Refine
Year of publication
Document Type
- Doctoral Thesis (121)
- Article (30)
Has Fulltext
- yes (151)
Is part of the Bibliography
- no (151)
Keywords
- - (25)
- Händedesinfektion (15)
- Hygiene (10)
- Polihexanid (10)
- Antiseptik (9)
- Chlorhexidin (7)
- Wundinfektion (7)
- MRSA (6)
- Plasma (6)
- Atmosphärendruckplasma (5)
- Bakterien (5)
- Biofilm (5)
- Octenidin (5)
- PHMB (5)
- plasma medicine (5)
- Antiseptikum (4)
- Desinfektion (4)
- Handschuh (4)
- Haut (4)
- Hautschutz (4)
- Infektion (4)
- Krankenhaushygiene (4)
- Resorption (4)
- Wunde (4)
- Zahnmedizin (4)
- hygiene (4)
- Aufbereitung (3)
- CAP (3)
- Cytotoxizität (3)
- Desinfektionsmittel (3)
- Iod (3)
- Povidon-Iod (3)
- Prüfkörpertest (3)
- SSI (3)
- Silber (3)
- antibiotics (3)
- antiseptics (3)
- chronic wounds (3)
- compliance (3)
- reactive oxygen and nitrogen species (3)
- surgical site infection (3)
- Antibiotika (2)
- Antibiotikum (2)
- Antisepsis (2)
- Antiseptic (2)
- Antiseptic efficacy (2)
- Antiseptics (2)
- Antiserum (2)
- Arzneimittel (2)
- Belastung (2)
- Bettenaufbereitung (2)
- Biatain Ag (2)
- Büro (2)
- Dentaleinheit (2)
- Ethanol (2)
- Hautantiseptik (2)
- Hautpflege (2)
- Hospitalismus <Hygiene> (2)
- Händehygiene (2)
- Kaltes Plasma (2)
- Krankenhaus (2)
- Latex (2)
- Multidrug-Resistenz (2)
- Neugeborene (2)
- Nitrile (2)
- Octenidine dihydrochloride (2)
- Phosphatidylcholin (2)
- Plasmamedizin (2)
- Polihexanide (2)
- Propan-1-ol (2)
- Propanol (2)
- Prävention (2)
- Pseudomonas aeruginosa (2)
- RNS (2)
- ROS (2)
- Raumluft (2)
- Rettungswesen (2)
- Skin barrier (2)
- Staphylococcus aureus (2)
- Staphylococcus epidermidis (2)
- Stratum corneum (2)
- Tissue Tolerable Plasma (2)
- Wound (2)
- Wundheilung (2)
- Wundverband (2)
- Zahnarztpraxis (2)
- Zahnpflege (2)
- antisepsis (2)
- antiseptic stewardship (2)
- biocide (2)
- biofilm (2)
- cancer (2)
- chirurgische Händedesinfektion (2)
- chlorhexidine (2)
- chronic wound (2)
- chronische Wunden (2)
- cold physical plasma (2)
- contamination (2)
- cross-resistance (2)
- cross-tolerance (2)
- nosocomial infections (2)
- training (2)
- 2-Phenoxyethanol (1)
- 5 moments (1)
- Absorption (1)
- Acanthamoeba (1)
- Acetaldehyd (1)
- Actin (1)
- Actisorb Silver 220 (1)
- Agardiffusion (1)
- Agardilution (1)
- Age- and Sex-distribution (1)
- Aktin (1)
- Aktivkohle (1)
- Akzeptanz (1)
- Albumin (1)
- Alkoholabstinenznachweis (1)
- Alkohole (1)
- Alkoholresorption (1)
- Allergie (1)
- Allergisches Asthma (1)
- Aminobuttersäure <gamma-> (1)
- Analyse (1)
- Angewandte Mikrobiologie (1)
- Anodische Oxidation <Oberflächenbehandlung> (1)
- Anti-Plaque-Wirksamkeit (1)
- Antibiose (1)
- Antibiotika-assoziierte Colitis (1)
- Antibiotikaresistenzen (1)
- Antiinfektiva (1)
- Antimicrobial (1)
- Antimicrobial efficacy (1)
- Antimikrobielle Eigenschaft (1)
- Antioxidants (1)
- Antioxidatives Potential (1)
- Antiphlogistikum (1)
- Antiseptic mouth rinse (1)
- Antiseptika (1)
- Antiseptische Spülung (1)
- Antiseptische Wirksamkeit (1)
- Anästhesie (1)
- Apoptosis (1)
- Aquacel (1)
- Argonplasma (1)
- Arzneimittelwechselwirkung (1)
- Arzneistoffe (1)
- Asepsis (1)
- Atmospheric pressure plasma (1)
- Atmosphärendruck (1)
- Aufbereitungsformen (1)
- Augenantiseptik (1)
- Ausbildung (1)
- Bacteria (1)
- Bacterial vaginosis (1)
- Bakterizid (1)
- Barriere (1)
- Bauchfellentzündung (1)
- Behaarung (1)
- Benetzung (1)
- Berlin / Robert-Koch-Institut (1)
- Beschichtung (1)
- Besiedlung (1)
- Betten (1)
- Bioassay (1)
- Biocidal product regulation (1)
- Biokompatibilität (1)
- Biosorb (1)
- Blood supply (1)
- CAP , Plasma , Melanom , Sphäroid , Krebs <Medizin> (1)
- CHX (1)
- COVID-19 (1)
- Candida albicans (1)
- CarboFlex (1)
- Carcinogen (1)
- Central Sterile Supply Departement (1)
- Check-In (1)
- Check-Out (1)
- Checkliste (1)
- Chemotherapie (1)
- Chloraniline (1)
- Chlorhexidine (1)
- Chlorhexidine digluconate (1)
- Chlornitrobenzen (1)
- Chorioallantoismembran (1)
- Chronic renal failure (1)
- Community Medicine (1)
- Compliance (1)
- Compliance <Patient> (1)
- Comunity Medicine (1)
- Connexin (1)
- Contreet-H (1)
- Cx43 (1)
- Cystein (1)
- Cytokine secretion (1)
- DIN 12791 (1)
- DIN 14729 (1)
- DIN EN 12791 (1)
- DIN EN ISO 14729 (1)
- Dauer (1)
- Dekontamination (1)
- Dekubitus (1)
- Demographic change (1)
- Dialyse (1)
- Dielectric barrier discharge (1)
- Drei-Kammer-Verfahren (1)
- Durchfall (1)
- EN 1500 (1)
- ERIS (1)
- Effektivität (1)
- Efficacy (1)
- Effizienz (1)
- Einreibedauer (1)
- Einwirkzeit (1)
- Elektrochemische Oxidation (1)
- Elektrostimulation (1)
- Empfindlichkeit (1)
- Encasing (1)
- Endotoxin (1)
- Energy supply (1)
- Entscheidungsbaum (1)
- Epidemiologie (1)
- Epidermis (1)
- Erkältungskrankheit (1)
- Erregerzahl (1)
- Escherichia coli (1)
- Estradiol (1)
- EtG (1)
- Ethanol based hand rub (1)
- Ethylglucuronid (1)
- Etiology (1)
- Explantationstest (1)
- Exposition (1)
- Expositionsmessung (1)
- Extended-Spectrum Beta-Lactamase (1)
- Extrakorporale Dialyse (1)
- Eye antisepsis of slaughtered pigs (1)
- Factors for exacerbation (1)
- Fahreignungsbegutachtung (1)
- Fehlzeit (1)
- Fibroblast (1)
- Filtration (1)
- Flow-Cell (1)
- Flüssigkeit (1)
- Fragebogenerhebung (1)
- Frageborgen (1)
- Frauenmilch (1)
- Frequency in childhood (1)
- Früherkennung (1)
- Frühgeborenes (1)
- Fungi (1)
- Funktionseinheit (1)
- GABAA-Rezeptor (1)
- GIS (1)
- Galenics (1)
- Galenik (1)
- Gemeinschaftspraxis (1)
- Genital tract infection (1)
- Geographical (1)
- Gesundheitsstörung (1)
- Gesundheitsökonomie (1)
- Ghana (1)
- Glomerulonephritis (1)
- Glove (1)
- Gram-negative Bakterien (1)
- Gram-positive Bakterien (1)
- Granudacyn® (1)
- Grauer Star (1)
- Greifswald / Universität (1)
- Guanidinthiocyanat (1)
- HDBD (1)
- HET- CAM (1)
- HET-CAM (1)
- HET-MN (1)
- Hair follicle (1)
- Hand antisepsis (1)
- Handschweiß (1)
- Hausstaub (1)
- Hautbarriere (1)
- Hautdesinfektion (1)
- Hautflora prEN12791 handrubs chirurgisch (1)
- Hautmodell (1)
- Heil- und Hilfsmittel (1)
- Hepatitis B (1)
- Hexachlorophene (1)
- Hippocampus (1)
- Honig (1)
- Hormesis (1)
- Hornschicht (1)
- Human papilloma virus (1)
- Hygiene <Motiv> (1)
- Hygiene costs (1)
- Hygieneausgaben (1)
- Hygienekosten (1)
- Hygienemaßnahme (1)
- Hygieneordnung (1)
- Hygienestandard (1)
- Hygienic safety reusable tap water filters Germlyser® (1)
- Hygienische Händedesinfektion (1)
- Hypochlorous acid (1)
- Hühnerei (1)
- ISAAC (1)
- Immunstimulation (1)
- Implant surface (1)
- In vitro (1)
- In vivo laser scanning microscopy (1)
- Inactivation (1)
- Inaktivator (1)
- Inaktivierung (1)
- Indikatorhandschuhe (1)
- Indikatorsystem (1)
- Infektionen (1)
- Infektionskontrolle (1)
- Infektionsrate (1)
- Inflammation (1)
- Infusionssystem (1)
- Inhibitor (1)
- Intensivstation (1)
- Interaktion (1)
- Iodausscheidung (1)
- Iodresorption (1)
- Irritationsdermatitis (1)
- Katarakt (1)
- Keap1 (1)
- Kinder (1)
- Kompatibilität (1)
- Kontaktekzem (1)
- Kontaktlinse (1)
- Kontaktlinsenpflegemittel (1)
- Kontaktlinsenpflegesysteme (1)
- Kontamination (1)
- Kosten (1)
- Kostenanalyse (1)
- Kostensenkung (1)
- Krankentransport (1)
- Kurzinfusionen (1)
- Kurzinfusionssystem (1)
- Kühlwasser (1)
- LAL-Test (1)
- LVPC (1)
- Labyrinthversuch (1)
- Laminar air flow (LAF) (1)
- Langzeitwirkung (1)
- Latexhandschuhe (1)
- Lavasept (1)
- Lecithine (1)
- Leginella pneumophila (1)
- Lipofundin (1)
- Liposomen (1)
- Liposoms (1)
- Lumbalpunktion (1)
- MSSA (1)
- Maisstärke (1)
- Maisstärkepuder (1)
- Mantelgas (1)
- Massagemittel (1)
- Material (1)
- Matratzenbezüge (1)
- Maus (1)
- Maximalversorgung (1)
- Mecklenburg Vorpommern (1)
- Mecklenburg-Strelitz (1)
- Mecklenburg-Vorpommern / Rettungsdienstgesetz (1)
- Medihoney (1)
- Medizin (1)
- Medizinprodukt (1)
- Meerschweinchen (1)
- Melanom (1)
- Membranfilter (1)
- Memorandum (1)
- Menschliches Serum (1)
- Mikrobielle Raumluftbelastung (1)
- Mikroperforationen (1)
- Mikrowellen (1)
- Milben (1)
- Mitochondrium (1)
- Modell (1)
- Molecular dynamics simulation (1)
- Mucin (1)
- Mucositis (1)
- Mucous Membrane (1)
- Mundhöhle (1)
- Mundspülung (1)
- Mutagenität (1)
- Muttermilch (1)
- Nanopartikel (1)
- Nase (1)
- Neugeborenes (1)
- Neurotoxicity (1)
- Neutralisator (1)
- Neutralisierung (1)
- Neutralization (1)
- Nitrilhandschuhe (1)
- Non-enveloped viruses (1)
- Nosokomiale Infektion (1)
- Nosokomiale Infektionen (1)
- Nrf2 (1)
- Nutztiere (1)
- OCT (1)
- OP-Dauer (1)
- ORP (1)
- Octenidindihydrochlorid (1)
- Octenidine (1)
- Octenidine dihydrochlorid (1)
- Octenidol® md (1)
- Octenisept (1)
- Operation (1)
- Operationen (1)
- Oralchirurgie (1)
- Oxidativer Stress (1)
- Oxygen supply (1)
- PEF (1)
- PHMB adsorption (1)
- PTS (1)
- PVP-Iod (1)
- PVP-iodine (1)
- Parenterales Arzneimittel (1)
- Partikelzahl (1)
- Pasteurisierung (1)
- Pathogener Mikroorganismus (1)
- Patient safety (1)
- Penetration (1)
- Perforation (1)
- Perforation <Medizin> (1)
- Perforationsrate (1)
- Peripheral venous catheters (1)
- Peritoneallavage (1)
- Personalschutz (1)
- Pharmazeutische Technologie (1)
- Phosphatidylcholine (1)
- Physiotherapie (1)
- Plasma treatment in vivo (1)
- Plasmaeffekt (1)
- Pneumatic Tube System (1)
- Pneumatisches Tube System (1)
- Poly (hexamethylene biguanide) hydrochloride (PHMB) (1)
- Poly(hexamethylene)biguanide (1)
- Polyhexamethylenbiguanid (1)
- Polyhexamethylene biguanide (1)
- Polyhexanide (1)
- Postoperative Wundinfektionen (1)
- Povidone-iodine (1)
- Prion (1)
- Produktivitätsverlust (1)
- Prognose (1)
- Prognosis (1)
- Prontosan (1)
- Propan-2-ol (1)
- Propanole (1)
- Prophylaxe (1)
- Propionibakterien (1)
- Prüfanschmutzung (1)
- Puder (1)
- Qualitätsmanagement (1)
- RKI-Richtlinie (1)
- RNA (1)
- Ratten (1)
- Raumklima (1)
- Reconstructed human epidermis (1)
- Red blood cell concentrates (1)
- Redox signaling (1)
- Redoxpotential (1)
- Reizwirkung (1)
- Residual antimicrobial effect (1)
- Resistenz (1)
- Rettungsdienst (1)
- Ringer-Wundspüllösung (1)
- Ringer’s solution (1)
- Risikoanalyse (1)
- Risk–benefit-assessment (1)
- Rose Bengal staining (1)
- S. sanguinis Biofilm (1)
- SARS-CoV-2 (1)
- SKH1 mouse model (1)
- SR101 (1)
- SaOs‐2 cell differentiation (1)
- Schadstoffbelastung (1)
- Schilddrüse (1)
- Schimmelpilze (1)
- Schimmelpilzschaden (1)
- Schlachtschwein (1)
- Schleimhaut (1)
- Schule (1)
- Schulung (1)
- Screening (1)
- Sedimentation (1)
- Seife (1)
- Sekundärleistung (1)
- Sepsis (1)
- Sieben <Verfahrenstechnik> (1)
- Silver wound dressing (1)
- Sodium hypochlorite (1)
- Sporozide Händedesinfektion (1)
- Spülen (1)
- Sterilität <Hygiene> (1)
- Streptococcus mutans (1)
- Streptococcus sanguinis (1)
- Streptococcus sanguis (1)
- Suction blister (1)
- Suction blister technique (1)
- Surface barrier discharge plasma source (1)
- TEER (1)
- THP-1 macrophages (1)
- Tempus 600 (1)
- Therapy (1)
- Thiolgruppe (1)
- Ti6Al4V (1)
- Ti6Al4V alloy (1)
- TiO2 (1)
- Tissue tolerable plasma (1)
- Tissue-tolerable plasma (1)
- Training (1)
- Transepidermal water loss (1)
- Trinkwasser (1)
- Trinkwasserverordnung (1)
- UVA-LED (1)
- UVA-responsive (1)
- Ultraschall (1)
- Ultraschallkopf (1)
- Ultraschallsonde (1)
- Umweltanalyse (1)
- Umweltbericht (1)
- Umwelterklärung (1)
- Unterschenkelgeschwür (1)
- Untersuchungshandschuhe (1)
- Unterziehhandschuhe (1)
- VUV radiation (1)
- Validierung (1)
- Verwaltung (1)
- Virusinfektion (1)
- Vorpommern (1)
- WHO (1)
- WSP (1)
- Waschung (1)
- Wasseraufbereitung (1)
- Wasserdesinfektion (1)
- Wassergüte (1)
- Wasserhygiene (1)
- Wasserleitung (1)
- Wasserlinse (1)
- Wassersicherheitsplan (1)
- Wasserstoffionenkonzentration (1)
- Wasserstoffperoxid (1)
- Water Safety Plan (1)
- Water-filtered infrared-A radiation (1)
- Wirksamkeit (1)
- Wirksamkeitstestung (1)
- Wirtschaftlichkeit (1)
- Wirtschaftlichkeitsprinzip (1)
- Wirtschaftlichkeitsprüfung (1)
- Worker safety (1)
- Wound antiseptics, HET-CAM, irritation score, octenidine, chlorhexidine, polihexanide, hypochlorite, hydrogen peroxide, hemoglobin spray, allantoin, dexpanthenol, thiocyanate. (1)
- Wound at risk of infection (1)
- Wound at risk score (W.A.R. score) (1)
- Wound colonization (1)
- Wound healing (1)
- Wound management (1)
- Wound secretion (1)
- Wundantiseptik (1)
- Wundauflage (1)
- Wunde <Motiv> (1)
- Wundmodelle (1)
- Wundreinigung (1)
- Wundspülung (1)
- Wundversorgung (1)
- Wurzelkanalinstrument (1)
- ZSVA (1)
- Zahnbelag (1)
- Zahnklinik (1)
- Zellkommunikation (1)
- Zellmigration (1)
- Zellskelett (1)
- Zentrale Venenkatheter (1)
- Zinkoxid (1)
- Zoonose (1)
- Zwischenspülungen (1)
- absorption (1)
- activated carbon (1)
- alkoholische Händedesinfektionsmittel (1)
- allergic (1)
- ambulance car/rescue service (1)
- ambulance service (1)
- ambulanter Sektor (1)
- amino fluoride (1)
- anaesthesia (1)
- antimicrobial (1)
- antimicrobial activity (1)
- antimicrobial coating (1)
- antimicrobial efficacy (1)
- antimikrobiell (1)
- antimikrobielle Substanzen (1)
- application time (1)
- aseptisch (1)
- asthma (1)
- atmospheric pressure (1)
- bacteria (1)
- bakterielle Translokation (1)
- bed processing (1)
- carbon contamination (1)
- carcinogenic (1)
- cataract (1)
- cfu (1)
- checklist (1)
- chlorine (1)
- chloroaniline (1)
- chronische Krankheit (1)
- chronische Wunde (1)
- cold atmospheric plasma (1)
- cold atmospheric pressure plasma (1)
- cold atmospheric pressure plasma (CAP) (1)
- comparison (1)
- confocal laser scanning microscopy (1)
- contact killing surface (1)
- cooling water (1)
- cost analysis (1)
- cytotoxicity (1)
- decontamination (1)
- dental clinic (1)
- dermal (1)
- dermal exposition (1)
- dermal full-thickness wounds (1)
- dermatologic effect (1)
- dermatologischer Nutzen (1)
- desinfections and antiseptics (1)
- dezentrale Aufbereitung (1)
- diabetic foot (1)
- dialysis (1)
- disc carrier test (1)
- double gloving (1)
- dressing; silver; antibacterial activity (1)
- drinking-water (1)
- duwl (1)
- dynamic light scattering (1)
- education (1)
- effectiness (1)
- endotoxin binding (1)
- ethanol resorption (1)
- examination gloves (1)
- exposure (1)
- exposure time (1)
- filtration (1)
- fluoride gels (1)
- gefässkatheterassozzierte Infektionen (1)
- gewebeverträgliches Plasma (1)
- hair follicles (1)
- hairiness (1)
- hand desinfection (1)
- hand disinfection (1)
- hand hygiene (1)
- hand hygiene; hand rub; hand disinfection; skin care; interaction; EN 1500 (1)
- hand-hygiene (1)
- health and safety protection at the workplace (1)
- health economics (1)
- hepatitis b (1)
- hospital of maximum care (1)
- house dust (1)
- hydrogen peroxide (1)
- hydroxyethyl starch (1)
- hygiene reglement (1)
- hygienic hand desinfecrion (1)
- hygienic hand rub (1)
- hygienische Händedesinfektion (1)
- hypochlorous acid (1)
- immune response stimulation (1)
- implant coating (1)
- indoor air (1)
- inductively-limited discharge (1)
- infected wounds (1)
- infection control (1)
- infection prophylaxis (1)
- infection rate (1)
- infectious virus (1)
- inflammation (1)
- interaction (1)
- iodine (1)
- ion chromatography (1)
- irritation potential (1)
- isopropyl alcoholic absorption (1)
- isotonische Kochsalzlösung (1)
- kINPen (1)
- kINPen 09 (1)
- kINPen MED (1)
- kINPen plasma jet (1)
- kINPen09 (1)
- kINPenMed (1)
- kINpen (1)
- kaltes Atmosphärendruck-Argon-Plasma (1)
- kaltes Atmosphärendruckplasma (1)
- kaltes nicht thermisches Plasma (1)
- keine Angaben (1)
- kinpen09 (1)
- kontaminiertes Wasserreservoir (1)
- latex gloves (1)
- lenscare (1)
- liquids (1)
- low temperature plasma (1)
- macaques (1)
- medical devices (1)
- micelle (1)
- microbiology (1)
- microperforations (1)
- microwave (1)
- mikrobiologische Wasseranalyse (1)
- moDCs (1)
- mould damage (1)
- moulds (1)
- mouth rinse (1)
- mouthwash (1)
- mucosa model (1)
- mucositis (1)
- multi-resistant pathogens (1)
- multidrug-resistant microorganisms (1)
- nanocapsules (1)
- nitrate (1)
- nitrile gloves (1)
- nitrite (1)
- non-thermal plasma (1)
- nosokomial (1)
- nosokomiale Infektion (1)
- nosokomiale Infektionen (1)
- o/w-Emulsion (1)
- o/w-Emulsions (1)
- observance of hygiene (1)
- octenidindihydrochloride (1)
- octenidine dihydrochloride (1)
- osseointegration (1)
- outpatient setting (1)
- particle number (1)
- patiententransport (1)
- perforation rate (1)
- peripherer venöser Gefäßkatheter (1)
- peroxynitrite (1)
- physikalische Therapie (1)
- physiological saline solution (1)
- plaque (1)
- plasma discharge (1)
- plasma-treated water (1)
- polihexanide (1)
- polyhexamethylene biguanide (1)
- porcine skin model (1)
- postoperative Infektion (1)
- postoperative Wundinfektionen (1)
- postoperative wound infections (1)
- prevention (1)
- pulmonal (1)
- pulsed electric current (1)
- quantitative suspensiontest (1)
- quantitativer Suspensionstest (1)
- questionary survey (1)
- questionnaire (1)
- reactive oxygen species (1)
- reactive species (1)
- redox biology (1)
- redox signaling (1)
- reprocessing (1)
- rescue service (1)
- responsibility (1)
- rettungsdienst (1)
- rhino virus (1)
- rhinoconjunctivitis (1)
- risk assessment (1)
- risk evaluation (1)
- routine floor disinfection (1)
- routinemäßige Fussbodendesinfektion (1)
- sealant (1)
- secondary achievements (1)
- septisch (1)
- settled dust (1)
- sieving (1)
- silver wound dressing (1)
- skin (1)
- skin antisepsis (1)
- skin-compatibility (1)
- skincare (1)
- skinprotection (1)
- soap (1)
- sodium monofluorophosphate (1)
- soft lenses (1)
- source of transmission (1)
- surface (1)
- surface modification (1)
- surgical hand preparation (1)
- synaptic spines (1)
- synaptische Dornen (1)
- tap water (1)
- tape stripping model (1)
- three-chamber model (1)
- thyroid (1)
- titanium alloys (1)
- toothpaste (1)
- total bacterial count (1)
- transdermaler Ultraschall (1)
- treatment control (1)
- turbulente Verdünnungsströmung (1)
- turbulenzarme Verdrängungsströmung (1)
- ultrasonic probe (1)
- undergloves (1)
- vaccine (1)
- viral load (1)
- water contact angle (1)
- water safety plan (1)
- waterborne infections (1)
- wettability (1)
- wetting (1)
- wiederaufbereitbare Wasserfilter steril Trinkwasser Trinkwasserpathogenen (1)
- wound antisepsis (1)
- wound healing (1)
- wound irrigation (1)
- wound rinsing (1)
- wound test-model (1)
- Übertragungswahrscheinlichkeit MRSA (1)
- Übung (1)
Institute
- Institut für Hygiene und Umweltmedizin (151) (remove)
Publisher
- MDPI (14)
- S. Karger AG (10)
- BioMed Central (BMC) (3)
- Frontiers Media S.A. (1)
- IOP Publishing (1)
- John Wiley & Sons, Inc. (1)
Oral mucositis is the most common and severe non-hematological complication associated with cancer radiotherapy, chemotherapy, or their combination. Treatment of oral mucositis focuses on pain management and the use of natural anti-inflammatory, sometimes weakly antiseptic mouth rinses in combination with optimal oral cavity hygiene. To prevent negative effects of rinsing, accurate testing of oral care products is necessary. Due to their ability to mimic realistic in-vivo conditions, 3D models may be an appropriate option in compatibility testing of anti-inflammatory and antiseptically effective mouth rinses. We present a 3D model of oral mucosa based on the cell line TR-146 with a physical barrier, characterized by high transepithelial electrical resistance (TEER) and confirmed cell integrity. Histological characterization of the 3D mucosa model showed a stratified, non-keratinized multilayer of epithelial cells similar to that of human oral mucosa. By means of immuno-staining, tissue-specific expression of cytokeratin 13 and 14 was shown. Incubation of the 3D mucosa model with the rinses had no effects on cell viability, but TEER decreased 24h after incubation in all solutions except ProntOral®. Analogous to skin models, the established 3D model meets the quality control criteria of OECD guidelines and may therefore be suitable for comparing the cytocompatibility of oral rinses.
