The EyeFlowCell: Development of a 3D-Printed Dissolution Test Setup for Intravitreal Dosage Forms
(2021)
An in vitro dissolution model, the so-called EyeFlowCell (EFC), was developed to test intravitreal dosage forms, simulating parameters such as the gel-like consistency of the vitreous body. The developed model consists of a stereolithography 3D-printed flow-through cell with a polyacrylamide (PAA) gel as its core. This gel needed to be coated with an agarose sheath because of its low viscosity. Drug release from hydroxypropyl methylcellulose-based implants containing either triamcinolone acetonide or fluorescein sodium was studied in the EFC using a schematic eye movement by the EyeMovementSystem (EyeMoS). For comparison, studies were performed in USP apparatus 4 and USP apparatus 7. Significantly slower drug release was observed in the PAA gel for both model drugs compared with the compendial methods. Drug release from fluorescein sodium-containing model implants was completed after 40 min in USP apparatus 4, whereas drug release in the gel-based EFC lasted 72 h. Drug release from triamcinolone acetonide-containing model implants was completed after 35 min in USP apparatus 4 and after 150 min in USP apparatus 7, whereas this was delayed until 96 h in the EFC. These results suggest that compendial release methods may overestimate the drug release rate in the human vitreous body. Using a gel-based in vitro release system such as the EFC may better predict drug release.
Controlling the time point and site of the release of active ingredients within the gastrointestinal tract after administration of oral delivery systems is still a challenge. In this study, the effect of the combination of small capsules (size 3) and large capsules (size 00) on the disintegration site and time was investigated using magnetic resonance imaging (MRI) in combination with a salivary tracer technique. As capsule shells, Vcaps® HPMC capsules, Vcaps® Plus HPMC capsules, gelatin and DRcaps® designed release capsules were used. The three HPMC-based capsules (Vcaps®, Vcaps® Plus and DRcaps® capsules) were tested as single capsules; furthermore, seven DUOCAP® capsule-in-capsule combinations were tested in a 10-way crossover open-label study in six healthy volunteers. The capsules contained iron oxide and hibiscus tea powder as tracers for visualization in MRI, and two different caffeine species (natural caffeine and 13C3) to follow caffeine release and absorption as measured by salivary levels. Results showed that the timing and location of disintegration in the gastrointestinal tract can be measured and differed when using different combinations of capsule shells. Increased variability among the six subjects was observed in most of the capsule combinations. The lowest variability in gastrointestinal localization of disintegration was observed for the DUOCAP® capsule-in-capsule configuration using a DRcaps® designed release capsule within a DRcaps® designed release outer capsule. In this combination, the inner DRcaps® designed release capsule always opened reliably after reaching the ileum. Thus, this combination enables targeted delivery to the distal small intestine. Among the single capsules tested, Vcaps® Plus HPMC capsules showed the fastest and most consistent disintegration.
Abstract
Saliva is an attractive sampling matrix for measuring various endogenous and exogeneous substances but requires sample treatment prior to chromatographic analysis. Exploiting supercritical CO2 for both extraction and chromatography simplifies sample preparation, reduces organic solvent consumption, and minimizes exposure to potentially infectious samples, but has not yet been applied to oral fluid. Here, we demonstrate the feasibility and benefits of online supercritical fluid extraction coupled to supercritical fluid chromatography and single‐quadrupole mass spectrometry for monitoring the model salivary tracer caffeine. A comparison of 13C‐ and 32S‐labeled internal standards with external standard calibration confirmed the superiority of stable isotope‐labeled caffeine over nonanalogous internal standards. As proof of concept, the validated method was applied to saliva from a magnetic resonance imaging study of gastric emptying. After administration of 35 mg caffeine via ice capsule, salivary levels correlated with magnetic resonance imaging data, corroborating caffeine's usefulness as tracer of gastric emptying (R2 = 0.945). In contrast to off‐line methods, online quantification required only minute amounts of organic solvents and a single manual operation prior to online bioanalysis of saliva, thus demonstrating the usefulness of CO2‐based extraction and separation techniques for potentially infective biomatrices.
The microbiome of the colon is characterized by its great diversity. This varies not only intra- but also interindividually and is influenced by endogenous and exogenous factors, such as dietary and lifestyle factors. The aim of this work was to investigate the extent to which the degradation of the drug sulfasalazine is influenced by different microbiota. Therefore, the in vitro model MimiCol3 was used, which represents the physiological conditions of the ascending colon. In addition to a representative physiological volume, the pH value, redox potential and an anaerobic atmosphere are important to provide the bacteria with the best possible growth conditions. Stool samples were taken from three healthy subjects, comparing omnivorous, vegetarian and meat-rich diets, and cultured for 24 h. However, the nutrient medium used for cultivation led to the alignment of the bacterial composition of the microbiota. The previously observed differences between the diets could not be maintained. Nevertheless, the similar degradation of sulfasalazine was observed in all microbiota studied in MimiCol3. This makes MimiCol3 a suitable in vitro model for metabolism studies in the gut microbiome.
