Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed.
Methods
THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted.
Results
No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden.
Conclusion
Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.
Unlike the native surface of the implant material (Ti6Al4V), oxidation with H2O2 leads to increased binding of the effective antimicrobial agent poly(hexamethylene) biguanide [PHMB]. However, treating with NaOH instead results in an even higher PHMB mass coverage. After oxidation with H2O2, strong differences in the PHMB adsorption capability between polished and corundum-blasted surfaces appear, indicating a roughness dependence. After NaOH treatment, no such effect was observed. The wetting properties of specimens treated with either H2O2 or NaOH prior to PHMB exposure clearly varied. To unravel the nature of this interaction, widespread in silico and in vitro experiments were performed. Methods: By X-ray photoelectron spectroscopy, scanning electron microscopy, water contact angle measurements and MD simulations, we characterized the interplay between the polycationic antimicrobial agent and the implant surface. A theoretical model for PHMB micelles is tested for its wetting properties and compared to carbon contaminated TiO2. In addition, quantitation of anionic functional group equivalents, the binding properties of PHMB with blocked amino end-group, and the ability to bind chlorhexidine digluconate (CHG) were investigated. Ultimately, the capability of osteoblasts to build calcium apatite, and the activity of alkaline phosphatase on PHMB coated specimens, were determined. Results: Simulated water contact angles on carbon contaminated TiO2 surfaces and PHMB micelle models reveal little influence of PHMB on the wetting properties and point out the major influence of remaining and recovering contamination from ambient air. Testing PHMB adsorption beyond the critical micelle concentration and subsequent staining reveals an island-like pattern with H2O2 as compared to an evenly modified surface with NaOH. Both CHG and PHMB, with blocked amino end groups, were adsorbed on the treated surfaces, thus negating the significant influence of PHMB’s terminal groups. The ability of osteoblasts to produce calcium apatite and alkaline phosphatase is not negatively impaired for PHMB mass coverages up to 8 μg/specimen. Conclusion: Differences in PHMB adsorption are triggered by the number of anionic groups and carbon contaminants, both of which depend on the specimen pre-treatment. With more PHMB covering, the implant surface is protected against the capture of new contamination from the ambient air, thus building a robust antimicrobial and biocompatible surface coating.
Abstract
Antimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant‐associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H2O2 for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self‐assembled PHMB layer. Compared with an untreated control group, adsorbed PHMB produces no adverse effects on SaOs‐2 cells within 48 hr cell culture, but promotes the initial attachment and spreading of the osteoblasts within 15 min. Specimens were inoculated with slime‐producing bacteria to simulate a perioperative infection. Adsorbed PHMB reacts bactericidally against Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa after surface contact. Adhered SaOs‐2 cells differentiate and produce alkaline phosphatase and deposit calcium within 4 days in a mineralization medium on PHMB‐coated Ti6Al4V surfaces, which have been precontaminated with S. epidermidis. The presented procedures provide a simple method for generating biocompatibly and antimicrobially effective implant surfaces that may be clinically important.
Ziel dieser Arbeit war der Nachweis der antimikrobielle Wirksamkeit von oberflächlich, durch einfache chemische Verfahren immobilisiertem PHMB auf Ti6Al4V-Oberflächen gegenüber Gram-positiven und Gram-negativen Erregern mit Standardmethoden und methodischen Varianten.