Aim
Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed.
Methods
THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted.
Results
No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden.
Conclusion
Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.
Unlike the native surface of the implant material (Ti6Al4V), oxidation with H2O2 leads to increased binding of the effective antimicrobial agent poly(hexamethylene) biguanide [PHMB]. However, treating with NaOH instead results in an even higher PHMB mass coverage. After oxidation with H2O2, strong differences in the PHMB adsorption capability between polished and corundum-blasted surfaces appear, indicating a roughness dependence. After NaOH treatment, no such effect was observed. The wetting properties of specimens treated with either H2O2 or NaOH prior to PHMB exposure clearly varied. To unravel the nature of this interaction, widespread in silico and in vitro experiments were performed. Methods: By X-ray photoelectron spectroscopy, scanning electron microscopy, water contact angle measurements and MD simulations, we characterized the interplay between the polycationic antimicrobial agent and the implant surface. A theoretical model for PHMB micelles is tested for its wetting properties and compared to carbon contaminated TiO2. In addition, quantitation of anionic functional group equivalents, the binding properties of PHMB with blocked amino end-group, and the ability to bind chlorhexidine digluconate (CHG) were investigated. Ultimately, the capability of osteoblasts to build calcium apatite, and the activity of alkaline phosphatase on PHMB coated specimens, were determined. Results: Simulated water contact angles on carbon contaminated TiO2 surfaces and PHMB micelle models reveal little influence of PHMB on the wetting properties and point out the major influence of remaining and recovering contamination from ambient air. Testing PHMB adsorption beyond the critical micelle concentration and subsequent staining reveals an island-like pattern with H2O2 as compared to an evenly modified surface with NaOH. Both CHG and PHMB, with blocked amino end groups, were adsorbed on the treated surfaces, thus negating the significant influence of PHMB’s terminal groups. The ability of osteoblasts to produce calcium apatite and alkaline phosphatase is not negatively impaired for PHMB mass coverages up to 8 μg/specimen. Conclusion: Differences in PHMB adsorption are triggered by the number of anionic groups and carbon contaminants, both of which depend on the specimen pre-treatment. With more PHMB covering, the implant surface is protected against the capture of new contamination from the ambient air, thus building a robust antimicrobial and biocompatible surface coating.
Objectives
Oral mucositis caused by intensive cancer chemotherapy or radiotherapy frequently results in pronounced damage of the oral mucosa leading to painful oral hygiene. To support oral care, antimicrobial effective mouth rinses may be used. Thus, the efficacy of a hypochlorite-based mouth rinse (Granudacyn®), assumed to be highly biocompatible because of the compounds being part of the natural pathogen defense, as possible antiseptic agent in case of oral mucositis was compared to that of an octenidine based antiseptic mouth rinse (Octenidol® md).
Materials and methods
The study was conducted as monocentric, controlled, randomized, blind cross over comparative study on 20 volunteers. As a proof of principle, we performed the study on orally healthy subjects and not cancer patients. The efficacy was determined as reduction of colony forming units (cfu) on buccal mucosa as well as in saliva. After mouth rinsing for 30 s, samples were taken after 1 min, 15 min, 30 and 60 min. The lg-reduction was calculated as difference between lg-values of cfu pre- and post-treatment.
Results
Both antiseptic mouth rinses induced a significant reduction of cfu on buccal mucosa and in saliva 1 min after mouth rinsing. The effect persisted up to 60 min. The octenidine based rinse was significantly superior to the hypochlorite-based rinse up to the last sample 60 min after rinsing. However, the known cytotoxicity of octenidine argues against its application.
Conclusion
Within the limits of this study, due to its antiseptic efficacy, the hypochlorite-based rinse Granudacyn® can be regarded appropriate to support the oral hygiene in patients with a sensitive oral mucosa during an aggressive cancer chemotherapy and radiation treatment in case of oral mucositis.
In einer offenen, kontrollierten, randomisierten, monozentrischen klinischen Studie an 241 Patienten mit geplanter Katarakt-OP wurde untersucht, ob es beim Einsatz von PVP-I-Lösung in der präoperativen Augenantiseptik zu einer Resorption von Iod kommt. Dazu wurden Konjunktiva und/oder periorbitale Haut mit 10 %igem bzw. 1,25 %igem PVP-Iod oder einem iodfreien Mittel behandelt und die Veränderung der Iodausscheidung bestimmt. Von der aufgetragenen verfügbaren Iodmenge wurden zwischen 0,24 und 1,77 % resorbiert. Es konnte gezeigt werden, dass es sowohl bei konjunktivaler als auch bei periorbitaler Applikation einer 10 %igen PVP-I-Lösung zu einer signifikanten Änderung der Iodausscheidung kommt. Bei Verwendung 1,25 %iger PVP-I-Lösung war keine signifikante Änderung der Iodausscheidung festzustellen, allerdings erhöhte sich die Anzahl der Patienten, deren Iodausscheidung im Bereich einer Iodkontamination (>300 µg/g Kreatinin) lag. Aufgrund dieser Ergebnisse ist der Einsatz einer 10 %igen PVP-I-Lösung auf der Konjunktiva abzulehnen. Bei Verwendung einer 1,25 %igen PVP-I-Lösung sind vor jeder präoperativen Augenantiseptik Schilddrüsenerkrankungen auszuschließen.
Problemstellung Nach dem Einzug in ein Verwaltungsgebäude traten nach ca. 8 Wochen in rekonstruierten Räumen sowie in Räumen der neugebauten Gebäudeteile Geruchsbelästigungen auf. Die Angestellten klagten über Befindlichkeitsstörungen, insbesondere über Schleimhautreizungen, Hautrötungen, Kopfschmerzen und Atembeschwerden. Auf Grund dieser Beschwerden wurden Raumluftmessungen veranlasst. Die Bewertung der Belastungen mit flüchtigen organischen Verbindungen (VOC's) in der Raumluft bereitet Schwierigkeiten, da es sich hier um eine Vielzahl chemisch zum Teil unterschiedlicher Verbindungen handelt und bis heute hinsichtlich der Belastung mit VOC's verschiedene Empfehlungen herausgegeben wurden, aber keine rechtsverbindlichen Grenzwerte existieren. Für die Beurteilung der Meßergebnisse wurde das Richtwertkonzept der ad-hoc-Arbeitsgruppe der Innenraumlufthygiene-Kommission des UBA (IRK) und der Arbeitsgemeinschaft oberer Landesgesundheitsbehörde (AOLG) zu Grunde gelegt. Methodik Zur Klärung der Frage, ob zwischen der Raumluftbelastung in den Arbeitsräumen des Verwaltungsgebäudes und den bei den Angestellten aufgetretenen Befindlichkeitsstörungen und gesundheitlichen Beschwerden ein Zusammenhang besteht, wurden standardisierte Befragungen mittels eines Fragebogens der Raumnutzer und im Vergleich mit einer Kontrollgruppe durchgeführt. Um die Inimissionssituation in den Arbeitsräumen beurteilen zu können, wurden qualitative und quantitative Messungen der Innenraumluft vorgenommen. Ergebnisse 2 Monate nach Bezug des Gebäudes wurden VOC-Gesamtkonzentrationen von 1700 nachgewiesen, nach 42 Monaten war die Belastung durch verschiedene Sanierungsmaßnahmen und intensives Lüften auf ca. 700 \i/m3 zurückgegangen. Bei der Betrachtung der Raumluftergebnisse konnte festgestellt werden, dass die Emission der Schadstoffe in dem Zeitraum von 3,5 Jahren nur langsam abnahm und sich das Schadstoffprofil (Aldehyderhöhung) zwischenzeitlich veränderte. Die Ergebnisse der umweltmedizinischen Befragungen korrellieren mit den Messergebnissen der umwelthygienischen Untersuchungen. Schlußfolgerungen Aufgrund der anhaltenden gesundheitlichen Beschwerden, die sich in Einzelbefunden und bei den Fragebogenaktionen zeigten, ist es erforderlich, durch geeignete Maßnahmen die Innenraumluft zu verbessern und den Gesundheitszustand der Betroffenen weiter zu kontrollieren. Insbesondere sind weiterführende Untersuchungen der Personen auf allergische Reaktionen und Entwicklung eines Belastungsasthmas notwendig. Für eine erfolgreiche Sanierung muss eine gezielte Materialauswahl und eine Bewertung deren Prüfzertifikate und - berichte erfolgen.
In der vorliegenden Untersuchung konnte bestätigt werden, dass die bisher aus dem Schrifttum bekannten Risikofaktoren für eine Kolonisation/Infektion von Patienten durch MRSA bei Krankenhausaufnahme nach wie vor zutreffen.
Ferner konnte in der vorliegenden Untersuchung nachgewiesen werden, dass die Verlegungshäufigkeit MRSA positiver Patienten von 2007-2010 abnahm. Damit nahm die Wahrscheinlichkeit einer nosokomialen Weiterverbreitung auf Patienten sowie der Übertragung von MRSA auf das Personal ab. In wie weit das und die vermutlich angestiegene Compliance bei der Einhaltung der SAA durch Hygieneschulungen und Supervision zur Abnahme einer MRSA- Kolonisation bei den Mitarbeitern führte, kann anhand der vorliegenden Daten nicht beantwortet werden.
Da die MRSA-Last im Jahr 2010 im Vergleich zum Jahr 2007 deutlich angestiegen ist, müssen die Präventionsmaßnahmen in ihrer Gesamtheit gegriffen haben. Zur Aufklärung der Bedeutung einzelner Präventionsmaßnahmen innerhalb der Multibarrieren-Strategie der MRSA- Prävention sind weitere Untersuchungen notwendig, um die Präventionsstrategie gegebenenfalls zu adjustieren.
In dieser Arbeit wird eine Methode entwickelt und angewendet, mittels welcher Wundauflagen hinsichtlich Endotoxin-Bindungskapazität, bakteriozider Wirkung, Endotoxin-Freisetzung und Zytotoxizität untereinander verglichen werden können. Hierzu werden die Wundauflagen in einer Endotoxin- bzw. Bakterien-Lösung inkubiert und nach festgelegten Kontaktzeiten der Endotoxin- bzw. der Bakteriengehalt im Überstand gemessen. Der Endotoxin-Nachweis erfolgt mittels LAL-Test, die Bakteriensuspensionen werden auf CSA-Platten kultiviert und ausgezählt. Die Untersuchung der Wundauflagen auf Zytotoxizität erfolgt in einem Agarose-Overlay In-vitro-Zytotoxizitätstest. Für Aquacel® ergibt sich die höchste Bindungskapazität für LPS. Der Aktivkohlekern der Wundauflage Actisorb® Silver hat ebenfalls eine hohe Endotoxin-Bindungskapazität. Die Aktivkohle-Auflage CarboFlex® bindet nur eine viel geringere Menge Endotoxins. Bei Contreet-H® kommt es zu einem Anstieg der Endotoxin-Konzentration nach Inkubation. Die silberhaltigen Wundauflagen Actisorb® Silver und Contreet-H® zeigen die beste bakteriozide Wirksamkeit. CarboFlex® und Aquacel® können die Bakterien in geringem Umfang binden, zeigen aber keine bakteriozide Wirksamkeit im eigentlichen Sinne. Unter Inkubation mit der Bakteriensuspension kommt es zu einer maximalen Endotoxin-Freisetzung von 100 EU/ml. Der Zytotoxizitätstest ergibt für Actisorb® Silver eine starke, für die übrigen Wundauflagen eine leichte Zytotoxizität.
Problemstellung Der Ausweis von Krankenhausleistungen in Bezug auf Sekundärleistungen ist suboptimal. Zur Sekundärleistung eines Krankenhauses zählt die technische Hygiene. Als eine in ihrer Lösung unterschiedlich diskutierte Aufgabenstellung der technischen Hygiene sollte in der vorliegenden Dissertationsschrift die Bettenaufbereitung unter ökonomischen Gesichtspunkten analysiert werden, da hierzu keine umfangreiche Kostenerhebung in der Literatur existiert. Fragestellung 1. Die Untersuchungen mussten die Anforderungen seitens des Gesetzgebers an die Hygieneleistungen im Krankenhaus berücksichtigen. Neben Aussagen zum Output, d.h. zum Nutzen des jeweiligen Verfahrens für die Patienten wird der Input über eine Kostenanalyse gemessen, um das Verfahren mit der besten Kosten-Nutzen-Relation zu identifizieren. 2. Daneben werden Optionen zur Kostenreduzierung auf Basis der Kostensenkungspotenziale der jeweiligen Verfahren verdeutlicht. 3. Zudem sollen im Zusammenhang mit der Bettenaufbereitung weiterführende Aspekte zur Kostenreduzierung aufgezeigt werden. Methode 1. Es wurden die drei in Deutschland angewendeten Verfahren zur Bettenaufbereitung, die dezentrale, die zentral-manuelle sowie die zentral-maschinelle Bettenaufbereitung, analysiert. 2. Zunächst erfolgte die Literaturrecherche, um anhand der gesetzlichen Auflagen das Soll zu ermitteln. 3. Die Ist-Erhebung stützt sich jeweils auf Betriebsstättenbesichtigungen bei Herstellern von Aufbereitungsanlagen, Begehungen in Krankenhäusern, Interviews mit Herstellern, Betreibern und Verantwortlichen von Bettenaufbereitungsanlagen in Bettenzentralen, Interviews mit Ausführenden und Verantwortlichen diverser Managementbereiche im Krankenhaus. 4. Für die Kostenanalyse wurden wesentliche Kostenarten untersucht. Die Kostenkalkulation basiert auf der fiktiven Beschreibung eines Maximalversorgers. Soweit möglich kamen Echtdaten zum Ansatz. 5. Die verwendeten Preise beziehen sich auf Listenpreise, ohne Rabatte und Skonti zu berücksichtigen. 6. Das recherchierte Datenmaterial wurde in Bezug auf Output und Input vergleichend gegenübergestellt und bewertet. Ergebnisse und Diskussion 1. Hygienisch-medizinischen Expertisen kann entnommen werden, dass jede Aufbereitungsform zum notwendigen Aufbereitungsergebnis führt, wofür die Motivation der Ausführenden eine Grundvoraussetzung darstellt. 2. Die Bettenaufbereitung erfolgt in Deutschland vornehmlich durch die Berufsgruppen Reinigungs-, Hol- und Bring- sowie Pflegedienst. 3. Die wesentlichen Kostenarten sind Bau-, Investitions-, Wartungs- und Instandhaltungs-, Material-, Betriebsmittel-, Personalkosten sowie Kosten durch Bettentransporte, wobei jede Aufbereitungsform unterschiedliche Kostenarten verursacht. 4. Bei den drei untersuchten Verfahren machen die Personalkosten jeweils den größten Anteil an den Gesamtkosten der Aufbereitungsprozesse aus (bis zu 89%). 5. Hinsichtlich der Aufbereitung der Betten in einer Bettenzentrale sind die für den Hin- und Rücktransport der Betten verbrauchten Personalressourcen respektive -kosten maßgeblich. 6. In Bezug auf die zentral-maschinelle Aufbereitung müssen die Kosten für Betriebsmittel neben den Personalkosten als bestimmend für die Gesamtkosten angesehen werden (bis zu 42%). 7. Hinsichtlich der Kostensenkung bieten die Personal- und Betriebsmittelkosten die größten Potenziale. 8. Die Personalkosten können durch die Wahl der für die Tätigkeit verantwortlichen Berufsgruppe reduziert werden. 9. Bei identischen Aufbereitungsergebnissen betragen die Kosten für die zentral-manuelle bzw. -maschinelle Aufbereitung im Vergleich zur dezentralen Bettenaufbereitung das rund 2,9 bzw. 4,5fache. Schlussfolgerungen 1. Die Kosten für die Bettenaufbereitung fallen für jeden Krankenhausfall an. Damit sind sie nicht vernachlässigbar. 2. Sekundärleistungen auf dem Gebiet der technischen Hygiene liefern für den Prozess der Bettenaufbereitung im Krankenhaus große Kostensenkungspotenziale. 3. Personalkosten stellen unabhängig vom Aufbereitungsverfahren den prozentual größten Anteil an den Gesamtkosten des Aufbereitungsprozesses dar. 4. Als unter ökonomischen und hygienisch-medizinischen Gesichtspunkten geeignetes Verfahren hat sich die dezentrale Bettenaufbereitung gezeigt.
