-Winkel (1)
- Benchmarking (1)
- Beryllium (1)
- Beryllium-Toxizität (1)
- Bewegungsregistrierung (1)
- Bewegungsverhalten (1)
- Biegefestigkeit (1)
- Biokompatibilität (1)
- Bissregistrierung (1)
- Body-Mass-Index (1)
- Brenngutträger (1)
- CEREC Omnicam (1)
- CMD (1)
- Cerec 3D (1)
- Chairside (1)
- Chairside Herstellung (1)
- Craniomandibular (1)
- Craniomandibulär (1)
- Dental (1)
- Dentallegierung (1)
- Desinfektion (1)
- Desinfektionsmittel (1)
- Digitale Okklusion (1)
- Digitale Zahnmedizin (1)
- Dimension (1)
- Dissertation (1)
- Doppelkronen (1)
- Eckzahnführung (1)
- Ernährung (1)
- FH plane (1)
- Farbe (1)
- Finite-Elemente-Analyse (1)
- Folgekosten (1)
- Fragebogen (1)
- Funktionsanalyse (Zahnmedizin) (1)
- GEDAS (Greifswald Digital Analyzing System) (1)
- Gesichtsschädel (1)
- Gesundheitsökonomie (1)
- Haftverbund (1)
- Haltezeit (1)
- Haltung (1)
- Helligkeit (1)
- Herstellungsverfahren (1)
- Hohlkehle (1)
- Hohlschliff (1)
- Höckerneigung (1)
- Höckerwinkel (1)
- IPR (1)
- Immersionstest (1)
- Implantat Design (1)
- Implantatstabilität (1)
- Implantatüberleben (1)
- In vivo Studie (1)
- In vivo Study (1)
- Intraklassenkorrelation (1)
- JAW-Motion-Analyser (1)
- Jaw Motion Analyzer (1)
- Kaubewegung (1)
- Kaufläche (1)
- Kaufunktion (1)
- Kaumuster (1)
- Keramikmassen (1)
- Kieferrelation (1)
- Kippung (1)
- Kobalt-Chrom-Molybdän (Co-Cr-Mo) (1)
- Komposite (1)
- Kontaktflächenmuster (1)
- Konuskronenprothesen (1)
- Koordination (1)
- Kosten (1)
- Laser (1)
- Laserparameter (1)
- Legierung (1)
- Lichtdurchlässigkeit (1)
- Lösekraft (1)
- MRI (1)
- Mastikation (1)
- Mesostruktur (1)
- Metall (1)
- Mini Dental Implants (1)
- Miniimplantat (1)
- Mundbezogene Lebensqualität (1)
- Nickellegierung (1)
- Normierung (1)
- Oberfläche (1)
- Oberflächengüte (1)
- Oberflächenqualität (1)
- Oberflächenrauhigkeit (1)
- Okklusales Settling (1)
- Okklusionsfläche (1)
- Okklusionskonzept (1)
- Opazität (1)
- Oralchirurgie (1)
- Overerution (1)
- Periotest (1)
- Pfeilervermehrung (1)
- Plaque (1)
- Potentiodynamische Korrosionsuntersuchung (1)
- Probekörper (1)
- Prothese (1)
- Prothesenreinigung (1)
- Prothetik (1)
- Prävention (1)
- Qualitдtsmanagement (1)
- Quality management (1)
- Questionnaire (1)
- Rater Agreement (1)
- Registrierung (1)
- Reliability (1)
- Reliabilität (1)
- Reproducibility (1)
- Resonanzfrequenzanalyse (1)
- Rotation (1)
- SHIP 1 (1)
- Schaltlücke (1)
- Schlifffacetten (1)
- Schrumpfung (1)
- Seitenzahnlücke (1)
- Selbstbeobachtung (1)
- Self-observation (1)
- Seniorenmundgesundheit (1)
- Settling (1)
- Sintering protocols (1)
- Sinterparameter (1)
- Sinterprozess (1)
- Sintertemperatur (1)
- Soziale Situation (1)
- Split-Mouth (1)
- Standardization (1)
- Statische Okklusion (1)
- Teilprothese (1)
- Teilprothesen (1)
- Teleskopkrone (1)
- Temperatur (1)
- Titan (1)
- Tooth (1)
- Totale Zahnprothese (1)
- Totalprothese (1)
- Transparenz (1)
- Urteilerübereinstimmung (1)
- Verblendkeramik (1)
- Verblendung (1)
- Vergleich Okklusion (1)
- Vergleichsstudie (1)
- Verschleiß (1)
- Virtuelle Zahnmedizin (1)
- Vollkeramik (1)
- Vollkeramikbrücken (1)
- Zahn (1)
- Zahnimplantat (1)
- Zahnstabilität (1)
- Zahnzahl (1)
- Zellen (1)
- Zentrik (1)
- Zirkoniumdioxid (1)
- Zirkonoxidkeramik (ZrO2) (1)
- Zuverlässigkeit (1)
- ambulante Pflege (1)
- antagonistenlose Zähne (1)
- artefacts (1)
- articulator (1)
- atomabsorptionsspectroscopy (1)
- beryllium-toxicity (1)
- biocompatibility (1)
- bite registration (1)
- canine guidance (1)
- centric condylar positioning (1)
- ceramic (1)
- ceramic fixed dental prosthesis (1)
- chairside (1)
- chairside crafted (1)
- chewing motion (1)
- chewing pattern (1)
- cobalt chrome molybdenum (Co-Cr-Mo) (1)
- colour (1)
- comparison occlusion (1)
- composites (1)
