In this work, studies with respect to the exhaust problem were performed
in the stellarator experiment Wendelstein 7-X with different target concepts and different magnetic field geometries. Different infrared cameras were used to study the heat flux from the plasma onto the PFC. In the first publication, the limiter set-up was used with a simpler magnetic topology in the plasma edge. The radial fall-off of the parallel heat flux for inboard limiters in W7-X shows, similar to inboard limiters in tokamaks, two different radial fall-off lengths, a short (narrow) one, characterizing the near-SOL, and a long (broad) characterizing the far-SOL. For the far-SOL, the heating power and connection length have been identified as the main scaling parameters, while for the near-SOL, the electron temperature close to the LCFS has been identified as the main scaling parameter. The two fall-off lengths differ by a factor 10, and the found scalings for both regimes differ from known models and experimental scalings in tokamaks. A turbulent-driven feature was discussed in the publication as a possible explanation for the behavior of the fall-off length in W7-X.
The gained information and data have been further used to support many
other publications, covering the symmetry of the heat loads, the
energy balance of the machine, and seeding experiments.
The heat exhaust in W7-X with an island divertor was studied in the second
and third publication. Definitions of parameters such as peaking factor and
wetted area were applied for the heterogeneous heat flux pattern on the
W7-X divertor. It was shown that the island divertor concept is capable
of spreading out the heat efficiently, resulting in large wetted areas of up to 1.5 m2. The reached values for the wetted area are comparable to the ones of the larger tokamak JET but with a much smaller ratio of wetted
area to the area of the last closed flux surface. Furthermore, a positive
scaling of the wetted area with the power in the SOL was observed. This
scaling is beneficial for future reactors but needs further investigation of the involved transport processes. The peaking factor (discussed in the second publication) describes how concentrated the heat load is within the region of the strike line. It was shown that this factor is decreasing for increasing densities without affecting the wetted area. The present work paves the way for further analysis of the transport processes of the heat flux towards the island divertor of Wendelstein 7-X.
Lipohypertrophien (LHT) sind Veränderungen des subkutanen Fettgewebes, die durch die Langzeitanwendung von Insulin bei ca. 40 % der Patienten entstehen. Sie waren bisher von fraglicher klinischer Relevanz und teilweise schwierig zu diagnostizieren. Die Veröffentlichungen im Rahmen dieser kumulativen Dissertation untersuchten die pharmakotherapeutische Bedeutung von Lipohypertrophien und untersuchten erstmals die Thermographie als diagnostische Option für LHT. Dabei zeigte sich im euglykämischen Clamp-Versuch eine signifikant reduzierte Bioverfügbarkeit des Insulins nach Injektion in LHT von 78-80 % im Vergleich zur Applikation in gesundes Gewebe. Zwei der dreizehn Probanden zeigten keine Insulinwirkung. Die intraindividuelle Variabilität war signifikant höher in LHT als im gesunden Gewebe. Bei der erstmaligen systematischen Untersuchung von LHT mit einer hochwertigen Wärmebildkamera zeigte sich eine mäßige diagnostische Güte, verglichen mit den ebenfalls teilweise schwierigen Methoden der Inspektion, Palpation und des Ultraschalls. Insbesondere in der Kontrollgruppe war eine klare Abgrenzung von gesundem Gewebe schwierig. Aufgrund der Beeinflussung der Sicherheit, Effektivität und der Effizienz der Pharmakotherapie durch LHT, sollten diese als Injektionsort vermieden werden. Diese Arbeit konnte den Nutzen der Thermographie als diagnostische Option bei LHT zwar nicht klar beweisen, jedoch diesen auch nicht ausschließen.