Trinkwasser ist das wichtigste Lebensmittel und weltweit unersetzlich. Doch auch in der heutigen Zeit rangieren trinkwasserbedingte Infektionen mit hoher Bedeutung am internationalen Infektionsgeschehen (eine Milliarde Erkrankungen und drei Millionen Todesfälle pro Jahr). In Mitteleuropa spielen im Krankenhausbereich vor allem mikrobiologische Kontaminanten (vor allem Legionella spp. und Pseudomonas aeruginosa) eine bedeutende Rolle. Diese werden vor allem durch bautechnische (fehlerhafte Verteilungssysteme) und betriebstechnische (z.B. ungenügende Warmwasserbereitung) Missstände forciert. Die WHO (World Health Organization) empfiehl deshalb für Krankenhäuser und Gesundheitszentren die Etablierung eines WSP (Water Safety Plan) auf Basis des HACCP-Konzepts (Hazard Analyses Critical Control Points). Dieser soll die Trinkwasserqualität nicht nur durch mikrobiologische Untersuchungen gewährleisten. Bereits die Wasseraufbereitung, -Verteilung und -nutzung wird kritisch beurteilt, um Gefahren für die mikrobiologische und chemische Qualität weitestgehend zu eliminieren. Die vorliegende Arbeit erarbeitet wichtige Pathogene, die im Zusammenhang mit trinkwasserbedingten Infektionen stehen, und gibt Möglichkeiten der Kontamination und der Desinfektion von Trinkwasser. Darauf aufbauend wird ein WSP am Beispiel des Universitätsklinikums Greifswald formuliert.Trinkwasser ist das wichtigste Lebensmittel und weltweit unersetzlich. Doch auch in der heutigen Zeit rangieren trinkwasserbedingte Infektionen mit hoher Bedeutung am internationalen Infektionsgeschehen (eine Milliarde Erkrankungen und drei Millionen Todesfälle pro Jahr). In Mitteleuropa spielen im Krankenhausbereich vor allem mikrobiologische Kontaminanten (vor allem Legionella spp. und Pseudomonas aeruginosa) eine bedeutende Rolle. Diese werden vor allem durch bautechnische (fehlerhafte Verteilungssysteme) und betriebstechnische (z.B. ungenügende Warmwasserbereitung) Missstände forciert. Die WHO (World Health Organization) empfiehl deshalb für Krankenhäuser und Gesundheitszentren die Etablierung eines WSP (Water Safety Plan) auf Basis des HACCP-Konzepts (Hazard Analyses Critical Control Points). Dieser soll die Trinkwasserqualität nicht nur durch mikrobiologische Untersuchungen gewährleisten. Bereits die Wasseraufbereitung, -Verteilung und -nutzung wird kritisch beurteilt, um Gefahren für die mikrobiologische und chemische Qualität weitestgehend zu eliminieren. Die vorliegende Arbeit erarbeitet wichtige Pathogene, die im Zusammenhang mit trinkwasserbedingten Infektionen stehen, und gibt Möglichkeiten der Kontamination und der Desinfektion von Trinkwasser. Darauf aufbauend wird ein WSP am Beispiel des Universitätsklinikums Greifswald formuliert.
Zielsetzung: In den letzten Jahren wurden die Kontaktlinsenpflegemittelhersteller mit Daten, die eine erhöhte Komplikationsrate bei Kontaktlinsenträgern nach Gebrauch ihrer Produkte zeigten, konfrontiert, was zu weltweiten Rückrufaktionen führte und das Interesse der Medien weckte [1,3-5,200]. Daher erfolgte die erneute Prüfung von sechs auf dem Markt etablierten Kontaktlinsenpflegemitteln und einer Susbstanz in der Entwicklungsphase gemäß DIN EN ISO 14729. Methode: Die Kontaktlinsenpflegemittel wurden mit Hilfe des quantitativen Suspensionstests gemäß den Anforderungen der DIN EN ISO 14729 geprüft. Insgesamt wurden jeweils drei Wiederholungen durchgeführt. Bei Schwankungen der Ergebnisse > ± 0,5 Logstufen wurde das Kontaktlinsenpflegemittel in drei weiteren Versuchen geprüft. Zusätzlich erfolgte die Testung mit einer realitätsnahen, tränenflüssigkeitsähnlichen Belastung in Form von menschlichem Blutserum mit Zusatz von Lysozym und Muzin. Ergebnisse: Die Bewertung erfolgte nach den Anforderungen der DIN EN ISO 14729 und nach den verschärften Kriterien von Pitten et al. [157]. Insgesamt konnten nur eines der etablierten sechs Kontaktlinsenpflegemittel sowie das in der Entwicklungsphase befindliche Produkt die Anforderungen erfüllen. Bei den vier getesteten Peroxidsystemen zeigte sich bei dreien eine Wirkungslücke gegenüber S. aureus bei sonst guter mikrobiozider Wirkung. Die zwei geprüften All-in-One Systeme konnten nur vereinzelt zufriedenstellende antimikrobielle Resultate liefern. Beim Vergleich der Ergebnisse der Wiederholungsversuche zeigten sich v.a. bei den All-in-One Systemen unklare Schwankungen der Reduktionsfaktoren. Die Versuche mit menschlichem Serum führten zu keiner einheitlichen Wirkungsveränderung im Sinne einer Verbesserung oder Verschlechterung. Fazit: Insgesamt kann man dem Verbraucher nur eines der sechs etablierten Pflegemittel empfehlen. Die Peroxidsysteme zeigten gegenüber den All-in-One Sytemen deutliche Überlegenheit in der mikrobioziden Wirksamkeit. Von den zwei getesten All-in-One Systemen muss man aufgrund der Ergebnisse ausdrücklich abraten, um den Verbraucher vor Komplikationen zu schützen. Bei dem Produkt in der Entwicklungsphase handelt es sich um ein vielversprechendes Präparat mit sehr kurzer Einwirkzeit, was sich in weiteren Untersuchungen behaupten muss.
AbstractPlasma medicine refers to the application of nonequilibrium plasmas at approximately body temperature, for therapeutic purposes. Nonequilibrium plasmas are weakly ionized gases which contain charged and neutral species and electric fields, and emit radiation, particularly in the visible and ultraviolet range. Medically-relevant cold atmospheric pressure plasma (CAP) sources and devices are usually dielectric barrier discharges and nonequilibrium atmospheric pressure plasma jets. Plasma diagnostic methods and modelling approaches are used to characterize the densities and fluxes of active plasma species and their interaction with surrounding matter. In addition to the direct application of plasma onto living tissue, the treatment of liquids like water or physiological saline by a CAP source is performed in order to study specific biological activities. A basic understanding of the interaction between plasma and liquids and bio-interfaces is essential to follow biological plasma effects. Charged species, metastable species, and other atomic and molecular reactive species first produced in the main plasma ignition are transported to the discharge afterglow to finally be exposed to the biological targets. Contact with these liquid-dominated bio-interfaces generates other secondary reactive oxygen and nitrogen species (ROS, RNS). Both ROS and RNS possess strong oxidative properties and can trigger redox-related signalling pathways in cells and tissue, leading to various impacts of therapeutic relevance. Dependent on the intensity of plasma exposure, redox balance in cells can be influenced in a way that oxidative eustress leads to stimulation of cellular processes or oxidative distress leads to cell death. Currently, clinical CAP application is realized mainly in wound healing. The use of plasma in cancer treatment (i.e. plasma oncology) is a currently emerging field of research. Future perspectives and challenges in plasma medicine are mainly directed towards the control and optimization of CAP devices, to broaden and establish its medical applications, and to open up new plasma-based therapies in medicine.
Zusammenfassung
Zielsetzung: Ziel der vorliegenden experimentellen Studie war es, die Kontamination von Kurzinfusionssystemen an Zentralen Venenkathetern prospektiv zu untersuchen.
Methode: Die Probensammlung der Kurzinfusionssysteme erfolgte auf Intensivtherapiestationen. Es wurden ausschließlich Infusionssysteme zur Gabe von Kurzinfusionen verwendet. Infusionssysteme zur alleinigen Volumengabe wie E153 wurden von der Studie ausgeschlossen.
Beim Wechsel des Kurzinfusionssystems nach einer 72-stündigen Verwendungsdauer wurde die im System verbliebene Restlösung für 48 h bei 36 °C auf Blutagar zum Nachweis einer Kontamination kultiviert.
Ergebnisse: In einer von 616 Proben wurden 10 KbE Coagulase-negative Staphylokokken (CoNS) pro ml nachgewiesen.
Eine Kontrolltestung war bei dieser Probe zu Beginn der Studie nicht vorgesehen, sodass das getestete Kurzinfusionssystem als kontaminiert galt.
2 weitere Proben in der Anschlussuntersuchung wiesen wiederum 10 KbE CoNS pro ml auf, was bei einer Kontrolltestung mittels erneuter Kultivierung der Infusionslösung nicht bestätigt wurde, sodass der initiale Befund als Laborkontamination gewertet wurde. Damit liegt auch bei der kontaminierten Probe eine Laborkontamination (z.B. Hautflora) nahe, ohne die Durchführung einer Kontrolltestung konnte dies jedoch nicht bewiesen werden.
Schlussfolgerung: Infusionssysteme werden bei intermittierender Gabe von Kurzinfusionen mit Zwischenspülungen und einer Verwendungsdauer von 72h mikrobiell nicht kontaminiert. Obwohl das nur für aerob wachsende Bakterien nachgewiesen wurde, ist die Art der Entstehung einer Kontamination beim Umgang mit ISs für Aerobier und Anaerobier analog, so dass bei fehlendem Nachweis von Aerobiern kein Risiko einer Kontamination mit Anaerobiern anzunehmen ist. Damit können ISs bei intermittierender Gabe von Kurzinfusionen mit Zwischenspülungen bis zu 72 h verwendet werden, wodurch können Kosten eingespart werden.
Die vorliegende Arbeit hat sich zum Ziel gesetzt, diejenige MRSA-Screening- und Managementstrategie zu identifizieren, die für ein bestimmtes Krankenhaussetting die geringsten erwarteten Kosten verursacht. Dazu wurde eine Entscheidungsbaumanalyse durchgeführt und zugehörige Kalkulationen angestellt. Darüber hinaus wurde im Rahmen einer Mehrweg-Sensitivitätsanalyse die Ergebnisstabilität überprüft und mit Hilfe von Einweg-Sensitivitätsanlaysen ermittelt, welche Parameter den größten Einfluss auf das Ergebnis bzw. die Ergebnisstabilität nehmen.
Die Anwendung von Niedrigtemperatur-Atmosphärendruckplasmen im Bereich der
Wundversorgung gewinnt stetig an Bedeutung und so steigt das Interesse an den damit
ausgelösten biologischen Vorgängen im Organismus. Es bestehen zahlreiche Studien zum
Einfluss von Plasma auf verschiedene Zellen in Kultur. In der vorliegenden Arbeit wurde die
Wirkung von Plasma auf einen intakten Zellverband, der menschlichen Haut, umfangreich
molekularbiologisch untersucht.
Es wurde der Atmosphärendruck-Plasmajet kINPen® MED verwendet, um ex-vivo
Hautproben von insgesamt 9 Patienten zu behandeln. Mittels Fluoreszenzmikroskopie wurden die Hautbiopsien hinsichtlich Differenzierung, Proliferation, Apoptose und DNA 24 Stunden nach Plasmaexposition beurteilt. Weiterhin wurde die Sekretion von Zytokinen mittels ELISA erforscht. Die Dauer der punktuellen Plasmabehandlungen betrug 1 Minute, 3 Minuten und 5 Minuten.
Die größten Limitationen im Studiendesign waren der geringe Probenumfang sowie die
Inhomogenität der Versuchsgruppen. Es konnten keine signifikanten Unterschiede zwischen
behandelter und unbehandelter Hautprobe nachgewiesen werden. Trotz allem wurden
wichtige Tendenzen beobachtet. Die Anwendung des Plasmas scheint das grundsätzliche
Differenzierungsmuster der Epidermis kaum zu beeinflussen. Bei längerer Behandlung bis 5
Minuten stieg die Anzahl basaler apoptotischer Zellen, während es kaum Änderungen im
Auftreten von DNA Doppelstrangbrüchen sowie der Sekretion von IL6 oder IL8 gab. Die
Anzahl proliferativer basaler Zellen stieg bis zu einer Plasmaexposition von 3 Minuten.
Möglicherweise wirken kurzzeitige Plasmabehandlungen proliferationsfördernd auf
Keratinozyten. Dies könnte eine weitere Erklärung für den positiven Einfluss von Plasma auf
die Heilung von Wunden sein. Längere Behandlungen lösen womöglich Apoptosen aus,
jedoch ohne DNA Schäden herbeizuführen.
Um Nebenwirkungen zu minimieren, bedeutet dies für die klinische Praxis, möglichst kurze
Expositionszeiten einzuhalten. Um eine optimale therapeutische Anwendung
unterschiedlicher Plasmaquellen, die sich in Zusammensetzung und Intensität unterscheiden,
zu ermöglichen, sind weitere Studien bezüglich Behandlungszeit und entsprechender
biologischer Wirkung notwendig.
Wichtige Ergebnisse dieser Arbeit sind in die Publikation von Hasse et al. eingeflossen
(Hasse et al. 2016).
Ein in Zahnarztpraxen präsentes Problem ist die mikrobielle Kontamination des Wassers durch Biofilmbildung in den wasserführenden Leitungen der ZE. Die Studie basiert auf dem Aspekt, dass die derzeitigen Dekontaminationsanlagen mit Zudosierung von Oxygenal keine sichere Wirkung in Bezug auf die Einhaltung der Trinkwasser Verordnung garantieren können. Deshalb wurde ein neues Verfahren auf der Basis von anodischer Oxidation unter Praxisbedingungen geprüft. Der Einfluss einer regelmäßigen permanenten Desinfektion mit zusätzlicher sog. Stoßdesinfektion wurde bei mehreren kontaminierten ZE (Behandlung 1, 2 und 3) und dem Auslass im Patienten-WC mit dem neuen Produkt POTOCLEAN® über 7 Monate geprüft. Regelmäßig wurden die mikrobielle Kontamination, Chlor- und Redoxwerte gemessen. An ZE 1 und 2 (ca. 13 Jahre alt) ergab sich Folgendes: Durch die mehrstündigen Stoßdesinfektionen (3 Termine) ließ sich die GKZ für eine kurze Zeitperiode (<7 d) senken; diese Wirkung persistierte lediglich bis zur folgenden Messung nach einer Woche. Daraufhin stiegen die Werte trotz permanenter Niedrigdosierung (1 mg/l) von POTOCLEAN® wieder an. Durch die starke Chlorzehrung bei vergleichsweise geringen zugeführten Chlormengen wurden niedrige Gesamtchlor-Werte bei den Routinemessungen erfasst. Das Redoxpotential zeigt ähnliche Tendenz, da auch der elektrochemische Wert durch die nur geringe Natriumhypochloritwirksamkeit niedrig gehalten wurde. Während bzw. kurz nach den Stoßdesinfektionen fand insgesamt ein Anstieg der Werte statt, der durch die höhere Menge POTOCLEAN® bedingt ist. Sobald sich aber die Mikroorganismen bei den folgenden geringen POTOCLEAN® Mengen regenerieren, sinken die Gesamtchlor- und Redoxwerte wieder, da die Chlorzehrung steigt. ZE 3 stellt durch ihren vorteilhaften Bau (Vermeidung von Wasserstagnation etc.) und die allgemein geringere (auch altersbedingte) mikrobielle Kontamination ein durch Desinfektionsmittel wesentlich einfacher zu behandelndes Objekt dar. Spätestens nach der ersten Stoßdesinfektion lagen alle mikrobiellen Werte nachhaltig bei 0. Wichtige Einflussfaktoren waren das Alter und die damit in Zusammenhang stehende Konstruktion von zwei der drei ZE (Behandlung 1 und 2) bzw. von dem Wasserhahn des Patienten-WC und die damit verbundene Biofilmausprägung zu Beginn des Projekts.
Auf der Intensivstation der Abteilung für Neonatologie der Klinik und Poliklinik für Kinder- und Jugendmedizin der Universität Greifswald wurde eine prospektive Studie auf Grund einer vermutlich erhöhten Rate neonatater Sepsisfälle durchgeführt. Von Juli bis Dezember 2000 wurden regelmäßig von der Umgebung der Frühgeborenen Abstriche genommen und mikrobiologisch untersucht. Gleichzeitig wurden die Krankenakten der Neonaten aufgearbeitet und relevante Daten wie Geburtsgewicht, Gestationsalter, intravenöse Zugänge, Atemhilfen, Antibiose, Art der Nahrung, Sepsisbeginn und CrP- Wert in ein Protokoll eingetragen. Zusammenhänge zwischen den aufgenommenen Parametern und Sepsishäufigkeit wurden mittels statistischer Berechnungen untersucht. Es stellte sich heraus, dass die Sepsishäufigkeit entscheidend von dem Gestationsalter abhängig ist. Neonaten, die vor der 30. Schwangerschaftswoche geboren wurden, hatten in 94,1 % der Fälle eine Sepsis. Frühgeborene, die nach der 32. SSW geboren wurden, hatten hingegen nur eine Rate von 17,4 %. Von den Kindern, die zwischen der 30. und 32. SSW geboren wurden, hatten 58,3 % eine Sepsis. Bei Neugeborenen mit einem Gestationsalter < 30. SSW ist das Immunsystem noch so stark unterentwickelt, dass bei ihnen schon physiologische Hautkeime eine Infektion auslösen können. Deshalb müssen Neugeborene unter der 30. SSW streng aseptisch gepflegt werden. Die häufigsten Erreger, die bei den Abstrichen isoliert wurden, waren KNS, Klebsiella spp. und Candida spp. Bei 82 % der Patienten wurden KNS, bei 75 % der Kinder Klebsiella spp, nachgewiesen. Candida spp. wurde bei 12 von 28 Patienten isoliert. Dies spricht für eine Verbreitung dieser Erreger auf der Intensivstation, die bei Unterlassung von Distanzierungs- und Desinfektionsmaßnahmen durch das Personal von Kind zu Kind übertragen werden können.
In Abhängigkeit von der Dauer, der Art und des mechanischen Anspruchs eines operativen Eingriffs kommt es nachweislich zu Perforationen von Operationshandschuhen und damit zu einer Aufhebung der aus infektionsprophylaktischen Gründen erforderlichen intakten Barriere zwischen Operateur bzw. medizinischem Personal und dem Patienten. Dabei spielen intakte Handschuhe nicht nur eine tragende Rolle hinsichtlich des beiderseitigen Schutzes vor durch Blut und andere Körperflüssigkeiten übertragenen Infektionskrankheiten wie HIV, HBV und HCV, sondern auch vor bakteriellen Übertragungen als einer potentiellen Ursache postoperativer Wundinfektionen. Die Perforationsrate von Handschuhen korreliert mit der Tragedauer, wobei eine Vielzahl der Handschuhperforationen nicht sofort oder überhaupt nicht bemerkt wird. Dabei sind Handschuhperforationen überproportional häufig an der nicht dominanten Hand lokalisiert. Im Gesamtergebnis der durchgeführten Untersuchung und einer Vorgänderstudie [1] konnte unter realen Operationsbedingungen eine Gesamtperforationsrate von 18,2 % nachgewiesen werden. Es fanden 12 Bakterientranslokationen, entsprechend einer Translokationsrate von 22,2 %, bezogen auf die Gesamtzahl perforierter Handschuhe, statt und zwar nach einer Tragezeit ab 90 min [1] bzw. in dieser Untersuchung bereits nach 62 min. Das Vorhandensein für bakterielle Erreger permeabler Handschuhperforationen ermöglicht ebenso eine Passage von Viren. Ein regelmäßiger intraoperativer Handschuhwechsel für den viszeralchirurgischen Operateur und/oder double gloving stellen aus den Untersuchungsergebnissen abgeleitete Möglichkeiten dar, die notwendige intakte Barriere aufrecht zu erhalten bzw. wiederherzustellen. Diesbezüglich ist eine Differenzierung zwischen unterschiedlichen chirurgischen Disziplinen und den jeweils unterschiedlichen Aufgaben innerhalb des Operationsteams vorzunehmen, da zwangsläufig erhebliche Unterschiede bei den Perforationsraten bestehen. Das in diesem Zusammenhang untersuchte und aus jeweils doppelt übereinander getragenen Operationshandschuhen bestehende Indikatorsystem erwies sich in der aktuellen Untersuchung als effektiv. Über den Untersuchungszeitraum von einem Jahr zeigte sich eine deutlich zunehmende Verbesserung in der visuellen Detektion von Perforationen durch die einzelnen Mitglieder des Operationsteams, wobei die Erkennungsrate bei 70 % lag. Die Empfehlung eines intraoperativen Handschuhwechsels nach spätestens 90 min für den ersten und zweiten viszeralchirurgischen Operateur sowie nach 150 min für die übrigen Teilnehmer der Operation kann durch die vorliegende Untersuchung untermauert werden. Der intraoperative Einsatz des Indikatorsystems ist aufgrund guter Erkennbarkeit von Perforationen in Verbindung mit erhöhter Sicherheit durch das systemeigene double gloving grundsätzlich zu empfehlen.