Postoperative restenosis in patients with external ear canal (EEC) atresia or stenosis is a common complication following canaloplasty. Our aim in this study was to explore the feasibility of using a three dimensionally (3D)-printed, patient-individualized, drug ((dexamethasone (DEX)), and ciprofloxacin (cipro))-releasing external ear canal implant (EECI) as a postoperative stent after canaloplasty. We designed and pre-clinically tested this novel implant for drug release (by high-performance liquid chromatography), biocompatibility (by the MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) assay), bio-efficacy (by the TNF-α (tumor necrosis factor-alpha)-reduction test (DEX) and inhibition zone test (for cipro)), and microbial contamination (formation of turbidity or sediments in culture medium). The EECI was implanted for the first time to one patient with a history of congenital EEC atresia and state after three canaloplasties due to EEC restenosis. The preclinical tests revealed no cytotoxic effect of the used materials; an antibacterial effect was verified against the bacteria Staphylococcus aureus and Pseudomonas aeruginosa, and the tested UV-irradiated EECI showed no microbiological contamination. Based on the test results, the combination of silicone with 1% DEX and 0.3% cipro was chosen to treat the patient. The EECI was implantable into the EEC; the postoperative follow-up visits revealed no otogenic symptoms or infections and the EECI was explanted three months postoperatively. Even at 12 months postoperatively, the EEC showed good epithelialization and patency. Here, we report the first ever clinical application of an individualized, drug-releasing, mechanically flexible implant and suggest that our novel EECI represents a safe and effective method for postoperatively stenting the reconstructed EEC.
Many orally dosed APIs are bioavailable only when formulated as an enteric dosage form to protect them from the harsh environment of the stomach. However, an enteric formulation is often accompanied with a higher development effort in the first place and the potential degradation of fragile APIs during the coating process. Ready-to-use enteric hard capsules would be an easily available alternative to test and develop APIs in enteric formulations, while decreasing the time and cost of process development. In this regard, Lonza Capsugel® Next Generation Enteric capsules offer a promising approach as functional capsules. The in vivo performance of these capsules was observed with two independent techniques (MRI and caffeine in saliva) in eight human volunteers. No disintegration or content release in the stomach was observed, even after highly variable individual gastric residence times (range 7.5 to 82.5 min), indicating the reliable enteric properties of these capsules. Seven capsules disintegrated in the distal part of the small intestine; one capsule showed an uncommonly fast intestinal transit (15 min) and disintegrated in the colon. The results for this latter capsule by MRI and caffeine appearance differed dramatically, whereas for all other capsules disintegrating in the small intestine, the results were very comparable, which highlights the necessity for reliable and complementary measurement methods. No correlation could be found between the gastric residence time and disintegration after gastric emptying, which confirms the robust enteric formulation of those capsules.
: An enhanced indoleamine 2,3-dioxygenase 1 (IDO1) activity is associated with an increased
mortality risk in sepsis patients. Thus, the preventive inhibition of IDO1 activity may be
a promising strategy to attenuate the severity of septic shock. 1-methyltryptophan (1-MT)
is currently in the interest of research due to its potential inhibitory effects on IDO1 and
immunomodulatory properties. The present study aims to investigate the protective and
immunomodulatory effects of 1-methyltryptophan against endotoxin-induced shock in a porcine
in vivo model. Effects of 1-MT were determined on lipopolysaccharide (LPS)-induced tryptophan
(TRP) degradation, immune response and sickness behaviour. 1-MT increased TRP and its metabolite
kynurenic acid (KYNA) in plasma and tissues, suppressed the LPS-induced maturation of neutrophils
and increased inactivity of the animals. 1-MT did not inhibit the LPS-induced degradation of TRP
to kynurenine (KYN)—a marker for IDO1 activity—although the increase in KYNA indicates that
degradation to one branch of the KYN pathway is facilitated. In conclusion, our findings provide
no evidence for IDO1 inhibition but reveal the side effects of 1-MT that may result from the proven
interference of KYNA and 1-MT with aryl hydrocarbon receptor signalling. These effects should be
considered for therapeutic applications of 1-MT.
Development of Test Programs for the Biorelevant Characterization of Esophageal-Applied Dosage Forms
(2023)
In the local treatment of the esophageal mucosa, the retention time of the different dosage forms, such as tablets, films or liquids, is of high relevance for the effective treatment of diseases. Unfortunately, there are only few in vitro models describing the esophageal route of administration. To predict the behaviour of an esophageal-applied dosage form, it is necessary to simulate the site of application in a biorelevant way. The aim of this work was to develop two test setups for an esophageal peristalsis model which was described in a previous study. Different parameters such as flow rate, peristalsis, angle of inclination or mucous membrane were varied or introduced into the model. A stimulated and unstimulated modus were developed and tested with two different dosage forms. The time until the dosage form was cleared from the in vitro model was shorter with the stimulated than with the unstimulated modus. Also, esophageal-applied films had a prolonged transit time compared to a viscous syrup. The modification of the simulated esophageal surface made it possible to estimate the retention time of the dosage forms. It could be demonstrated that the residence time of a dosage form depends on different parameters affecting each other.
Fibers and yarns are part of everyday life. So far, fibers that are also used pharmaceutically have mainly been produced by electrospinning. The common use of spinning oils and the excipients they contain, in connection with production by melt extrusion, poses a regulatory challenge for pharmaceutically usable fibers. In this publication, a newly developed small-scale direct-spinning melt extrusion system is described, and the pharmaceutically useful polyvinyl filaments produced with it are characterized. The major parts of the system were newly developed or extensively modified and manufactured cost-effectively within a short time using rapid prototyping (3D printing) from various materials. For example, a stainless-steel spinneret was developed in a splice design for a table-top melt extrusion system that can be used in the pharmaceutical industry. The direct processing of the extruded fibers was made possible by a spinning system developed called Spinning-Rosi, which operates continuously and directly in the extrusion process and eliminates the need for spinning oils. In order to prevent instabilities in the product, further modifications were also made to the process, such as a the moisture encapsulation of the melt extrusion line at certain points, which resulted in a bubble-free extrudate with high tensile strength, even in a melt extrusion line without built-in venting.