Die Immobilisierung von PHMB auf Ti6Al4V-Oberflächen erfolgte entweder oxidativ durch die Behandlung der Prüfkörper mit 5 % H2O2 oder über eine alkalische Hydrolyse in 5 M NaOH-Lösung. Als Prüfmikroorganismen dienten die Gram-positiven Schleimbildner S. aureus (ATCC 29213/DSM 2569) und S. epidermidis (ATCC 35984/DSM 28319), als Gram-negativer Vertreter P. aeruginosa (ATCC 27853/DSM 1117). Die Biofilmbildungsintensitäten der eingesetzten Erreger wurden nach Anwendung der Kristallviolett-Färbemethode (Fletcher 1977) quantifiziert. Die Ermittlung der antimikrobiellen Wirksamkeit von PHMB-beschichteten Prüfkörpern erfolgte durch quantitative bzw. qualitative Methoden. Dafür wurden zwei Strategien verfolgt: (1) Herstellung des unmittelbaren Kontakts zwischen Mikroorganismen und antimikrobieller Oberfläche durch Verringerung des Flüssigkeitsvolumens des Kulturmediums mittels Vakuum- oder Wärmebehandlung; und (2) Untersuchung des Adhärenzverhaltens der Mikroorganismen nach 15 min und/oder 6 h Kontakt mit der PHMB-Beschichtung der Ti6Al4V-Prüfkörper. Die Etablierung eines ATP-Tests zur quantitativen Bestimmung der Bakterien war ebenfalls Bestandteil der Untersuchungen zur antimikrobiellen Wirksamkeit. Qualitativ erfolgte die Auswertung mit Hilfe von LIVE/DEAD-Färbungen und des CASO-Agar-Overlay-Tests. Die Validierung der effektiven mikrobioziden Wirksamkeit gegenüber S. epidermidis erfolgte in Co-Kultur-Versuchen mit den Osteoblasten-ähnlichen SaOs-2-Zellen.
Während die Kultivierung von S. aureus und P. aeruginosa im verwendeten Zellkulturmedium DMEM/F12 möglich war, tolerierte S. epidermidis das Medium nicht. Die Entwicklung eines Co-Kulturmediums, bestehend aus 10 % CASO-Bouillon und 90 % Zellkulturmedium, ermöglichte sowohl das Wachstum der Bakterienspecies als auch das der SaOs-2 Zellen, was eine wichtige Voraussetzung für weiterführende Co-Kulturen war. Die Produktion eines Biofilms konnte bei allen Erregern mittels Kristallviolett-Färbung nachgewiesen werden. Nach Herstellung des direkten Kontaktes zwischen den Prüfmikroorganismen und der antimikrobiellen Oberfläche durch Reduzierung des Flüssigkeitsvolumens der applizierten Bakteriensuspensionen, resultierten Reduktionsraten von 3 – 5 log10 für S. aureus und S. epidermidis. Der Gram-negative Erreger P. aeruginosa ist hingegen mit nur 0,5 – 1,5 log10-Stufen Reduktion für diese Methoden als ungeeignet einzustufen ist, da ein Absterben des Erregers aufgrund von Austrocknung nicht auszuschließen war. Die Adhärenz der eingesetzten Mikroorganismen nach 15 min Kontaktzeit und anschließender Inkubation bei 37 °C für 6 h, resultierte in Reduktionsraten von 4 – 5 log10 für S. aureus, 1 – 5 log10 für P. aeruginosa und 3 – 4 log10 für S. epidermidis. Mit PHMB beschichtete Ti6Al4V-Prüfkörper, die in einer Bakteriensuspension für 6 h unter dynamischen Bedingungen inkubiert wurden, zeigten nur Reduktionsraten von ca. 1 – 3 log10-Stufen gegenüber den Testbakterien. Nach 15 min Kontaktzeit auf einer kontaminierte Agar-Oberfläche und weiteren 6 h Inkubation bei 37 °C, konnten auf antimikrobiellen PHMB-Oberflächen Reduktionen von 1 – 2 log10-Stufen ermittelt werden. In angewandten Co-Kulturtests mit S. epidermidis und SaOs-2 Zellen konnte die antimikrobielle Wirksamkeit der PHMB-beschichteten Oberfläche bestätigt werden.
Die antimikrobiell wirksame PHMB-Schicht auf den eingesetzten Ti6Al4V-Prüfkörpern benötigt zur Abtötung von Erregern den direkten Kontakt zwischen der Oberfläche und den Prüfmikroorganismen, um wirksam zu sein. Zudem konnte ermittelt werden, dass PHMB ausschließlich auf der Oberseite der Prüfkörper immobilisiert werden konnte, was die Mikrobiozidie-Testung mit herkömmlichen Methoden erschwert.
Es konnte bestätigt werden, dass oberflächlich immobilisiertes PHMB auf Ti6Al4V-Prüfkörpern sowohl Gram-positive als auch Gram-negative Bakterien bei direktem Kontakt abtötet. Als am besten geeignet für die Testung dieser Oberfläche erwies sich die 6 h-Adhärenz-Methode, bei der nach 6 h oberflächlichem Kontakt quantitativ und qualitativ keine überlebenden Mikroorganismen nachgewiesen werden konnten.