Die Händedesinfektion ist essentiell zur Verhinderung nosokomialer Infektionen. Hierbei zeigen sich alkoholische Desinfektionsmittel auf Basis von Ethanol und Propanolen als besonders effektiv. Bei ethanolhaltigen Desinfektionsmitteln konnte eine Resorption im toxisch relevanten Ausmaß ausgeschlossen werden. Bei der Anwendung von Propanolen fanden sich nach exzessiver Händedesinfektion erhöhte Serumspiegel, die eine Bewertung unter Praxisbedingungen notwendig machten, um eine gesundheitliche Gefährdung durch Anwendung im täglichen Gebrauch auszuschließen. In diesem Zusammenhang stellte sich die Frage, ob es bei praxisnaher chirurgischer Händedesinfektion mit okkludierter Haut eine relevante dermale Resorption der Propanole gibt und ob diese als gesundheitsgefährdend anzusehen ist. Auf Grund der Literaturrecherche zu Resorptionsvorgängen an der Haut war eine dermale Resorption wahrscheinlich. Die Anzahl von in-vitro Untersuchungen überwiegt jedoch. Nur wenige in-vivo Studien beschäftigen sich mit der Frage, ob und in welchem Ausmaß Propan-1-ol und Propan-2-ol im Rahmen der alkoholischen Händedesinfektion resorbiert werden. Mit Hilfe von 10 operativ tätigen Probanden wurden bei 3 verschiedenen propanolhaltigen Desinfektionsmitteln (Gehalt von 70 % [w/w] Propan1-ol, 63,14 % [w/w] Propan-2-ol, 30 % [w/w] Propan-1-ol und 45 % [w/w] Propan-2-ol) die dermale Resorption nach Applikation untersucht. Je Proband kam an drei verschiedenen Tagen jeweils eines der Desinfektionsmittel zum Einsatz. An jedem Versuchstag erfolgten eine hygienische und drei chirurgische Händedesinfektion mit dem jeweils zu testenden Präparat in vorgegebenen Zeiträumen. Zu verschiedenen Zeitpunkten wurden Blutproben genommen, um die Resorption und die Metabolisierung in Ausmaß und zeitlichem Verlauf darstellen zu können. Durch die Untersuchung der Blutproben fanden wir signifikante Erhöhungen der Propanol-Serumspiegel unabhängig vom verwendeten Präparat. Die maximale mediane Blutkonzentration wurde für Propan-1-ol bei 4,09 mg/l und für Propan-2-ol mit 2,56 mg/l bestimmt. Der maximale Serumspiegel von Propan-1-ol wurde mit 25,8 mg/l und bei Propan-2-ol unter der Verwendung des Propan-1-ol Monopräparats mit 5,4 mg/l ermittelt. Bei der Verwendung der Wirkstoffkombination traten maximale Serumspiegel von 9,7 mg/l für Propan-1-ol und 5,3 mg/l für Propan-2-ol auf. Für den 44 Metaboliten von Propan-1-ol, Aceton, fanden wir in allen Versuchen einen signifikanten Anstieg. Für Propionaldehyd, der Hauptmetabolit von Propan-2-ol, waren keine Erhöhungen messbar. Die gemessenen Werte zeigen eine Beziehung zwischen Applikation und Resorption der Propanole auf, die signifikant ist, aber im Vergleich zu toxikologisch relevanten Mengen gering erscheint. Unklar ist der Einfluss einer pulmonalen Resorption. Eine akute gesundheitliche Gefährdung durch eine Propanolresorption im Zusammenhang mit der chirurgischen Händedesinfektion ist bei gesundem Anwender und vorschriftsmäßiger Applikation unwahrscheinlich. Die langfristigen Auswirkungen sind durch die vorliegenden Daten nicht sicher abschätzbar. Bei weiteren Studien sollte die pulmonale Resorption berücksichtigt werden.
Gegenstand der hier vorgestellten Arbeit ist die Beschichtung von Wundauflagen mit Zinkoxid- und Silberhaltigen antibakteriellen Schichten. Die Aufbringung der Schichten erfolgt dabei auf den Wundauflagen mittels Atmosphärendruckplasma. Die Matrix der Schichten besteht aus Siliziumdioxid, in welcher die Wirkstoffe eingelagert sind. Auf diesem Weg hergestellten Wundauflagen wurden hinsichtlich ihrer antibakteriellen Wirkung und zytotoxischen Eigenschaften charakterisiert. Ziele waren ein minimaler Einsatz an Wirkstoffen und die Nutzung eines modernen Beschichtungsverfahrens. Der zytotoxische Einfluss der Wundauflagen wurde an 3D-Hautmodellen im Vergleich zu den am Markt befindlichen Produkten validiert.
Der Gesetzgeber verlangt aus Gründen der Arzneimittelsicherheit für nasal anwendbare Arzneimittel und Medizinprodukte (Nasalia) in Mehrdosisbehältnissen den Zusatz von geeigneten Konservierungsmitteln in angemessener Konzentration (Eu. Pharm. 2001). Diese dienen dem Schutz des Inhalts vor Keimen aus der Umgebung nach Anbruch (mikrobiologische Anbruchstabilität). Es gibt kein Konservierungsmittel, das alle Anforderungen erfüllt und universell für alle Formulierungen einsetzbar ist. Da Konservierungsmittel per Definition Keime abtöten bzw. ihre Vermehrung verhindern muss, ist zwangsläufig eine gewisse Zytotoxizität gegeben. Da die meisten Nasalia immer noch konserviert sind, lässt sich die Forderung des Arzneibuchs nach Zubereitungen zur nasalen Applikation, die nicht reizend sind und keine unerwünschten Wirkungen auf die Funktion der mukoziliaren Clearance ausüben, in diesem Fall nur bedingt erfüllen. Der Kompromiss zwischen Verträglichkeit und mikrobiologischer Sicherheit geht bei den konservierten Präparaten auf Kosten der Verträglichkeit. Dabei addieren sich die zytotoxischen Eigenschaften der arzneilich wirksamen Substanz mit der Zytotoxizität des Konservierungsmittels. Grundsätzlich ist daher der Einsatz von Konservierungsmitteln in der heutigen Zeit zu hinterfragen. Mit Hilfe dieser Substanzen werden nur die Folgen einer mikrobiologischen Kontamination bekämpft, anstatt die Ursachen auszuschließen. Moderne Pumpsysteme machen es möglich, konservierungsmittelfreie Nasensprays herzustellen und so den umstrittenen Zusatz des am häufigsten eingesetzten Konservierungsmittels Benzalkoniumchlorid zu vermeiden. Im Rahmen dieser Arbeit wurden folgende Ergebnisse erzielt: - In der größten und am häufigsten eingesetzten Gruppe der Vasokonstriktiva (Xylometazolin, Oxymetazolin, Tetryzolin, Tramazolin) wurde durch den Verzicht auf Benzalkoniumchlorid ein signifikanter Anstieg der Verträglichkeit registriert. Da diese Kombination von Wirkstoff und Konservierungsmittel besonders zellschädigend ist, ist es empfehlenswert auf konservierte Formulierungen zu verzichten. In der Gruppe der Antiallergika wurden mit Ausnahme von Cromo-ratiopharm analoge Ergebnisse erzielt. Die schlechte Verträglichkeit (Zellwachstum nur 1,1%) der unkonservierten Formulierung ist auf die Matrix (hypoton) zurückzuführen. In der Gruppe der Kortikosteroide sind alle Formulierungen konserviert und schlecht verträglich. Neue Entwicklungspräparate (ölige Matrix, unkonserviert, ohne Hilfsstoffe) sind dagegen gut verträglich. Hier bietet sich eine Möglichkeit, preiswerte und gut verträgliche Präparate herzustellen, vor allem für die Patientengruppen, die über Brennen, Trockenheit oder Irritationen nach Benutzung der herkömmlichen Nasalia klagen. In der Gruppe der Heil- und Pflegemittel mit arzneilichen Zusätzen sind alle un-konservierte Präparate gut verträglich. Der Verzicht auf Benzalkoniumchlorid erhöht die Verträglichkeit. Die getesteten Öle sind ebenfalls gut verträglich. In Bereich der Hormone scheint die Faustregel der besseren Verträglichkeit nach Verzicht auf Benzalkoniumchlorid nicht immer zu gelten. Die wachstumsfördernde Wirkung des Hormons Calcitonin scheint einen Einfluss auf die Ergebnisse der Zytotoxizitätstest zu haben. In der Gruppe saliner Lösungen sind alle Nasensprays konservierungsmittelfrei und gut verträglich. Der Zusatz von Dexpanthenol hat einen positiven Einfluss auf die Verträglichkeit. Der Zusatz von Aloe vera hat keinen keinen Einfluss auf die Verträglichkeit. Die Gruppe der Analgetika besteht vorwiegend aus Entwicklungspräparaten. Der Zusatz von Hyaluronsäure hat einen positiven Einfluss auf die Verträglichkeit, die bis auf Werte im Bereich saliner Lösungen liegen. Hier eröffnet sich eine zukünftige Möglichkeit, gut verträgliche Analgetika herzustellen. Die Reaktion des Gesetzgebers auf die in der Literatur reichlich beschriebenen Nebenwirkungen von Benzalkoniumchlorid lässt hoffen, dass vor allem die neu zugelassenen Nasensprays konservierungsmittelfrei und somit besser verträglich werden.
Background: Annual transfusion rates in many European countries range between 25 and 35 red blood cell concentrates (RBCs)/1,000 population.It is unclear why transfusion rates in Germany are considerably higher (approx. 50–55 RBCs/1,000 population). Methods: We assessed the characteristics of transfusion recipients at all hospitals of the German federal state Mecklenburg-Western Pomerania during a 10-year longitudinal study. Results: Although 75% of patients received ≤4 RBCs/patient in 2015 (1 RBC: 11.3%; 2 RBCs: 42.6%; 3 RBCs: 6.3%; 4 RBCs: 15.0%), the mean transfusion index was 4.6 RBCs due to a minority of patients with a high transfusion demand. Two thirds of all RBCs were transfused to only 25% of RBC recipients. Consistently, male patients received a higher number of RBCs (2005: 54.2%; 2015: 56.8%) and had a higher mean transfusion index than female patients (mean 5.1 ± 7.2; median 2; inter-quartile range [IQR] 2–4 vs. mean 4.0 ± 5.8; median 2; IQR 2–4). The absolute transfusion demand decreased between 2005 and 2015 by 13.5% due to a composite of active reduction (clinical practice change) and population decline in the 65- to 75-year age group (lower birth rate cohort 1940–1950); however, with major differences between hospitals (range from –61.0 to +41.4%). Conclusion: Transfusion demand in a population could largely be driven by patients with high transfusion demand. Different treatment practices in this group of patients probably add to the major differences in transfusion demand per 1,000 individuals between countries. The available data cannot prove this hypothesis. Implementation of a diagnosis-related group-based monitoring system is urgently needed to allow informative monitoring on the population level and meaningful comparisons between transfusion practices.
Im deutschen Gesundheitswesen stellt MRSA nicht nur im stationären, sondern auch im ambulanten Bereich eine Behandlungserschwernis dar. Patienten mit chronischen Wunden sind bei MRSA-Infektionen besonders gefährdet. Deshalb wurden als Ausgangslage für die vorliegende Arbeit die Forschungsfragen formuliert, ob a) eine ambulante MRSA-Sanierung bei Patienten mit chronischen Wunden durchführbar ist und b) die damit erzielbaren Fallerlöse die Praxiskosten decken. Zur Beantwortung der Frage wurden a) Berichtsdaten der Kassenärztlichen Bundesvereinigung an das Bundesministerium für Gesundheit b) Abrechnungsdaten der Kassenärztlichen Vereinigung Mecklenburg-Vorpommern und c) die Daten der MRSA-fokussierten MEracL-Studie (MRSA eradication for chronic lesions) analysiert. Auf Grund der Ergebnisse konnten fünf Kernaussagen formuliert werden: 1) Die Durchführung einer ambulanten Sanierungsbehandlung ist möglich. 2) Das Vorhandensein einer chronischen Wunde ist ein MRSA-Risikofaktor, aber kein Hemmnis für die Durchführung einer ambulanten Sanierungsbehandlung. 3) Die Akzeptanz der Ärzte hinsichtlich der Durchführung einer ambulanten Sanierungsbehandlung ist regional unterschiedlich. 4) Die errechneten Fallerlöse decken nicht die realen Praxiskosten. 5) Das Budget für Leistungen im Zusammenhang mit MRSA sollte sektorenübergreifend geplant und eingesetzt werden. Die vorliegende Arbeit unterstreicht die Wichtigkeit einer gesundheitsökonomischen Analyse bei der Einführung neuer Behandlungsmethoden.
Ziel der Studie war die Beantwortung der Fragestellung, ob es im Klinikum Pasewalk aus krankenhaushygienischer Sicht Einwände gegen einen Wechsel der orthopädischen Operationen von einer mit TAV ausgestatteten OP-Einheit in eine mit TVS belüftete OP-Einheit gibt. Zusätzlich sollten Einflussfaktoren auf die partikuläre und mikrobielle Belastung der Raumluft einschließlich der Rolle der RLT-A analysiert werden. Besonderes Interesse galt hierbei dem Messpunkt direkt am OP-Gebiet.
Als Qualitätsparameter der Raumluft wurden bei insgesamt 48 Operationen die Partikelkonzentration an drei Messpunkten und die mikrobielle Belastung der Raumluft an vier Messpunkten während des regulären OP-Betriebs in zwei OP-Einheiten gemessen. Zur Beurteilung der Partikelkonzentration der Raumluft an den 3 Messpunkten wurden Partikel der Größen 0,5 – 4,9µm und >5 µm kumulativ gemessen. Für die Erfassung der mikrobiellen Belastung der Raumluft wurden Sedimentationsplatten an 4 Messpunkten eingesetzt.
Die mikrobielle Belastung war an den Messpunkten am OP-Gebiet, am Instrumententisch und in der Nähe der aseptischen Arbeitsflächen im OP 1 mit TAV signifikant geringer als im OP 2 mit TVS. Zusätzlich wiesen alle Messpunkte eine signifikant geringere partikuläre Belastung (sowohl unterhalb als auch außerhalb der TAV) im OP 1 mit TAV auf.
Es konnte gezeigt werden, dass die Anzahl der im Hintergrund tätigen Personen die Partikelkonzentration (>5,0 µm) und die mikrobielle Belastung am OP-Gebiet erhöht. Diese Effekte sind nur in OP 2 mit TVS nachweisbar. Zudem konnte ein positiver Zusammenhang zwischen Partikelkonzentration (>5,0 µm) und mikrobieller Belastung festgestellt werden.
Als Fazit kann eine Empfehlung zum Wechsel der OP-Einheiten nicht ausgesprochen werden. Zudem konnte gezeigt werden, dass eine RLT-A mit TAV einen verringernden Einfluss auf die Erregerbelastung und Partikelbelastung am OP-Gebiet haben kann. Sie ist zudem über ihren Schutzbereich in der Lage Auswirkungen von Umgebungseinflüssen auf mikrobielle und partikuläre Belastung am OP-Gebiet signifikant zu verringern.
Durch die chirurgische Händedesinfektion soll eine möglichst effektive Verminderung der Koloniezahlen der Hände des chirurgischen Personals vor Durchführung eines operativen Eingriffs erreicht werden. Alle zusätzlich verwendeten Produkte sollten auf einen Einfluss auf die Händedesinfektion untersucht werden, um eine abschwächende Wirkung auszuschließen. Biosorb ist eine Handcreme, die von chirurgischem Personal nach dem Desinfizieren der Hände verwendet wird, um Flüssigkeitsreste aufzunehmen und so das Anlegen der OP-Handschuhe zu erleichtern. Hauptbestandteile des Produktes sind Ethanol und Maisstärke. In der vorliegenden Studie wurde Biosorb auf einen Einfluss auf die Langzeitwirkung der chirurgischen Händedesinfektion untersucht. Ebenfalls untersucht wurde, ob ein Einfluss auf die Handschweißproduktion im Handschuh durch die Anwendung von Biosorb nachweisbar ist. Dieses könnte die Gefahr von Hautschäden durch das im Handschuh herrschende feuchte Milieu vermindern. Es konnte in der vorliegenden mit 26 Probanden durchgeführten Studie nach 90 minütigem Handschuhtragen kein Effekt auf die Bakterienzahlen der Hände durch die Verwendung von Biosorb nachgewiesen werden. Auch die Menge des im Handschuh gebildeten Handschweißes wurde durch Bio-sorb nicht beeinflusst. Da eine Kontamination des OP-Gebiets mit der im Biosorb enthaltenen Maisstärke u.a. zu stärkeinduzierter Peritonitis, Adhäsionen, Wundheilungs-störungen und Tumorzellwachstum führen kann, sollte die Handcreme auf Grund des nicht nachweisbaren Einflusses auf die Schweißproduktion der Hände nicht mehr verwendet werden.
Es handelt sich um eine Anwendungsbeobachtung zur Ermittlung der Anzahl erforderlicher Händedesinfektionen im Stationsalltag anhand der von der WHO definierten Indikationen für die Händedesinfektion.
Bisher liegen Werte zur Häufigkeit der HD nur in der Intensivpflege vor, nicht
aber in sogenannten „Nichtrisikobereichen“, sodass die Bewertung von
Verbrauchsdaten nicht möglich ist.
Erstmalig wurden mit einer Beobachtungsstudie für zwei stationäre
Nichtrisikobereiche Richtwerte zur Anzahl erforderlicher HD und zusätzlich die
Compliance ermittelt.
Es wurden 2424 Indikationen zur HD dokumentiert. Eine Pflegekraft kommt im
Durchschnitt auf 70 (MKG) bzw. 161 (Nephrologie) Indikationen zur HD pro
Arbeitsschicht.
Beim ärztlichen Personal wurden durchschnittlich 16 (Nephrologie) bzw. 17
(MKG) Indikationen pro Arbeitsschicht beobachtet.
Im Mittel ist die Compliance der HD mit 61% auf der MKG-chirurgischen Station
und mit 65% auf der nephrologischen Station > 60%. Mit einem Wert von 66,7%
weist das ärztliche Personal der Nephrologie die höchste Compliance auf,
gefolgt vom ärztlichen Personal der MKG-Chirurgie mit einer Compliance von
66,1%, dem Pflegepersonal der Nephrologie mit 64,7% und der MKG-chirurgischen
Station mit 59,9%.
Nach Auswertung der Apothekenverbrauchswerte konnte gezeigt werden, dass die Compliance durch den Hawthorne-Effekt beeinflusst wurde.
Trotz im Klinikum ausreichend vorhandener Anzahl von Desinfektionsspendern
und Piktogrammen zur richtigen Durchführung der HD sowie geschultem
Personal ist die Compliance mit durchschnittlich 60% auf beiden Stationen
ähnlich hoch wie die Compliance auf Intensivstationen mit durchschnittlich 59%
(Scheithauer et al. 2009). Es wird offensichtlich, dass die Compliance auch in
Nichtrisikobereichen weiter verbessert werden muss.
Gegenstand der Arbeit ist die Kontamination von transdermalen Ultraschallsonden und deren klinische Relevanz. Dabei ist die Arbeit in zwei Teile unterteilt. Im ersten Teil wird ein ausführliches Review zu den relevanten Studien durchgeführt und die Ergebnisse der jeweiligen Studien analysiert und tabellarisch zusammengefasst. Im zweiten Teil werden durch eigenständig durchgeführte Versuche einerseits die Kontamination von transdermalen Sonden an einem Klinikum in einer Stichprobe und im Krankenhausroutinebetrieb untersucht, anderseits die Effektivität eines in Desinfektionsmittel getauchten, für Ultraschallsonden verträglichen Fertigwischtuchs getestet. Im Anschluss erfolgte die Evaluation der Praktikabilität der Wischtücher und der Änderung des Desinfektionsverhaltens des Personals nach Einführung der Wischtücher. Durch die vorliegende Arbeit konnte die klinische Relevanz der Kontamination von Ultraschallsonden und deren Rolle als Vektor bei der Übertragung von Infektionen aufgezeigt werden. Erstmalig liegt mit dieser Arbeit ein ausführliches Review über die bisherige Studienlage vor. Durch die eigenen Untersuchungen konnte die Effektivität der Fertigwischtücher im klinischen Alltag unter Praxisbedingungen getestet werden und unter bestimmten Voraussetzungen als ausreichend befunden werden. Aufgrund der Ergebnisse dieser Untersuchung wurden in der Zwischenzeit Fertigdesinfektionswischtücher für die gesamte Universitätsmedizin zur Desinfektion von Ultraschallsonden eingeführt.
Kontaktlinsenträger haben ein erhöhtes Risiko für Keratitiden. Die Ursache liegt u.a. in unzureichend wirksamen Kontaktlinsenpflegesystemen, insbesondere All-in-One Lösungen. Die vorliegende Studie liefert einen aktuellen Überblick über die meistverwendeten Kontaktlinsenpflegesysteme in Deutschland. Hauptaugenmerk war die Untersuchung unter Belastung mit 1% Albumin, 0,1% Mucin. All-in-One Lösungen wirken weiterhin insbesondere unter Belastung nur unzureichend. Mikrobiologisch sind daher z.Z. nur Wasserstoffperoxidlösung zu empfehlen.