- computergestütztes Unterkiefertraining (1)
- contact surface pattern (1)
- contraction (1)
- corrosion rate (1)
- cusp inclination (1)
- delay (1)
- denture (1)
- digital bite registration (1)
- digital occlusion (1)
- digitale Bissregistrierung (1)
- double-crown system (1)
- edentulos (1)
- epidemiologische Studien (1)
- firing tray (1)
- fullceramic (1)
- herausnehmbaren Zahnersatz (1)
- holding force (1)
- inductivelely coupled plasma - atomic emission (1)
- ion release (1)
- jaw motion (1)
- konventionelle Bissregistrierung (1)
- kraniomandibuläre Bewegungsabläufe (1)
- laser (1)
- laser welding (1)
- leucit ceramics (1)
- lightness (1)
- longitudinal cohort study (1)
- low fusing ceramics (1)
- manufacturing technology (1)
- masticatory funktion (1)
- mesostructure (1)
- metal ceramics (1)
- metal-ceramic (1)
- motion tracking (1)
- multilayer Zirkoniumdioxid (1)
- occlusal concept (1)
- occlusal settling (1)
- occlusal surface (1)
- occlusal wear (1)
- parameter (1)
- phenotyping (1)
- population-based imaging (1)
- potentiodynamic corrosion testing (1)
- prosthesis (1)
- radiomics (1)
- removable dental prostheses (1)
- rotation (1)
- satisfaction (1)
- settling (1)
- shrinkage (1)
- single-tooth gaps (1)
- sinter-process (1)
- sintering (1)
- soldering (1)
- static occlusion (1)
- surface roughness (1)
- telescopic crown (1)
- temperature (1)
- tipping (1)
- tooth loss (1)
- verengt (1)
- virtual articulator (1)
- virtual dentistry (1)
- virtueller Artikulator (1)
- voltage (1)
- welding (1)
- whole-body magnetic resonance imaging (1)
- zahnlos (1)
- zentrische Kondylenposition (1)
- zirconium oxide ceramic (ZrO2) (1)
Institute
- Poliklinik für zahnärztliche Prothetik und Werkstoffkunde (48) (remove)
Publisher
- MDPI (1)
Ziel dieser Studie ist es, die Auswirkungen von verschiedenen Desinfektionsmittel auf die Dimensionsstabilität von dentalen Abformmaterialien zu zeigen.
Hierfür werden mit den Alginaten Blueprint Xcreme (Fa. Dentsply Sirona) und HS-Maxima (Fa. Henry Schein) unter Zuhilfenahme der Material- Prüfmaschine RetroLine Z050 TH (Fa. ZwickRoell) in einem standardisierten Verfahren Abformungen von einem in Nichtedelmetall gegossenen Meistermodell genommen. Diese unbehandelten Abformungen werden mit dem Meistermodell verglichen. In einer zweiten Versuchsreihe werden Abformungen mit den Desinfektionsmitteln ORBI-Sept (Fa. Orbis), Zeta 90+ (Fa. Zhermack), MD 520 (Fa. Dürr Dental), Dentavon (Fa. Schülke) und EuroSept Plus (Fa. Henry Schein) behandelt und mit den unbehandelten Referenzabformungen verglichen. Es wurde in einer dritten Versuchsreihe auch der Einfluss der Körpertemperatur getestet. Hierfür wurde das Meistermodell unmittelbar vor der Abformung in einem Wasserbad auf 36 Grad Celsius Mundtemperatur erwärmt. Für die Vermessung werden vier Messpunkte auf dem Meistermodell festgelegt und mit A, B, C und D bezeichnet. Mit dem Messmikroskop Measuring Microscope STM (Fa. Olympus) wurden die Strecken [AB], [BC], [CD], [AD] und [BD] in den Alginatabformungen unverzüglich nach Entformung, beziehungsweise nach der Behandlung mit Desinfektionsmittel, gemessen.
In den Ergebnissen zeigt sich, dass zwischen dem Meistermodell und den unbehandelten Referenzabformungen, den Abformungen bei Raum- und Mundtemperatur und im Vergleich der mit Desinfektionsmittel behandelten mit den nicht behandelten Abformungen signifikante Unterschiede nachzuweisen sind.
Bei Betrachtung der relativen, als auch der absoluten Werte der nachgewiesenen Unterschiede zeigt sich jedoch, dass alle Werte in einem klinisch akzeptablen Bereich liegen.
Die verwendeten Desinfektionsmittel haben einen Einfluss auf die Dimension der Alginate, diese sind jedoch so gering, dass sie im klinischen Alltag vernachlässigbar sind.