Multiple evidence in animal models and in humans suggest a beneficial role of cold physical
plasma in wound treatment. Yet, risk assessment studies are important to further foster therapeutic
advancement and acceptance of cold plasma in clinics. Accordingly, we investigated the long-term
side effects of repetitive plasma treatment over 14 consecutive days in a rodent full-thickness ear
wound model. Subsequently, animals were housed for 350 days and sacrificed thereafter. In blood,
systemic changes of the pro-inflammatory cytokines interleukin 1β and tumor necrosis factor α
were absent. Similarly, tumor marker levels of α-fetoprotein and calcitonin remained unchanged.
Using quantitative PCR, the expression levels of several cytokines and tumor markers in liver,
lung, and skin were found to be similar in the control and treatment group as well. Likewise,
histological and immunohistochemical analysis failed to detect abnormal morphological changes
and the presence of tumor markers such as carcinoembryonic antigen, α-fetoprotein, or the neighbor
of Punc 11. Absence of neoplastic lesions was confirmed by non-invasive imaging methods such as
anatomical magnetic resonance imaging and positron emission tomography-computed tomography.
Our results suggest that the beneficial effects of cold plasma in wound healing come without apparent
side effects including tumor formation or chronic inflammation.
Vergleich der mikrobioziden Wirksamkeit verschiedener Zahngele in Relation zu einer Zahnpasta
(2012)
Die Mundhöhle stellt ein vielschichtiges Ökosystems für oralpathogene Mikroorganismen dar. Um den negativen Effekten wie Gingivitis, Parodontitis sowie Karies entgegenzuwirken, nehmen die regelmäßige Mundhygiene sowie spezielle Maßnahmen zur Reduktion unerwünschter mikrobieller Spezies einen wichtigen Platz im täglichen Leben ein. Auch auf Grund der zunehmenden Antibiotika-Resistenzentwicklung von Bakterien ist die positive Wirkung von mikrobiozid aktiven Dentalprodukten gegenüber oralpathogenen Mikroorganismen ein bedeutsames Forschungsthema. Die antibakterielle Aktivität verschiedenster Bestandteile in Dentalprodukten sowie der Dentalprodukte als Ganzes wurden in zahlreichen in-vitro und in-vivo Studien untersucht, nachgewiesen und basiert auf verschiedensten Mechanismen. Mit Hilfe eines modifizierten Keimträgertests wurde die mikrobiozide Wirkung von drei unterschiedlichen Chargen des Produkts Ledermix® Fluorid Gel im Vergleich zu Elmex®gelée und Meridol® Zahnpasta untersucht. Die Testung wurde gegenüber einer Hefespezies (C. albicans), einer grampositiven (S. aureus), drei kariogenen grampositiven (S. mutans, S. sanguis, S. pyogenes) und einer pathogenen gramnegativen (P. aeruginosa) Bakterienspezies vorgenommen. Als Ergebnis konnte festgestellt werden, das alle drei Ledermixprodukte bei allen Streptokokkenarten sowie C. albicans eine Reduktion ≥3,5 lg Stufen nach einer Einwirkzeit von 5 min erreichten. Elmex®gelée war gegenüber P. aeruginosa mit einem RF ≥5 lg- Stufen bereits nach 2 min das wirksamste Produkt. Alle Ledermixprodukte zeigten hier lediglich Reduktionen ≥1 lg Stufe. Ledermix® Fluorid Gel erzielte nach der ersten min gegenüber allen Testmikroorganismen (bis auf P. aeruginosa) die besten Ergebnisse. S. aureus war die widerstandsfähigste zu prüfende Mikroorganismenspezies und wurde um nur ≥2 lg Stufen nach mindestens 10 min Einwirkzeit der Dentalgele reduziert. Meridol® Zahnpasta war in dem geprüften Zeitraum vollständig unwirksam gegenüber S. aureus und S. mutans. Diese Zahnpasta erzielte im Vergleich zu den Gelen mit Abstand die schlechtesten Ergebnisse. Es konnte festgestellt werden, dass sich Ledermix® Fluorid Gel und Elmex®gelée insgesamt in ihrer mikrobioziden Wirksamkeit kaum unterschieden. Die mikrobiozide Wirkung der untersuchten Dentalgele ist am ehesten durch den Gehalt an Aminfluorid/Natriumfluorid zu erklären. Dabei haben das Konservierungsmittel und auch das Parfumöl einen nicht unwesentlichen Anteil an der Wirksamkeit.
Die Antiseptika-Forschung ist ein wichtiges Gebiet, aber die Testmethoden sind nur bis zur Prüfstufe des Suspensionstests einheitlich geregelt. Daher sind die Ergebnisse sich in der Testhierarchie anschließender Studien schwierig zu vergleichen und zwingen den Praktiker, Therapieentscheidungen oft auf Basis empirischer Erfahrungen zu treffen. In der vorliegenden Arbeit wurde das Verhalten verschiedener in der klinischen Praxis gebräuchlicher Antiseptika in einem Prüfkörpertest untersucht, der an die Wirksamkeit höhere Anforderungen als der klassische Suspensionstest stellt. Dabei sollte auf dem Prüfkörper zugleich eine für Wunden realitätsnahe Belastung eingesetzt werden. Für die Testung wurden Metallträger mit verschiedenen Erregersuspensionen und Belastungen kontaminiert, angetrocknet und die Wirksamkeit von PVP-Iod und Chlorhexidindigluconat bei verschiedenen Einwirkungszeiten ermittelt. Das erfolgte mit der Zielsetzung festzustellen, ob sich einer der beiden Wirkstoffe als Referenz für künftige Prüfkörpertests eignet. PVP-Iod zeigte in allen Versuchen unabhängig vom Testorganismus (S. aureus, P. aeruginosa und E. faecium) und von der verwendeten Belastung (ohne, MEM + 10 % FBS, 10 bzw. 30 % Vollblut) eine rasch einsetzende, stabile und ausreichende antiseptische Wirkung (ohne Belastung RF > 5, mit Belastung RF > 3 [Pitten et al. 2003]). Das bildete einen deutlichen Kontrast zu den mit Chlorhexidindigluconat erzielten Ergebnissen. Die mit PVP-Iod und Chlorhexidindigluconat gewonnenen Ergebnisse wurden mit den Ergebnissen einer vorangegangenen Studie [Brautferger 2010] zu Octenidindihydrochlorid und Polihexanid verglichen. Auch als Schlussfolgerung dieses Vergleiches kann PVP-Iod als Referenzsubstanz für die Antiseptikatestung empfohlen werden. Obwohl PVP-Iod in Fragen von Verträglichkeit, Remanenz etc. von den neueren Antiseptika übertroffen wird, zeigte kein anderer Wirkstoff in unseren Testungen ein vergleichbar stabiles Wirkungsverhalten. In Verbindung mit der jahrzehntelangen Erfahrung im Einsatz von PVP-Iod kann daher PVP-Iod als Referenzsubstanz für die Antiseptikatestung empfohlen werden.
In der vorliegenden Arbeit wurden Hautveränderungen unter Anwendung eines Pflegetuchs (Bag Bath) an 14 bettlägerigen Patienten über eine Woche untersucht. Zusätzlich wurden in Form eines Fragebogens die Einstellungen und Erfahrungen des Pflegepersonals in Bezug auf die Anwendung des Pflegetuches erfasst. Die Hautveränderungen der Patienten wurden über einen selbstentwickelten Handscore visuell ermittelt. Hierbei fanden die Merkmale Erythem, Rhagade, Bagatellverletzung, Erosion, Schuppung und Trockenheit Berücksichtigung. Der Parameter Trockenheit war im Trend rückläufig, was auf eine erhöhte Hautfeuchtigkeit hindeutet. Bei den übrigen Parametern konnte über den Anwendungszeitraum statistisch keine Veränderung nachgewiesen werden. Zur Objektivierung der Hautparameter wurden zusätzlich ein Cutometer zur Bestimmung der Hautelastizität, ein Reviscometer zur Messung der Schallaufzeit in der Haut, ein Sebumeter zur Bestimmung des Hautfettgehalts und ein Tewameter zur Bestimmung des transepidermalen Wasserverlusts eingesetzt. Hierbei zeigten die Messergebnisse des Reviscometers im Vergleich zur ersten und letzten Messung eine signifikant verringerte Schalllaufzeit. In den übrigen Messverfahren ließen sich statistisch keine Veränderungen nachweisen. An der Erfassung der Einstellungen und Erfahrungen des Pflegepersonals mit Hilfe des Fragebogens beteiligten sich alle Mitarbeiter (n = 30) der Anwendungsbeobachtung. Obwohl im Durchschnitt überwiegend über eine Zeitersparnis und Arbeitserleichterung berichtet wurde, stellte sich eine geringe Veränderungsbereitschaft dar, das neue Produkt in Zukunft anzuwenden. Vor dem Hintergrund aller getätigten Untersuchungen sprechen die Ergebnisse nicht für eine hautschädigende Wirkung durch die Pflegetuchanwendung innerhalb des einwöchigen Messzeitraums. Eine nachfolgende Untersuchung sollte über einen längeren Zeitraum und mit höherer Fallzahl erfolgen. Hierbei wäre es sinnvoll, auch betriebswirtschaftliche und ökologische Aspekte einzubeziehen.
Im klinischen Alltag an deutschen Kliniken spielt die Verhinderung nosokomialer Erkrankungen eine bedeutende Rolle. Infektionen mit sporenbildenden Stäbchenbakterien, besonders die durch C. difficile hervorgerufene C. difficile- assoziierte-Diarrhoe, nehmen als Folge der Antibiotikatherapie zu. Wachsende Virulenz, unvorsichtige Antibiotikaanwendung und zunehmende Multimorbidität der älteren Patienten sorgen für eine erhöhte Anfälligkeit gegenüber sporenbildende Bakterien, was zu wachsenden Problemen in der Versorgung schwerkranker und älterer Mensch führt, verbunden mit erhöhter Morbidität und Letalität. Bezüglich der Suszeptibilität von Sporenbildnern gegenüber Händedesinfektionsmitteln ist die Datenlage für praxisnahe Studien unbefriedigend. Daher wurde in der vorliegenden Studie die Wirksamkeit eines Peressigsäure basierten Desinfektionsmittels, die Kombination von Peressigsäure mit Wasserstoffperoxid, Wasserstoffperoxid allein, Poly Alcohol Hände Antisepticum sowie Kaliseife gegen Bakteriensporen verglichen. Testorganismus war Bacillus subtilis (atropheus), ein apathogener, grampositiver, stäbchenförmiger, aerob wachsender Endosporenbildner. Dem Studiendesign wurde die DIN EN 1500 in modifizierter Form zugrunde gelegt. Der wesentliche Unterschied bestand in der Verwendung steriler Probebeuteln, in denen die ganze Hand anstatt nur der Fingerkuppen zur Bestimmung des Vor- und Nachwerts bewegt wurde. Die Einwirkzeit der Desinfektionsmittel betrug 30 s. Kaliseife wurde nach 30 s Anwendung unter laufendem Wasser abgespült. Pro Präparat erfolgte die Prüfung an 15 freiwilligen Probanden im Lateinischen Quadrat. Für alle Präparate konnte keine ausreichende Wirksamkeit im Sinne einer log-Stufen-Reduktion um mindestens drei Stufen gegenüber den Bakteriensporen festgestellt werden. Es konnte nur gezeigt werden, dass Peressigsäure und Peressigsäure in Kombination mit Wasserstoffperoxid sowie Kaliseife die Kontamination am effektivsten reduzierten. Als Fazit ist die sporozide Händedesinfektion als nicht ausreichend für die Prophylaxe der Weiterverbreitung von Sporen über die Hand anzusehen, so dass die Notwendigkeit für weiterführende Untersuchungen zur Sporenelimination besteht. Als geeignete Schutzmaßnahmen ist das Tragen von Schutzhandschuhen mit nachfolgender hygienischer Händedesinfektion mit einem Peressigsäure-basierten Desinfektionsmittel zu empfehlen
Das Tragen textiler Unterziehhandschuhe ist eine Möglichkeit zur Verringerung feuchtigkeitsbedingter Hautschäden. Mit dieser Machbarkeitsstudie sollten Erfahrungen mit dem Einsatz textiler aufbereitbarer Unterziehhandschuhe im stationären Pflegebereich gesammelt und dabei insbesondere Fragen zur Logistik, Kosten, Trageeigenschaften und Akzeptanz beantwortet werden. Über drei Monate wurde auf einer Intensivpflegestation der Einsatz von Unterziehhandschuhen mit 18 Mitarbeitern getestet. Nach jedem Tragen wurden mittels Dokumentationsbogen Angaben zur Nutzung und Akzeptanz standardisiert abgefragt. Die Handschuhe wurden als Netzwäsche gemäß den Richtlinien für die Aufbereitung von Krankenhauswäsche aufbereitet und erneut zur Nutzung bereitgestellt. Während und zum Ende der Studie wurden die teilnehmenden Mitarbeiter im Rahmen einer Fragebogenerhebung ausführlich hinsichtlich ihrer Erfahrungen zur Anwendung der Baumwoll-Unterziehhandschuhe und ihrer persönlichen Beurteilung bezüglich der Trageeigenschaften befragt. Während der Studiendauer wurden 2165 Anwendungen mit einer nötigen Umlaufmenge von 687 Paar Handschuhen dokumentiert. Daraus ergab sich ein Tagesverbrauch von durchschnittlich 4 Paar pro Person. Die durchschnittliche Tragedauer betrug 28,6 min. Die Unterziehhandschuhe zeigten sich von den Trageeigenschaften und der Aufbereitbarkeit als geeignet. Die aufbereitungsbedingte Materialermüdung war gering und führte nicht zum Verlust der Trageeigenschaften; nur wenige Handschuhe mussten aussortiert werden. Bei Studienende waren noch 90,5 % der Handschuhe vorhanden und weiter einsetzbar. Die Anschaffungs- und Aufbereitungskosten betrugen für die gesamte Umlaufmenge von 687 Paar Handschuhen 973,20 Euro bzw. 0,45 Euro pro Anwendung, wenn man von einer vollständigen Abschreibung der Handschuhe mit Studienende ausgeht. Die tatsächlichen Kosten unter Einbeziehung des Restwertes der Handschuhe sind entsprechend geringer. Die Akzeptanz und Compliance zur Nutzung der Unterziehhandschuhe war bemerkenswert gut. Das lag zum einen an den Eigenschaften der Handschuhe, zum anderen an der Reduktion des Schwitzens und dem positiv empfundenen Einfluss auf die Haut der Hände. Mit der Studie konnte die Durchführbarkeit des routinemäßigen Einsatzes textiler Unterziehhandschuhe als Hautschutzmaßnahme gezeigt werden. Bei bedarfsgerechter Bereitstellung und mit entsprechender Erfahrung in der Anwendung ist die praktische Nutzung von Unterziehhandschuhen unkompliziert realisierbar. Voraussetzung sind die Aufklärung der Anwender und die Implementierung der Logistik der Aufbereitung.
Zielsetzung: Die Bereitstellung von Wasser mit Trinkwasserqualität ohne Gehalt an Trinkwasserpathogenen ist für immunsupprimierte Patienten von entscheidendem Einfluss auf die Mortalität und Letalität. Deshalb wurde in einer prospektiven Studie die Effizienz eines neu entwickelten aufbereitbaren Point-of-use Filters (Germlyser®, Aquafree GmbH, Hamburg) geprüft. Methode: Die Studie umfasste 4 Versuchsserien. In Versuchsserie 1 wurden die Filter nach einer Filterstandzeit von 7 d manuell, in Versuchsserie 2 maschinell in einem RDG aufbereitet. Nach der Aufbereitung wurden die Filter auf Leckage geprüft und in sterilen Behältern zwischengelagert. In Versuchsserie 3 wurde die Standzeit der Filter auf bzw. 4 Wochen verlängert und analog wie in Versuchsserie 2 aufbereitet. Versuchsserie 4 unterschied sich von Versuchsserie 3 durch den Einsatz eines im Gehäuse veränderten Filters und die auf 8 Wochen verlängerte Standzeit. Insgesamt wurden 12 Zapfeinrichtungen und 6 Brauseköpfe beprobt. In Versuchsserie 2 wurden 78 Proben von 6 Zapfeinrichtungen aus den Badezimmern der Patientenzimmer gezogen. Die Proben wurden jeweils direkt vor dem Filterwechsel gewonnen. Während Versuchsserie 1 mit wöchentlichem Filterwechsel über 3 Wochen durchgeführt wurde, beinhaltete Versuchsserie 2 13 Probennahmen mit jeweils wöchentlichem Filterwechsel im Verlauf von 7 Wochen, danach monatlich über 6 Monate. In Versuchsserie 3 wurden die Proben bei monatlichem Filterwechsel wöchentlich über 3 Monate gesammelt und in Versuchsserie 4 bei Filterwechsel nach 2 Monaten nach 2, 4 und 8 Wochen. Zur Probennahme wurde die erste auslaufende Wasserportion ohne vorheriges Abflammen des Wasserauslasses in einem sterilen Probennahmegefäß aufgefangen. Untersucht wurde auf Gesamtkoloniezahl bei 22 und 36 °C, coliforme Bakterien, P. aeruginosa, Fäkalstreptokokken, Legionella spp. und Schimmelpilze entsprechend Anlage 1 Nr. 5 der TrinkwV (1990), DIN EN 12780, der Empfehlung des Umweltbundesamts (2000) sowie gemäß Daeschlein et al. (2008). Ergebnisse: Während die manuelle Aufbereitung zur Verkeimung der Filter führte, gewährleistete die maschinelle Aufbereitung die sichere Dekontamination der Filter. Das gefilterte Wasser erfüllte die Anforderungen der Deutschen TrinkwV ebenso wie der die WHO Leitlinie, d. h. kein Nachweis von Wasserpathogenen und Koloniezahl < 100/ml. Die Wiederaufbereitungsintervalle konnten von 1 bis auf 8 Wochen ausgedehnt werden.
Hygiene ist ein unentbehrlicher Bestandteil des alltäglichen Praxisablaufs, der zum Schutz vor Infektionen dient. Mit der Überarbeitung der Hygienerichtlinie des Robert Koch-Instituts (RKI) im Jahr 2006 kam es zu einer Erhöhung der Anforderungen an die Hygiene und den Infektionsschutz in der Zahnarztpraxis. Die Analyse der Entwicklung der Ausgaben für Hygieneaufgaben einer zahnärztlichen Gemeinschaftspraxis mit 2 Behandlern in Berlin im Zeitraum 2006 bis 2010 zeigte eine kontinuierliche Steigerung der Ausgaben um etwa 37 %. Eine Besonderheit stellt dabei der starke Anstieg zwischen 2006 und 2007 dar, was auch auf die verschärften Hygienerichtlinien zurückführen ist. Die hohen Kostensteigerungen die in anderen Studien aus den Jahren 1996 und 2006 ermittelt wurden, konnten durch die vorliegende Untersuchung nicht bestätigt werden.
In dieser Arbeit wurde die Wirksamkeit der Antiseptika Chlorhexidindigluconat CHX 0,0001 % u. 0,00000625 %), Polihexamethylenbiguanid (PHMB 0,0001 % u. 0,000025 %) und Octenidinhydrochlorid (OCT 0,0002 % u. 0,00005 %) mit gewebekompatiblen Atmosphärendruckplasmen (TTP) mit dem Edelgas Argon als Trägergas mit und ohne Zumischung von 1% Sauerstoff, generiert mit dem kINPen09 und einer Hohlelektroden-Dielectric-Barrier Discharge Plasmaquelle (HDBD) sowie der alleinigen Gasbehandlung (Trägergas ohne Plasmagenerierung) in Bezug auf die Vermehrungshemmung bzw. Eradikation von C. albicans ATCC 10231, C. albicans SC 5314, P. aeruginosa ATCC 9027, P. aeruginosa SG 81, S. epidermidis ATCC 12228, S. epidermidis RP 62A, S. mutans DSM 20523 und S. sanguinis DSM 20068 untersucht. Die Antiseptika wirkten über den gesamten Untersuchungszeitraum von 32 h auf die Mikroorganismen ein, die TTP-Behandlungen nur 60 s. Die Vermehrung der Mikroorganismen wurde alle 30 min anhand der optischen Dichte der Testkulturen gemessen und die Fläche unter dem resultierenden Graphen (Area under the curve, AUC) charakterisiert. Bei C. albicans ATCC 10231 und SC 5314 wurde die Vermehrung vollständig von OCT 0,0002 % und der Plasmabehandlung mit HDBD mit Sauerstoffzuführung gehemmt. Die HDBD-und kINPen09- Behandlungen ohne Sauerstoffzufuhr waren beim ATCC-Stamm nur unwesentlich weniger effektiv. Die restlichen Antiseptika zeigten nur eine geringe Wirkung. Bei der Behandlung von P. aeruginosa SG 81 kam es weder durch die verwendeten Antiseptika noch durch das Plasma zu einer vollständigen Vermehrungshemmung. Insgesamt stellten sich hier die Plasmabehandlungen als deutlich effektiver heraus als die Behandlungen mit den Antiseptika. Auch bei P. aeruginosa ATCC 9027 zeigte die Behandlung mit den Antiseptika einen geringeren Effekt. Im Ganzen reagierten die gramnegativen P. aeruginosa in diesen Versuchen am wenigsten empfindlich auf die antiseptischen Behandlungen. Bei der Behandlung von S. epidermidis RP 62A bewirkten die Antiseptika PHMB 0,0001 % und OCT 0,0002 % eine vollständige Vermehrungshemmung. Die Argongaskontrolle und die Plasmabehandlung mit dem kINPen09 waren ebenso wie die Behandlung mit CHX 0,0001 % etwas weniger wirksam. Beim nicht biofilmbildenden ATCC 12228 Stamm von S. epidermidis, der nicht mit Plasma behandelt wurde, führte nur OCT 0,0002 % zu einer vollständigen Vermehrungshemmung. Bei S. mutans DSM 20523 konnte keine der untersuchten antiseptischen Behandlungen zu einer vollständigen Vermehrungshemmung führen. Am effektivsten stellten sich die Behandlungen mit OCT, PHMB und die Plasmaanwendung mit dem kINPen09 ohne und mit 1 % Sauerstoffbeimischung heraus. Die Behandlung von S. sanguinis DSM 20068 wurde ausschließlich mit Plasma bzw. deren Gaskontrollen durchgeführt. Hier waren die Plasmabehandlungen mit dem kINPen09 und deren Gaskontrollen den HDBD-Behandlungen überlegen. Von allen getesteten Antiseptika stellte sich Octenidin 0,0002 % als das am breitesten wirksame und effektivste Antiseptikum heraus. Bei der Behandlung der Candida- und S. epidermidis-Stämme führte dies zu einer vollständigen Hemmung der Proliferation bis zum Ende des Beobachtungszeitraums von 32 h. CHX 0,0001 % und PHMB 0,0001 % unterschieden sich bis auf die Behandlung von S. epidermidis RP 62A und S. mutans DSM 20523 mit der Überlegenheit für PHMB 0,0001 % nicht in ihrer Wirksamkeit. Die Plasmabehandlungen von 60 s waren mit Ausnahme von S. epidermidis den über den gesamten Untersuchungszeitraum einwirkenden Antiseptika ebenbürtig oder signifikant überlegen. Die Behandlung mit TTP könnte damit eine wirksame Alternative oder Ergänzung zu den herkömmlichen Antiseptika darstellen, um z.B. die Vermehrung von Mikroorganismen in einer infizierten Wunde zu hemmen und somit die Immunabwehr zu unterstützen und Entzündungen zu verzögern oder zu verhindern.
Um die Iodversorgung der Neugeborenen im Raum Vorpommern zu bewerten, wurde die Iodausscheidung von 418 gesunden Neugeborenen, die zwischen Mai 2005 und April 2007 in der Greifswalder Universitätsfrauenklinik geboren wurden, analysiert. 87 % der untersuchten Neugeborenen schieden > 10 µg Iod/dl Urin aus. Die mittlere Iodurie unterschied sich bei Kindern von Müttern, die während der Schwangerschaft zusätzlich Iod supplementiert hatten nur geringfügig von der Iodurie bei Kindern, deren Mütter während der Schwangerschaft kein zusätzliches Iod eingenommen hatten. Die Mediane lagen bei 20,1 µg/dl und 17,8 µg Iod/dl Urin. Das ist ein Zeichen dafür, dass sich die Iodausscheidung in den letzten Jahren deutlich verbessert hat und Neugeborene in der Region Vorpommern nach den WHO-Kriterien heute ausreichend mit Iod versorgt sind. Allerdings schieden bereits 54 % der untersuchten Neugeborenen > 20 µg Iod/dl Urin aus, was bereits die Gefahr einer Iodüberdosierung kennzeichnet.
Die Hände des medizinischen Personals gelten als Hauptvehikel für die Übertragung nosokomialer Pathogene. Daher nimmt die Händedesinfektion die wichtigste Stellung in der Prävention nosokomialer Infektionen ein. Die beruflich bedingte umfangreiche Exposition des medizinisch tätigen Personals mit den in Händedesinfektionsmitteln verwendeten niederen Alkoholen Ethanol, Propan1ol und Propan-2-ol erfordert die Gewährleistung einer vollständigen Anwendungssicherheit. Für Ethanol basierte Desinfektionsmittel konnte eine toxikologisch relevante Resorption ausgeschlossen werden. Aufgrund der begrenzten Datenlage über das Resorptionsausmaß bei der fachgerechten Anwendung von Propanolen erfolgte eine die Alltagsbedingungen im klinischen Operationsbereich simulierende Studie mit standardisierter Durchführung einer einmaligen hygienischen und dreimaligen chirurgischen Händedesinfektion. Da bis zum jetzigen Zeitpunkt keine Differenzierung zwischen inhalativer und dermaler Resorption vorgenommen wurde, erfolgte die Händedesinfektion unter Ausschluss der inhalativen Resorption von Alkoholdämpfen durch die Verwendung von Gesichtsmasken in Kombination mit Filtern. Ein identisches Studiendesign zu einer Vorläuferstudie ohne Trennung von dermaler und pulmonaler Resorption ermöglicht erstmals eine vergleichende Einschätzung beider Resorptionsrouten. Bei zehn Probanden wurden die Blutserumspiegel bei Verwendung drei verschiedener propanolhaltiger Desinfektionsmittel (Gehalt von 70 % [w/w] Propan-1-ol, 63,14 % [w/w] Propan-2-ol, 30 % [w/w] Propan-1-ol und 45 % [w/w] Propan-2-ol) bestimmt. Je Proband kam an drei verschiedenen Tagen jeweils ein Desinfektionsmittel zum Einsatz. Auch unter Ausschluss der pulmonalen Resorption konnten unabhängig vom verwendeten Präparat signifikante Serumspiegel ermittelt werden. Die maximale mediane Blutkonzentration wurde bei der Verwendung der Präparate mit Gehalt nur eines Wirkstoffs für Propan-1-ol mit 1,16 mg/l und für Propan-2-ol mit 1,74 mg/l bestimmt. Bei der Anwendung des Kombinationspräparats traten maximale mediane Propan-1-ol-Konzentrationen von 0,68 mg/l und Propan-2-ol-Spiegel von 1,24 mg/l auf. Ein signifikanter Anstieg der Metaboliten der Propanole Aceton und Propionaldehyd wurden nicht festgestellt. Damit kam es zu keinem Zeitpunkt zu einer Überschreitung toxikologisch bedenklicher Serumspiegel. Der Vergleich zur Vorstudie mit dermaler und pulmonaler Resorption erbrachte für die Anwendung des ausschließlich Propan-1-ol enthaltenden Präparats eine signifikant niedrigere Aufnahme des Alkohols. Dieses Ergebnis bestätigte sich bei der Anwendung des Kombinationspräparats aufgrund der gegenseitigen Beeinflussung der Propanole und der daraus resultierenden vornehmlich dermal erfolgenden Resorption allerdings nicht. Die Aufnahme von Propan-2-ol scheint vermehrt über die dermale Resorptionsroute zu erfolgen, da weder bei der Anwendung des Präparats mit Propan-2-ol noch bei der Anwendung der Wirkstoffkombination eine signifikante Verminderung der resorbierten Menge im Vergleich zur Vorstudie analysiert werden konnte. Die vorliegende Studie lässt aufgrund der zahlreichen variablen Einflüsse und der begrenzten Probandenanzahl keine allgemeingültige Aussage über die vorherrschenden Resorptionsrouten der Propanole und die gegenseitige Beeinflussung ihres Resorptionsverhaltens zu und macht weiterführende Studien erforderlich.
Zusammenfassung Die Förderung der Wundheilung durch pulsierenden Gleichstrom insbesondere bei chronischen Wunden ist ein aktuelles Forschungsthema mit wachsender Bedeutung. Gegenüber Bakterien sind bisher überwiegend bakteriostatische Effekte in vitro und in vivo im Tiermodell nachgewiesen. Das Ausmaß der bakterioziden Wirksamkeit wurde jedoch bisher nicht untersucht. Bei Anwendung des Dermapulse®-Verfahrens wurden die untersuchten Bakterienspecies (Escherichia coli, Staphylococcus aureus, Pseudomonas aeruginosa, Enterococcus faecium, Klebsiella pneumoniae und Staphylococcus epidermidis, MSSE) signifikant (p<0,01) reduziert. Dabei wurde die stärkste Reduktion gegenüber E. coli (mittlerer Reduktionsfaktor 0,8 lg), die geringste gegenüber MSSE (mittlerer Reduktionsfaktor 0,2 lg) ermittelt. Die Reduktion fiel zwischen positiver und negativer Polarität signifikant unterschiedlich aus, wobei die stärkere Wirkung bei positiver Polarität nachweisbar war. Im Vergleich zur mikrobioziden Wirkung eines Antiseptikums ist die bakteriozide Wirkung des pulsierenden Gleichstroms, obwohl sie gegen alle geprüften Bakterien signifikant nachweisbar ist, gering. Auf Grund der biologischen Wirkungen der Elektrostimulation auf die Wundheilung ist jedoch anzunehmen, dass die günstige Wirkung der Elektrostimulation durch deren direkte bakteriozide Wirkung noch verstärkt wird.
An zwei modernen Dentaleinheiten der Firmen KaVo und Sirona aus dem ZZMK der Universität Greifswald wurde der endständige Einweg-Membranfilter „Germlyser® ENT“ auf seine Filterleistung untersucht, Kühl- und Spülwasser gemäß den RKI-Richtlinien mit Gesamtkoloniezahlen < 100 KBE/ml zu erzeugen. Im Verlauf der Untersuchungen konnte festgestellt werden, dass die derzeit übliche Betriebswasseraufbereitung mit H2O2 keine zufriedenstellenden Ergebnisse liefert. Der Richtwert von 100 KBE/ml wurde bereits 2 d nach chemischer Intensivdekontamination überschritten. Die Wasseraufbereitung durch den Germlyser® ENT Membranfilter konnte an allen Arbeitsenden beider Dentaleinheiten für 7 d hygienisch einwandfreies Wasser produzieren. Die vom Filterhersteller angegebene Standzeit von 3 Monaten konnte allerdings nicht erreicht werden. Durch zusätzliche Desinfektion des Mikromotors an der KaVo Dentaleinheit konnte die Wasserqualität verbessert und die Standzeit des Filters verlängert werden. Die Gesamtkoloniezahl nach 28 d betrug 72 KBE/ml. Gerätekupplungen, Mikromotoren und Luft-Wasser-Spritzen, für die bisher keine Aufbereitungsmaßnahmen vorgesehen sind, konnten als mögliche Kontaminationsquelle für das Kühlwasser identifiziert werden. Die fehlende Filtrationsmöglichkeit am Spülbecherauslass zieht eine starke Verunreinigung des Spülbecherwassers nach sich. Als alleinige Wasseraufbereitungsmethode in Dentaleinheiten ist der Germlyser® ENT Membranfilter in seiner untersuchten Form daher nicht geeignet. Ergänzend zu systemischen Maßnahmen kann der Filter die Wasserqualität verbessern.
Akute traumatische Wunden sind mit Bakterien kontaminiert und haben ein Infektionsrisiko von etwa 6 %. Daher wird die antiseptische Wundspülung vor chirurgischer Versorgung kontaminierter Wunden empfohlen. Hierfür werden unterschiedliche Antiseptika eingesetzt. Das Ziel dieser retrospektiven, nicht randomisierten Längskohorten-Studie bestand darin, den präventiven Effekt von vier verschiedenen Spüllösungen vor chirurgischer Behandlung auf die SSI-Rate bei traumatischen Weichteilwunden zu ermitteln.
Über einen Zeitraum von drei Jahrzehnten wurde die prophylaktische Wundspülung bei Patienten mit kontaminierten traumatischen Wunden untersucht, die eine chirurgische Behandlung mit oder ohne primären Wundverschluss benötigten. Von 1974-1983 wurde entweder PHMB, PVP-I, 4 % Wasserstoffperoxid, oder unverdünnte Ringerlösung verwendet. Von 1984-1996 wurden nur PHMB oder PVP-I angewendet. Von 1997 bis Ende der Studie 2005 wurde nur noch PHMB angewendet.
Die kombinierte Rate von oberflächlichen und tiefen Wundinfekten betrug 1,7% in der PHMB-Gruppe, 4,8% in der PVP-I-Gruppe, 5,9% in der Ringer-Gruppe, und 11,7% in der Wasserstoffperoxid-Gruppe. Verglichen mit allen anderen Behandlungsgruppen zeigte PHMB die höchste Effizienz, um Infektionen in traumatischen Weichteilwunden vorzubeugen. Bei Riss-Quetsch-Wunden war der Unterschied verglichen mit PVP-I nur für die tiefen Wundinfektionen signifikant. Bei Schnittwunden wurden sowohl A1- als auch A2-SSI signifikant in der Häufigkeit reduziert.
Auf Grund des Stichprobenumfangs ist trotz des retrospektiven Studiendesigns kein Zweifel an der infektionspräventiven Überlegenheit von PHMB zur Spülung bei traumatischen Weichteilwunden gegeben. Die Infektionsraten der retrospektiven Studie können als Basis für die Fallzahlkalkulation für eine dringend benötigte prospektive klinische Studie zugrunde gelegt werden.
Zielstellung: Ziel dieser Studie war es herauszustellen, ob die Notwendigkeit einer strikten räumlichen oder zeitlichen Trennung von septischen und aseptischen Operationen bezüglich einer möglichen Patientengefährdung durch freigesetzte aerogene Mikroflora besteht. Methode: Über einen Zeitraum von acht Wochen wurden 14 aseptische und 16 septische Operationen der Allgemein- und Viszeralchirurgie in zwei baulich vergleichbaren OP-Sälen ohne RLTA hinsichtlich der Art und Menge der mikrobiellen Raumluftbelastung untersucht. Für den Vergleich der Luftqualität wurden drei Arten von Messungen durchgeführt, Luftkoloniezahlmessungen mittels Air-Sampler, Sedimentationsuntersuchungen und Kontaktkulturuntersuchungen mittels Blutagarplatten. Die Unterschiede im Erregerspektrum beider Gruppen waren mit Ausnahme der für die Risikobewertung irrelevanten aeroben Sporenbildner nicht signifikant. Die Anzahl bei septischen Eingriffen in die Raumluft freigesetzter Gram-negativer Bakterien war so gering (durchschn. KbE pro min bei Proteus mirabilis 0,095, Escherichia coli 0,077, Enterococcus faecalis 0,016), dass in keinem Fall deren Nachweis auf Umgebungsflächen (OP-Wände) gelang. Selbst in 1 m Entfernung vom OP-Feld gelang nur einmal der Nachweis von 2 KbE E. coli, aber nicht von anderen Gram-negativen Bakterien. Ein Nachweis Gram-negativer Bakterien 30 min nach dem Ende einer OP in der Raumluft gelang nur in geringen Mengen (insg. 16 KbE/m³). Bei der Interpretation der Ergebnisse ist zu berücksichtigen, dass sie in einem OP ohne RLTA generiert wurden. Da bei zwei OP´s, wenn auch in geringen Mengen, Gram-negative Bakterien 30 min nach dem OP-Ende in der Raumluft nachweisbar waren, ist in Operationseinrichtungen ohne RLTA die räumliche Trennung septischer und aseptischer Operationen aus Sicherheitsgründen zu empfehlen. Sofern allerdings die deklarierte Einwirkungszeit der Flächendesinfektion eingehalten wird, ist bei Verzicht auf räumliche Trennung eine Wechselzeit nach septischen Eingriffen > 30 min als ausreichend anzusehen. Aufgrund der Leistungsfähigkeit moderner RLTA, potentiell infektiösen Erreger in der Raumluft in weniger als 25 min auf 1 % der Ausgangsmenge zu reduzieren, ist in OP-Einheiten mit RLTA keine Notwendigkeit zur räumlichen Trennung von septischen und aseptischen Operationen gegeben. Ergebnisse: Luftkoloniezahlmessungen (KbE/m³ septisch 401,8 vs. aseptisch 388,2) und Sedimentationsuntersuchungen (KbE/min/m² septisch 53,4 vs. aseptisch 54,4) sowie Kontaktkulturuntersuchungen wiesen in der quantitativen Gesamtbetrachtung der Erregerfreisetzung keine signifikanten Unterschiede auf. Bezüglich der Luftkoloniezahlmessungen konnten zu gewissen OP-Zeitpunkten Unterschiede beim Erregervorkommen zwischen beiden OP-Gruppen beobachtet werden. Das betraf besonders kurze Operationen.
The objective of the present investigation was to examine the residual antimicrobial activity after a topical exposure of reconstructed human epidermis (RHE) to equimolar solutions of either chlorhexidine digluconate (CHG, 0.144% w/v) or octenidine dihydrochloride (OCT, 0.1% w/v) for 15 min. RHE-associated antiseptic agents were more effective on Staphylococcus aureus than on Pseudomonas aeruginosa. S. aureus was not detected after 24 h of contact, which demonstrated a microbicidal efficacy of greater than 5-log<sub>10</sub> reduction. In contrast, P. aeruginosa was reduced by approximately 2 log<sub>10</sub> at the same incubation time, which parallels the growth of the initial inoculum. This result could be interpreted either as a microbiostatic effect or as an adherence of P. aeruginosa to a low positively charged surface. Small amounts of CHG and OCT can penetrate the stratum corneum. Using these antiseptic agents, the viability of keratinocytes was reduced to 65-75% of that of the untreated RHE control following 24 h incubation in the presence of test microorganisms. With consideration of antimicrobial activity and cytotoxic effect, OCT corresponds better to a biocompatible antiseptic agent than CHG.
Hintergrund: Nosokomiale Infektionen einschließlich postoperativer Wundinfektionen sind eines der gravierendsten Probleme der modernen Medizin. Sie sind assoziiert mit erhöhter Morbidität, Kosten und verlängerten Krankenhausliegezeiten. Material und Methode: Als Teil unseres „safe surgery bundle“ zur Überprüfung der Einhaltung von Basishygienemaßnahmen in der postoperativen Betreuung wurde ein Fragebogen zur Beantwortung durch Patienten erstellt, der Fragen zur Wahrnehmung des Hygienemanagements und zur Aufklärung in Bezug auf postoperative Wundinfektionen enthält. Hierdurch erhält der Patient die Möglichkeit, die Einhaltung ausgewählter Hygienemaßnahmen zum Zeitpunkt der Entlassung zu bewerten. Ergebnisse: Die Auswertung zeigt, dass der Fragebogen Interesse bei den Patienten weckt (Rücklaufquote = 69,3 %, n = 88) und plausible Ergebnisse liefert. Zufrieden stellend sind insbesondere die Angaben zum Hygieneverhalten des Pflegepersonals und der Ärzte. Verbesserungsmöglichkeiten zeigen sich bei der Patienten-Information und der Arbeit des Reinigungsdienstes. Schlussfolgerung: Den detektierten Problemen sollte entgegengewirkt werden. Mangels direkter Vergleichbarkeit mit Angaben aus der Literatur aufgrund fehlender analoger Studien könnte ein auf Grund der Erfahrungen verbesserter Fragebogen in der Zukunft eingesetzt werden, um erreichte Verbesserungen zu erfassen. Eine Ausweitung der Befragung auf andere Kliniken und Stationen wird als sinnvoll erachtet.
There has been a substantial evolution of anti-cancer therapies in the last decade, leading
to improved prognosis and disease-free survival of patients with melanoma. Due to the
number of patients that still develop resistance or to the high systemic toxicity and side
effects, new treatment options are still needed. Regardless of the type of therapeutic
interventions (except surgery), the reactive oxygen species (ROS) are a by-product or
contribute to the action mechanism of many successful therapies. In this context, medical
cold atmospheric plasma (CAP) arises as a promising tool, and studies are important to
prove the effectiveness of this new device.
Since combination therapies are the current standard way to treat melanoma, we explored
candidates to be combined with cold atmospheric plasma, with potential to become a
therapeutic option in the combination. Here, we tested the radiotherapy and clinically safe
mitochondrial inhibitor drugs. In the end of the study, both, ionizing radiation and four
mitochondrial-targeted-drugs showed to be promising candidates for the combination with
CAP. These combinations induced increased cytotoxicity and modulated the immune
system improving the anti-tumor immune response. Mitochondrial damage seems to be
the first stage to induce cellular deficiency and culminate in apoptotic cell death.
Furthermore the release of GM-CSF contribute to a pro inflammatory state and immune
system activation.
This dissertation showed that CAP serves as an excellent tool to boost melanoma cell
death and induce anti-tumor response. In addition, in our proposed therapeutic
combination, the intensity of plasma treatment could be decreased possibly resulting in
less systemic toxicity. Our results serves as model to be studied in other tumor entities.
Die Inaktivierung von Bakterien durch Antiseptika, z. B. auf chronischen Wunden ist unter anderem aufgrund der Bildung von Biofilmen erschwert. Ebenso stellt die Entwicklung von Resistenzen gegenüber Antibiotika ein immer größer werdendes Problem bei der Behandlung von Infektionen dar. Zudem ist die antimikrobielle Behandlung nur ein Teilaspekt, um chronisch infizierte Wunden in einen regenerativen Heilungsprozess zu überführen. Daher sind neue, alternative Behandlungsstrategien von hoher Bedeutung. Hierfür scheint physikalisches Plasma aufgrund seiner antimikrobiellen wie auch wundheilungsfördernder Wirkungsweise eine aussichtsreiche Perspektive darzustellen. Zur Erzeugung von sog. Tissue Tollerablen Plasma (TTP) stehen verschiedene Plasmaquellen zur Verfügung, die zur Anwendung gegen Mikroorganismen in Biofilmen in Frage kommen. In der vorliegenden Arbeit wurden der kinpen09 und zwei Dielektrisch-Behinderte-Oberflächen-Entladungs-Quellen, die Conplas- und die Epoxidharz-Plasmaquelle, auf ihre antimikrobielle Wirkungsweise mit Argonplasma mit und ohne Sauerstoffbeimischung und mit Luftplasma v. a. an Biofilmen mit P. aeruginosa SG81 und S. epidermidis RP62A untersucht. Mit dem kinpen09 wurde zusätzlich die antimikrobielle Effektivität von Plasma mit Helium oder Stickstoffbeimischungen getestet. Bei Einsatz des kinpen09 zeigte sich Argon als das antimikrobiell effektivste Trägergas. Bei der Epoxidharz-Plasmaquelle war Luftplasma am wirksamsten. Bei der Conplas sind Luft- und Argonplasma etwa gleich effizient gegen mikrobielle Biofilme. Die Reduktionsraten bei Argonplasma mit dem kinpen09 und Conplas lagen nach 300 s Expositionszeit bei P. aeruginosa bei ca. 5 log10 und mit dem kinpen09 bei S. epidermidis bei 3 log10. Diese Reduktionsraten übersteigen mit Ausnahme von 300 s Ar+O2-Plasma (kinpen09) die Wirksamkeit von Chlorhexidin (0,1 %), einem Standard-Antiseptikum zur Behandlung von Biofilmen, nach 10 min Behandlungsdauer von ca. 1,5 log10 signifikant (p < 0,005). In Übereinstimmung zur Literatur lässt sich aus den Ergebnissen ableiten, dass v. a. Sauerstoffradikale für die antimikrobielle Wirksamkeit verantwortlich sind. Neben der alleinigen Anwendung von TTP könnten Kombinationsbehandlungen mit Antiseptika aussichtsreiche Verfahren zur gezielten Inaktivierung von Mikroorganismen in Biofilmen und zur Modulation von Wundheilungsprozessen darstellen.
Because of its antimicrobial properties, nonthermal plasma could serve as an alternative to chemical antisepsis in wound treatment. Therefore, this study investigated the inactivation of biofilm-embedded Pseudomonas aeruginosa SG81 by a surface barrier-discharged (SBD) plasma for 30, 60, 150 and 300 s. In order to optimize the efficacy of the plasma, different carrier gases (argon, argon admixed with 1% oxygen, and argon with increased humidity up to approx. 80%) were tested and compared against 0.1% chlorhexidine digluconate (CHG) exposure for 600 s. The antimicrobial efficacy was determined by calculating the difference between the numbers of colony-forming units (CFU) of treated and untreated biofilms. Living bacteria were distinguished from dead by fluorescent staining and confocal laser scanning microscopy. Both SBD plasmas and CHG showed significant antimicrobial effects compared to the untreated control. However, plasma treatment led to a higher antimicrobial reduction (argon plasma 4.9 log<sub>10</sub> CFU/cm<sup>2</sup>, argon with admixed oxygen 3 log<sub>10</sub> CFU/cm<sup>2</sup>, and with increased gas humidity 2.7 log<sub>10</sub> CFU/cm<sup>2</sup> after 300 s) compared to CHG. In conclusion, SBD plasma is suitable as an alternative to CHG for inactivation of Pseudomonas aeruginosa embedded in biofilm. Further development of SBD plasma sources and research on the role of carrier gases and humidity may allow their clinical application for wound management in the future.
Einfluss der Plasmabehandlung auf das transepidermale Penetrationsverhalten von Arzneistoffen
(2021)
Zusammenfassung und Ausblick
Die Forschungshypothese, dass eine Plasmabehandlung der Haut mit kaltem
Atmosphärendruckplasma zu einer lokalen Änderung der physikochemischen Eigenschaften des
Stratum corneum und dessen Struktur und (Barriere-)Funktion führt, konnte bestätigt werden.
Im Rahmen der vorliegenden Arbeit wurden morphologisch sichtbare Hautveränderungen, die
Penetrationseigenschaften verschiedener Substanzen vor und nach Plasmabehandlung sowie
Veränderungen der Lipidzusammensetzung des Stratum corneum auf molekularer Ebene analysiert.
Der wesentliche Erkenntnisgewinn der Arbeit besteht im qualitativen und quantitativen Nachweis der
gefahrlosen durch kaltes Atmosphärendruckplasma vermittelten Penetrationssteigerung von
Substanzen in die Haut mit speziellem Fokus auf das Stratum corneum.
Die Plasmabehandlung der Haut mit einem Plasmajet lockert abhängig von der
Plasmabehandlungszeit das aus Corneozyten und einer interzellulären Lipidmatrix bestehende
Stratum corneum auf. Die aufgelockerte Struktur des Stratum corneum ermöglicht eine beschleunigte
Penetration verschiedener, nach Plasmabehandlung applizierter Substanzen durch die Haut (Kapitel
4.2.). Die Penetrationssteigerung variiert dabei abhängig von den Stoffeigenschaften der
penetrierenden Substanz (zum Beispiel Molekülgröße und Lipophilie).
Die morphologische Auflockerung des Stratum corneum spiegelt sich im nach der Plasmabehandlung
veränderten Ceramid-Profil wieder. Die veränderten Barriereeigenschaften in den obersten Schichten
des Stratum corneum nach einer einminütigen Plasmabehandlung lassen sich über die Interaktion von
plasma-produzierten reaktiven Spezies mit Lipiden der Haut (insbesondere Triacylglycerolen) und
die dadurch vermittelte Bildung von Triacylglycerol-Oxidationsprodukten erklären (Kapitel 4.4.).
Eine Plasmabehandlung hat im Bereich der in der Dermatologie für den kINPen MED empfohlenen
Anwendungsdauer von 15 s/cm² bis 1 min/cm² keine negativen Auswirkungen auf die Haut (keine
gesteigerte Anzahl an Apoptosen im Stratum basale, Möglichkeit der Regeneration des
aufgelockerten Stratum corneum von basal, (Kapitel 4.3.)). Längere Behandlungszeiten von 2
min/cm² bis 5 min/cm² können jedoch zu Apoptosen in für die Zellregeneration bedeutenden
Schichten führen.
Im Gegensatz zu anderen Methoden zur transdermalen Penetrationssteigerung besteht bei der Plasma-
vermittelten Penetrationssteigerung auf Grund der antibakteriellen Plasmaeigenschaften und der
Penetrationsbeschleunigung von ausschließlich kleinen Stoffen (Größe unter 689 nm) ein geringeres
Risiko der Infektion der behandelten Hautbereiche durch die Einwanderung von Bakterien und
Pilzen. Die Plasmabehandlung stellt demnach eine zukunftsträchtige Möglichkeit zur gefahrlosen
Penetrationssteigerung von Arzneistoffen durch die Hautbarriere dar.
Da die in dieser Arbeit gewonnenen Daten in vitro mit Hilfe eines Schweineohrmodells ermittelt
wurden, ermöglichen sie einen ersten Einblick in die Reaktion der gesunden menschlichen Haut auf
die Plasmabehandlung, lassen sich jedoch nicht eins zu eins auf die in vivo-Situation am menschlichen
Körper übertragen. Zudem sollte bei der Plasmabehandlung in vivo beachtet werden, dass es am
menschlichen Körper große intra- und interindividuelle Unterschiede in der Beschaffenheit der
Hautbarriere gibt, welche zu unterschiedlich starken Effekten der Plasmabehandlung führen könnten.
Ein Vergleich der Penetrationseigenschaften weiterer Stoffe mit unterschiedlichen hydro- und
lipophilen Stoffeigenschaften sowie unterschiedlichen Molekülgrößen vor und nach
Plasmabehandlung wäre für weitere Forschungsarbeiten empfehlenswert. Auf diese Weise könnte
erforscht werden, auf welche Substanzen die Plasmabehandlung der Haut den größten Einfluss hat
und es wären weitere Rückschlüsse auf die Form der aufgelockerten Bindungen, sowie auf eine
eventuelle Interaktion modifizierter Stratum corneum-Bestandteile mit der penetrierenden Substanz
möglich. Gleichzeitig könnten die Versuche mit längeren Penetrationszeiten wiederholt werden, um
zu überprüfen, ob tatsächlich eine Rechtsverschiebung des Peaks der Konzentration der penetrierten
Substanzen (siehe Kapitel 3.4. und Kapitel 3.5.) in tiefere Hautbereiche stattfindet.
Ein direkter Vergleich penetrationssteigernder Methoden (beispielsweise Mikronadeln und
Plasmajet) wäre interessant, um die verschiedenen Systeme auch quantitativ vergleichen zu können
und zu analysieren, ob die Vorteile der plasmavermittelten Penetrationssteigerung gegenüber der
Mikronadelmethode durch die Menge an penetrierter Substanz ausgeglichen werden können.
Neben den Lipiden könnte auch die Modifikation weiterer Stratum-corneum-Bestandteile ursächlich
für die veränderten Barriereeigenschaften der Haut nach Plasmabehandlung sein. Interessant wäre
deshalb auch die Untersuchung der Stratum-corneum-Peptide und -Proteine vor und nach
Plasmabehandlung.
Um die Reaktion der Haut in vivo auf die Plasmabehandlung besser vorhersagen zu können und damit
die im Rahmen dieser Arbeit erlangten Erkenntnisse in die klinische Praxis übertragen zu können,
sind weitere Studien nötig. Diese könnten die in vitro-Experimente am Schweineohr beispielsweise
auf ein in vivo-Mäusehautmodell übertragen. An einem frischen Mäusehautmodell wäre auch die
Untersuchung längerer Penetrationszeiten sowie die Geschwindigkeit der Hautregeneration und dem
damit Verbundenen Wiederaufbau der Hautbarriere nach Plasmabehandlung möglich.
Nach einer Verifizierung der Ergebnisse in vivo könnten die im Rahmen dieses Projekts gewonnenen
Erkenntnisse in Zukunft auf den klinischen Alltag übertragen werden. Für Langzeittherapien bei
speziellen Patientengruppen mit Problemen bei der oralen Medikamentenaufnahme (beispielsweise
in Form von Resorptionsstörungen im Magen-Darm-Trakt) oder bei einem starken First-Pass-Effekt
des Medikaments in der Leber ist die transdermale Medikamentenapplikation eine
Ausweichmöglichkeit, welche durch eine vorherige Plasmabehandlung der Haut noch verbessert
werden würde.
Im Rahmen des bereits etablierten medizinischen Anwendungsfelds von kaltem
Atmosphärendruckplasma bei der Behandlung chronischer Wunden könnte eine Plasmabehandlung
der Wundränder und angrenzender gesunder Hautbereiche die Penetration von nach der Behandlung
applizierten wundheilungsfördernden Cremes und Gels im betroffenen Gebiet beschleunigen und so
die Heilungsaussichten noch weiter verbessern.
Von 3000 Untersuchungshandschuhen, die von Pflegekräften auf einer Intensiv- und einer Weaningstation getragen wurden, waren 308 perforiert (10,3 %). Insgesamt wurden 389 einzelne Perforationen in den defekten Hand- schuhen gefunden. Latexhandschuhe (13,9 %) wiesen höhere Perforations- raten auf als Nitrilhandschuhe (6,6 %). Nur 5,2 % der Perforationen wurden durch den jeweiligen Träger bemerkt. Lange Tragedauer, Desinfizieren der Handschuhe, schlechter Sitz der Handschuhe, Waschen des Patienten sowie Desinfizieren von Flächen begünstigten das Auftreten von Perforationen. Keinen Einfluss auf die Perforationsrate hatten dagegen der jeweilige Träger und die Größe der Handschuhe. Auch für die verwendeten Waschmittel und Cremes wurde kein Einfluss auf das Perforationsrisiko festgestellt. Die Tragedauer hatte den wichtigsten Einfluss auf die Perforationsrate. Für die hier untersuchten Arbeitsbereiche könnte eine Beschränkung der Tragedauer auf 15 min einen Kompromiss zwischen Sicherheit und Realisierbarkeit im klinischen Alltag darstellen. Für eine generelle Empfehlung zur Maximaltragedauer von Untersuchungshandschuhen reichen die ermittelten Daten nicht aus, da zu viele Faktoren die Perforationsrate beeinflussen. Gesundheitseinrichtungen sollten, basierend auf individuellen Risiken, eigene Empfehlungen formulieren. Die niedrigere Perforationsrate bei Nitrilhandschuhen spricht dafür, dass diese vermehrt getragen werden sollten. Zumindest im Umgang mit hochinfektiösen Patienten könnte der Gebrauch auf Nitrilhandschuhe beschränkt werden. Alternativ sollte für Latexhandschuhe double gloving praktiziert werden. Insgesamt sollten medizinische Einrichtungen sorgfältig auf die Qualität ihrer Handschuhe achten. Das wiederholte Auftragen von Desinfektionsmitteln auf die Handschuhe scheint das Auftreten von Perforationen zu begünstigen. Generell sollte davon abgeraten werden, Untersuchungshandschuhe zu desinfizieren. Aus Gründen der Praktikabilität ist es aber in bestimmten Situationen vertretbar, bis zu drei Desinfektionen der Handschuhe durchzuführen. Weiterhin sollte stets auf den passgenauen Sitz der Handschuhe geachtet werden. Überdies ist es wichtig, das Pflegepersonal über die Gefahr der Infektionsverbreitung durch Erregertranslokation durch Mikroperforationen in Handschuhen aufzuklären und dadurch die Compliance gegenüber Hygienevorschriften zu fördern. Dazu sollte eine konkrete Einweisung zum Gebrauch von Untersuchungshandschuhen stattfinden.
Hintergrund: Für die Einschätzung der Notwendigkeit einzelner Hygienemaßnahmen im Vergleich zwischen Hygienepersonal und chirurgisch tätigen Ärzten ist in der Literatur kein Messinstrument beschrieben. Der Vergleich dieser beiden Gruppen erschien von Interesse, da sich daraus Ansätze ergeben, was in der Aus- und Weiterbildung der Berücksichtigung bedarf. Methode: Es wurde nach einer Möglichkeit gesucht, bei der möglichst viele Fachkräfte beider Berufsgruppen gleichzeitig anzutreffen sind. Hierfür erschienen vor allem Kongresse der jeweiligen Berufsgruppe geeignet zu sein. Der theoriegeleitete selbstentwickelte Fragebogen wurde daraufhin auf dem 10. Internationalen Kongress der Deutschen Gesellschaft für Krankenhaushygiene und auf dem 127. Kongress der Deutschen Gesellschaft für Chirurgie verteilt. Außerdem wurden 100 Fragebogen an die Fachabteilungen Allgemeinchirurgie, Unfallchirurgie und Orthopädie von 8 Kliniken in Deutschland verteilt. Ergebnisse: Von insgesamt 1200 Fragebögen wurden 109 Fragebögen korrekt und vollständig ausgefüllt zurückgegeben und konnten in die Arbeit einfließen. Das entspricht einer Ausschöpfungsquote von 9.4 %. Mithilfe der Datenanalyse konnte gezeigt werden, dass Hygienefachkräfte im Durchschnitt die Hygienemaßnahmen als wichtiger einstufen als das von Ärzten vorgenommen wird. Es wiesen allerdings nicht alle 30 Items des Fragebogens signifikante Unterschiede zwischen den beiden untersuchten Gruppen auf. Die Dienstjahre hatten nur bei den beiden Items ‚atraumatisches Arbeiten‘ und ‚Narkoseführung‘ einen signifikanten Einfluss auf die Bewertung. Im Vergleich der beiden Berufsgruppen zueinander stellte sich heraus, dass es signifikante Unterschiede in der Einschätzung der Bewertung einzelner Hygienemaßnahmen zwischen Hygienefachkräften und allen Ärzten, unabhängig ob Chefarzt, Oberarzt, Facharzt oder Assistenzarzt, gibt. Es zeigte sich, dass Hygienefachkräfte nicht alle abgefragten Items für wichtiger einstuften als Ärzte dies taten. Lediglich 11 der insgesamt 30 Items wurden von Hygienefachkräften als wichtiger eingestuft. Schlussfolgerung: In der Arbeit wurde ein Messinstrument erprobt, das eine Basis für weitere Untersuchungen auf dem Gebiet der Hygiene sein könnte. Allerdings sollte es noch optimiert werden und eventuell bis dahin neu auftretende Problematiken sowie Themen im Bereich der Hygiene berücksichtigen. Es konnte in dieser Arbeit die Soll-Ist-Diskrepanz aufgezeigt werden, woraus sich Implikationen sowohl für die Forschung als auch für die tägliche Arbeit in Kliniken und Praxen am Patienten ableiten lassen. Insgesamt lässt sich festhalten, dass Hygienemaßnahmen ständig an Bedeutung gewinnen. So ist neben der ethischen und sozialen Komponente vor allem auch die politische und ökonomische Relevanz nicht zu unterschätzen. Kosteneinsparungen und Personalmangel führen dabei täglich zu neuen Herausforderungen.
Angesichts der zu beachtenden Risiken bei der Anwendung von Chlorhexidin ist die Erprobung weiterer Mundhöhlenantiseptika als notwendig anzusehen. Chlorhexidin wirkt u. a. mutagen, indiziert für experimentell nach 14 d reversible prämaligne Alterationen. In der vorliegenden Studie wurde eine 0,12%ige Polihexamid (Lavasept®)- Mundspüllösung mit einem Placebo, einer 0,12%igen Chlorhexidin-Mundspüllösung sowie mit der kommerziellen Mundspüllung Listerine® verglichen. Der in vivo antibakterielle Effekt wurde durch Aufnahme der Bakterienmenge von der Zahnoberfläche (Zahn 36) und der Mukosa 4 h nach der ersten Mundspülung und 5 d später, d.h. 12 h nach der letzten Mundspülung. Für die Untersuchung wurden 16 freiwillige gesunde Versuchspersonen rekrutiert. Die ermittelten Daten wurden anhand von ANOVA mit Bonferroni-Korrekturen für multiple Vergleiche analysiert (Signifikanzniveau a = 0,05). Lavasept war in der Plaquehemmung signifikant wirksamer als Placebo. Es gab keinen signifikanten Unterschied zu Chlorhexidin und Listerine. In der Bakterienreduktion auf der Mukosa war Lavasept nach 4 h und 5 d signifikant wirksamer als Listerine und Placebo. Chlorhidin war hier allen 3 anderen Mundspülungen überlegen. Auf der Zahnoberfläche zeigte Lavasept in der Kurzzeitwirkung tendenziell die antiseptische Wirksamkeit von Chlorhexidin. Lavasept war nach 4 h und 5 d auf der Zahnoberfläche signifikant wirksamer in der Bakterienreduktion als Listerine und Placebo. Übereinstimmend mit vorherigen Studien (Rosin et al. 2001) konnte gezeigt werden, dass Lavasept die Bakterienrekolonisation behindert und die orale Bakterienmenge reduziert. Die vorliegenden Ergebnisse lassen es aussichtsreich erscheinen, den Einfluss von Polihexamid (Lavasept®) als Mundspülung in der Prävention plaque-assoziierter Erkrankungen auch bei bereits etablierter Plaque zu untersuchen.
Zusammenfassung
Zielsetzung: Eine Analyse des Hygienestatus im Rettungsdienst in Deutschland ergab eine Reihe von Defiziten (Groß 2010). Die sich daraus ergebenden Schlussfolgerungen wurden zunächst publiziert (Groß et al. 2010, Kramer et al. 2013), fanden 2014 Eingang in die Leitlinie der AWMF zu „Hygienemaßnahmen beim Patiententransport“ und wurden 2019 bei der Aktualisierung der Leitlinie berücksichtigt, wobei die ursprünglichen Schlussfolgerungen der o.g. Arbeit nicht an Gültigkeit eingebüßt haben. Um die Situation in einem ganzen Land zu analysieren, wurde Island als kleines Land ausgewählt.
Methode: Im Juli 2011 wurde eine Islandweite flächendeckende Umfrage in Form eines Fragebogens durchgeführt und an alle Rettungswachen verteilt, die am Krankentransport und Rettungsdienst beteiligt sind und 24-Stunden Bereitschaftsdienst haben. Ein Fragebogen mit 43 Fragen richtete sich an die Wachleiter*innen, ein separater Fragebogen mit 35 Fragen an das Personal.
Ergebnisse: 33 Fragebögen der Wachleiter*innen und 94 Fragebögen des Personals wurden vollständig beantwortet und ausgewertet.
Es kann auf beinahe allen befragten Themengebieten ein Defizit in der Gesetzeslage bzw. in Bezug auf Vorschriften und Leitlinien festgestellt werden. Das hat einen mangelhaften Wissensstand des Personals des Rettungsdiensts und Krankentransports zur Folge. Die Personalhygiene (Hände, Kleidung, Impfungen), der Fahrzeuge, Schutzmaßnahmen gegen multiresistente Erreger, die Qualitätssicherung und die Schulung bedürfen einer durchgreifenden Verbesserung. Gerade wenn vor allem in ländlichen Regionen Islands nur wenige Krankentransporte durchgeführt werden, entbindet das nicht von der Einhaltung der Basishygiene.
Schlussfolgerung: In der rasch globalisiert wachsenden Welt muss eine einheitliche landesübergreifende Regelung hygienischer Verfahrensweisen zum Schutz des Personals und der Patienten*innen im Rettungsdienst und Krankentransport in Island ausgearbeitet und unterrichtet werden.
Da es nur wenig offizielle und v.a. länderübergreifende Empfehlungen bzw. Verfahrensanweisungen gibt, wird zur Verbesserung ein Maßnahmenkatalog vorgeschlagen, der der Nationalen Gesundheitsbehörde übergeben wurde.
Zielsetzung: Die antimikrobielle Wirksamkeit von kaltem Atmosphärendruckplasma(CAP), auch als gewebeverträgliches Plasma (TTP) bezeichnet,könnte eine aussichtsreiche Option zur Eradikation von Methicillinempfindlichen ebenso wie von Methicillin-resistenten Staphylococcus aureus-Stämmen sein, die oft chronische Wunden kolonisieren. Bisher wurde der Einfluss von CAP auf die Antibiotikaempfindlichkeit von S. aureus kaum untersucht. Da eine Veränderung der Antibiotikaempfindlichkeit für die Wundbehandlung relevant sein könnte, sollte der Einfluss von CAP auf die Empfindlichkeit verschiedener S. aureus-Stämme gegen unterschiedliche Antibiotika untersucht werden.
Methode: Im Agardiffusionstest wurden Antibiotikatestplättchen mit Cefuroxim, Gentamicin, Oxacillin, Vancomycin, Ciprofloxacin, Co-Trimoxazol, Clindamycin und Erythromycin eingesetzt. Die Teststämme wurden auf Agar ausplattiert und mit CAP exponiert, bevor die Testplättchen aufgelegt wurden. Nach 24 h Bebrütung wurden die Inhibitionszonen gemessen und statistisch auf Unterschiede geprüft.
Ergebnisse: In den meisten Fällen war die Einfluss von CAP auf die Antibiotikaempfindlichkeit zu vernachlässigen. Für zwei Stämme wurde die Empfindlichkeit gegenüber β-Lactam-Antibiotika signifikant herabgesetzt.
Schlussfolgerung: Da CAP die Antibiotikaempfindlichkeit beeinflussen kann, sollten vor beabsichtigter kombinierter lokaler CAP-Behandlung und gleichzeitiger systemischer Antibiotikagabe Interaktionen in vitro untersucht werden, um unerwünschte Kombinationseffekte auszuschließen.
Der antiseptischen, antiphlogistischen und kariesprotektiven Wirkung von Mundspüllösungen wird in der heutigen Zeit zunehmende Bedeutung beigemessen, da eine mechanische Plaquereduktion nicht ausreichend ist. Zahlreiche Studien konnten bisher eine prophylaktische und therapeutische Wirkung nachweisen. Dagegen gibt es keine systematischen Untersuchungen zur Verträglichkeit dieser Präparate. Da diese häufig jahrelang angewendet werden, wird die Kenntnis der Gewebeverträglichkeit für wichtig erachtet. In der vorliegenden Studie wurde daher die Gewebeverträglichkeit folgender häufig eingesetzter Mundspülungen untersucht: Chlorhexamed Fluid 0,1%, Listerine,Colgate total und Meridol. Damit sollte zugleich überprüft werden, ob der Explantattest als Semi- in- vivo- Verfahren geeignet ist, die Gewebetoxizität von Mundspüllösungen differenziert zuermitteln. Mit Hilfe des Explantattests wurden Zellwachstumsraten an frisch entnommenen Gewebeexplantaten von 21-24 Explantaten je Versuchsreihe untersucht. Untersucht wurde die Zellschädigungsrate der verwendeten Mundspüllösungen in der Anwendungskonzentration sowie in Verdünnungen von 10%, 1% und 0,1% mit einer Einwirkzeit von 1 min, 10 min und 30 min. Im Intervergleich der unverdünnten Lösungen unter realistischen Einwirkzeiten weisen Chlorhexamed und Colgate signifikant höhere Zellschädigungen auf als Meridol. Die Wirkung der Mundspüllösungen Chlorhexamed und Listerine ist zeitabhängig. Bei längeren Einwirkzeiten zeigt sich eine deutlich höhere Gewebetoxizität. Colgate ist in seiner Wirkung sowohl zeit- als auch konzentrationsabhängig. Die Anwendungskonzentration weist gegenüber der Verdünnung eine signifikant höhere Toxizität auf. Als einzige Mundspüllösung weist Meridol neben der Zeit- und Konzentrationsabhängigkeit auch eine Abhängigkeit von der Wechselwirkung Zeit/Konzentration auf. Diese Mundspüllösung erscheint besonders geeignet, da sie bei hoher Substantivität keine späten Zellschäden verursacht. Der Explantationstest hat sich als geeignetes sensitives Screeningmodell zur quantifizierbaren Beurteilung der lokalen Gewebeverträglichkeit erwiesen.
Im 19. Jahrhundert nahmen die Therapiemöglichkeiten der Zahnärzte zu. Der technische Fortschritt ermöglichte eine verstärkte Zuwendung zur restaurativen, konservierenden Zahnheilkunde. Gleichzeitig wuchsen in Deutschland die Anforderungen an die Ausbildung der Zahnärzte. Obwohl es in Mecklenburg-Strelitz keine zahnärztliche Ausbildung gab, waren die gesetzlichen Anforderungen für eine Zulassung zur zahnärztlichen Tätigkeit höher als in anderen deutschen Staaten - bis zur Einführung der Gewerbeordnung 1869. Etwa ab Mitte des 19. Jahrhunderts erhöhte sich auch der wissenschaftliche Erkenntnisstand in der Bakteriologie und der Hygiene. Das schlug sich zunächst in der ärztlichen, später auch in der zahnärztlichen Tätigkeit nieder. Allerdings verzögerte die Gewerbefreiheit, die eine Ausübung der Zahnbehandlung durch medizinische Laien erlaubte, die verbindliche Umsetzung dieser Erkenntnisse um mehrere Jahrzehnte. Auf der einen Seite kam es zu einer immer vollkommeneren Ausbildung in der Zahnmedizin an Universitäten, auf der anderen Seite entwickelte sich die handwerklich und zahntechnisch ausgerichtete Ausbildung der Dentisten. Erst nach etwa 80 Jahren wurde ein einheitlicher Berufsstand der mit der zahnmedizinischen Behandlung befassten Personen erreicht. Die Gesetzgebung zum Schutz vor Seuchen war zu diesem Zeitpunkt auf dem Gebiet der allgemeinen Medizin schon relativ umfassend. Eine verbindliche Richtlinie oder Verordnung, die den Besonderheiten der zahnärztlichen Behandlung Rechnung trug, wurde nicht erlassen, obgleich die Gesetzgebung in beiden deutschen Staaten zum Schutz der Allgemeinheit Regelungsbedarf für die Gesundheitseinrichtungen insgesamt sah. So kam es, dass Richtlinien, die Erkenntnisse und Fortschritte auf dem Gebiet der Hygiene für die zahnmedizinischen Einrichtungen einführten, erst wesentlich später erlassen wurden. Zu einem entscheidenden Zeitpunkt ihrer Entwicklung war die Zahnmedizin durch den Gesetzgeber von der Entwicklung der Medizin und der Hygiene abgekoppelt worden. Es dauerte einige Jahrzehnte, bis die Hygiene den Stellenwert in der Zahnmedizin einnehmen konnte, den sie in der allgemeinen Medizin schon lange hatte. Dieser Rückstand wird nun durch eine ständige Überarbeitung der Hygienerichtlinien und die Anpassung an den medizinisch-technischen Fortschritt aufgeholt.
Hintergrund: Wie in vielen anderen Bereichen der Medizin kann ein Methicillin-resistenter Staphylococcus aureus (MRSA) auch zahnmedizinisches Personal sowie ihre Patient*innen besiedeln. Studien zur Prävalenz von MRSA und Methicillin-sensiblem S. aureus (MSSA) bei dieser Berufsgruppe sowie zum Trageverhalten bei persönlicher Schutzausrüstung (PSA) sind jedoch rar.
Ziel: Es wurde eine Beobachtungsstudie (StaphDent Studie) durchgeführt, um die Prävalenz von MRSA und MSSA bei Zahnärzt*innen und zahnärztlichem Personal in der Region Mecklenburg-Vorpommern zu bestimmen. Des Weiteren sollte die Compliance zum Einhalten der Hygienemaßnahmen anhand des Trageverhaltens von PSA ausgewertet werden, um daraus mögliche Rückschlüsse in Bezug auf die Prävalenz von MRSA und MSSA ableiten zu können.
Methoden: Von Zahnärzt*innen (n= 149), zahnärztlichem Personal (n= 297) sowie von weiteren Praxisangestellten wurden zum größten Teil im Selbsttestverfahren Nasenabstriche entnommen. Es erfolgte die Auswertung im Fachbereich Mikrobiologie. Die klonale Verwandtschaft der MSSA-Isolate wurde durch spa-Typisierung und in einigen Fällen durch Ganzgenomsequenzierung charakterisiert. Die Verwendung von PSA wurde anhand eines Fragebogens ermittelt.
Ergebnisse: Während 23,7% (115/485) der Teilnehmenden mit MSSA kolonisiert waren, konnte MRSA in keiner der Proben nachgewiesen werden. Die MSSA-Prävalenz steht in keinem statistischen Zusammenhang mit der Praxisgröße, dem Geschlecht, dem Alter oder der Dauer der Beschäftigung. Die identifizierten 61 spa-Typen ließen sich 17 klonalen Komplexen und vier Sequenztypen zuordnen. Die meisten spa-Typen (n= 51) wurden nur einmal nachgewiesen. In 10 Zahnarztpraxen trat ein spa-Typ zweimal auf. Die Ganzgenomsequenzierung bestätigt eine enge klonale Beziehung für 4/10 dieser Isolatpaare. PSA wurde von den meisten Zahnärzt*innen und ihren Mitarbeitern und Mitarbeiterinnen regelmäßig verwendet.
Schlussfolgerung: Der fehlende Nachweis von MRSA spiegelt die geringere MRSA-Prävalenz in dieser Berufsgruppe wider. Das zum größten Teil konsequente Tragen der PSA und die damit verbundene hohe Compliance bei der Einhaltung der Hygienemaßnahmen scheinen für dieses Ergebnis ursächlich zu sein.
Murphy und Mitarbeiter (1998) postulierten, dass Estrogene die GABA-Synthese in Interneuronen supprimieren und spekulierten, dass durch diese verminderte GABA-Synthese eine Disinhibition des CA1-Neuronen-Netzwerkes erfolgt. Das Ergebnis einer solchen erhöhten neuronalen Exzitation ist eine Vermehrung von Dorn-Synapsen. Demzufolge wäre Estradiol als prokonvulsiv anzusehen. Dieser Annahme wollten wir mit unseren Experimenten nachgehen. Dazu haben wir zunächst die GAD-65-Expression nach Estradiol-Applikation untersucht. Wir fanden im Gegensatz zu Murphy nach Gabe von Estradiol, keine Herunterregulation der GABA-Synthese und konnten somit eine prokonvulsive Wirkung von Estradiol nicht bestätigen. In einem weiteren Experiment haben wir in hippocampalen Slice-Kulturen den GABAA-Rezeptor mit Bicucullin blockiert und damit neuronale Übererregung erzeugt. Die Bicucullin-Behandlung der Kulturen führte erwartungsgemäß zu einem signifikanten Dorn-Synapsen-Verlust, der gleichzeitig aber auch mit einer signifikanten Verminderung der Estradiol-Synthese einherging. Durch die Zugabe des Aromatase-Hemmers Letrozol zu den Kulturen ließen sich diese Befunde ebenfalls erzielen. In einem Rescue-Experiment konnten wir mit der Gabe von Estradiol, den durch Bicucullin oder Letrozol induzierten Dorn-Synapsen-Verlust wieder aufheben. Die neuroprotektive Wirkung von 17-β-Estradiol im Rahmen der Epilepsie ist vermutlich auf die Wiederaufhebung der verminderten Estradiol-Synthese und in der Folge verminderten GABA-Synthese zurückzuführen.
Inhaltsverzeichnis 1. EINLEITUNG UND PROBLEMSTELLUNG 1.1. EINLEITUNG 1.1.1. Peritonitisformen / Ätiologie 1.2. PROBLEMSTELLUNG 1.3. NEUE ENTWICKLUNGEN ZUR BEEINFLUSSUNG DER CHRONISCHEN ABSZEDIERENDEN PERITONITIS IM TIERMODELL 1.4. ANMERKUNGEN ZUR ANTISEPTIK 1.4.1. Antiseptik - Begriff 1.4.3. Taurolidin 1.4.4. Lokalantibiotika 1.4.5. Antimikrobielle Chemotherapeutika 2. EIGENE UNTERSUCHUNGEN UND ERGEBNISSE 2.1. MATERIAL UND METHODEN 2.1.1. Versuchstierspezies 2.1.2. Tierhaltung 2.1.3. Genehmigung der Studie 2.1.4. Geplantes Peritonitismodell 2.1.5. Histologische Auswertung 2.1.6. Versuchsgruppen bildung 2.2. ERGEBNISSE 2.2.1. Makroskopische Ergebnisse Dosisoptimierungsversuche 2.2.2. Histologische Ergebnisse Dosisoptimierungsversuche 3. DISKUSSION 3.1. ANMERKUNGEN ZUM TIERMODELL 3.2. DISKUSSION DER VERSUCHSERGEBNISSE 4. ZUSAMMENFASSUNG 5. LITERATURVERZEICHNIS
Perspektiven und Risiken des Einsatzes eines körperwarmen elektrischen Plasmas in der Medizin
(2011)
Durch die vorgestellten Studien konnte gezeigt werden, dass Temperatureffekte und UV-Strahlung, die bei der Plasma-Gewebe-Wechselwirkung entstehen, keine Gefährdung für den Menschen darstellen. Die hohe antiseptische Wirkung des Plasmas ist offensichtlich auf die Bildung großer Mengen freier Radikale speziell an der Hautoberfläche, aber auch in den Haarfollikeln zurückzuführen. Die Tatsache, dass das Plasma in die Haarfollikel eindringen kann, stellt einen deutlichen Vorteil gegenüber der Anwendung flüssiger Antiseptika dar. Um jedoch eine effektive Antiseptik der Hautoberfläche zu erreichen, ist es notwendig, Plasma-Jet-Systeme mit einem Durchmesser des Plasmastrahls von ≥ 5 mm zu entwickeln. In diesem Fall ist zu erwarten, dass die Plasmabehandlung mindestens ähnliche Ergebnisse wie die Behandlung mit Octenisept® aufweist. Es ist wahrscheinlich, dass Temperatureffekte, UV-Strahlung und Radikalbildung Synergieeffekte in der menschlichen Haut bewirken, die die antiseptische Wirkung der freien Radikale als Einzelkomponente übersteigen. Damit kommt der Plasmatechnologie in Zukunft eine besondere Bedeutung bei der Wundbehandlung zu. Darüber hinaus konnte gezeigt werden, dass die Plasmabehandlung die Penetration von Partikeln und Agentien stimuliert. Damit eröffnen sich neue Möglichkeiten für eine Plasmaanwendung im Bereich der Wirkstoffzufuhr in und durch die Haut. Inwieweit diese Wirkstoffe vor oder nach der Plasmabehandlung auf die Hautoberfläche aufgetragen werden müssen, ist Zielsetzung weiterer Untersuchungen. Generell kann festgestellt werden, dass es sich bei TTP um eine neue Technologie handelt, die ein hohes Potenzial für den klinischen Einsatz aufweist. Es ist zu erwarten, dass die Anwendung von TTP im medizinischen und biotechnischen Bereich in den nächsten Jahren stark zunehmen wird. Mit der vorliegenden Arbeit wurde eine wichtige Grundlage zur Risikobewertung der Anwendung von TTP in der Medizin geschaffen und ein Beitrag zur Klärung des Wirkungsmechanismus von Plasmen im Gewebe geleistet. Darüber hinaus konnte ein neues Anwendungsgebiet der Plasmabehandlung in Form der Stimulation der Penetration von topisch applizierten Substanzen aufgezeigt werden.
Wound healing disorders frequently occur due to biofilm formation on wound surfaces requiring conscientious wound hygiene. Often, the application of conventional liquid antiseptics is not sufficient and sustainable as (1) the borders and the surrounding of chronic wounds frequently consist of sclerotic skin, impeding an effectual penetration of these products, and (2) the hair follicles representing the reservoir for bacterial recolonization of skin surfaces are not affected. Recently, it has been reported that tissue-tolerable plasma (TTP), which is used at a temperature range between 35 and 45°C, likewise has disinfecting properties. In the present study, the effectivity of TTP and a standard liquid antiseptic was compared in vitro on porcine skin. The results revealed that TTP was able to reduce the bacterial load by 94%, although the application of the liquid antiseptic remained superior as it reduced the bacteria by almost 99%. For in vivo application, however, TTP offers several advantages. On the one hand, TTP enables the treatment of sclerotic skin as well, and on the other hand, a sustainable disinfection can be realized as, obviously, also the follicular reservoir is affected by TTP.
Colonization and infection of wounds represent a major reason for the impairment of tissue repair. Recently, it has been reported that tissue-tolerable plasma (TTP) is highly efficient in the reduction of the bacterial load of the skin. In the present study, the antiseptic efficacy of TTP was compared to that of octenidine hydrochloride with 2-phenoxyethanol. Both antiseptic methods proved to be highly efficient. Cutaneous treatment of the skin with octenidine hydrochloride and 2-phenoxyethanol leads to a 99% elimination of the bacteria, and 74% elimination is achieved by TTP treatment. Technical challenges with an early prototype TTP device could be held responsible for the slightly reduced antiseptic properties of TTP, compared to a standard antiseptic solution, since the manual treatment of the skin surface with a small beam of the TTP device might have led to an incomplete coverage of the treated area.
Es gibt für den Rettungsdienst keine einheitlichen Regelungen bezüglich hygienischer Voraussetzungen und Organisation des Infektionsschutzes. Aus diesem Grund sollte in allen Rettungswachen Vorpommerns einschließlich der Patientenübergabe an das Krankenhaus der Hygienestandard analysiert werden, um auf dieser Grundlage Empfehlungen zu erarbeiten. Mit einem standardisierten Fragebogen (119 Fragen) wurden 42 Rettungswachen analysiert. Ergänzend wurde als Stichprobe eine hygienisch- mikrobiologische Überprüfung zur Ermittlung potentieller Infektionsquellen im RTW an folgenden Untersuchungsstellen durchgeführt: Handwaschbecken, Sauerstoffinsufflation, manuelles bzw automatisches Beatmen, Blutdruckmessen, Beatmungskoffer, Bedienknopf des Beatmungsgerätes, Luftkammerschiene, Vakuummatratze, Schublade für Sterilgut und Handschuhe in Jackentasche. Die Fragebögen wurden von allen Rettungswachen beantwortet. Unabhängig von der Trägerschaft und vom Leistungserbringer sind die Voraussetzungen für ein hygienisches Qualitätsmanagement im wesentlichen gegeben. Das betrifft den baulichen Zustand und die Ausstattung der Rettungswachen, die Lagerung von Medikamenten und Verbandmaterialien, die adäquate Instrumentenaufbereitung, die korrekte Hände- und Wäschehygiene (Vorhandensein von Desinfektionsspendern im RTW), die Existenz von stich- und bruchfesten Sammelboxen im RTW sowie die Verwendung geschlossener Blutentnahmesysteme. In Einzelfällen sind aber gravierende Mängel festgestellt worden. Hier sind folgende Aspekte zu nennen: mangelndes Problembewußtsein, inkomplette Immunisierung (Ausnahme Hepatitis-A und B-Impfung beim Personal), kein genereller Einsatz von Sterilfiltern für Beatmungsgeräte, unzureichendes Desinfektionsregime, kritischer Umgang mit der Sauerstoffbefeuchtung, kein generelles Tragen von Schutzhandschuhen, unvollständige Ausstattung mit Mund-Nasen-Schutz, Tb-Masken und Schutzbrillen, keine Aktualisierung von Hygieneplänen, unklare Verantwortlichkeiten (Qualitätssicherung, Fehlen benannter Hygienebeauftragte), mangelnde Entsorgungsrichtlinien und Wasserbehälterhygiene. Zu erwähnen sind weiterhin die ungenaue Information der Rettungsteams über den Notfallpatienten und die noch zu verbessernde Weiterbetreuung von Notfallpatienten in der Klinik. Bei den in den Rettungswagen nachgewiesenen Keimen handelte es sich überwiegend um Hautkeime (koagulasenegative Staphylokokken, S. epidermidis) Es wurden aber auch grampositive Stäbchenbakterien, P. aeruginosa, Enterokokken und Dermatophyten isoliert. Das zeigt, daß die Händehygiene und die Desinfektion und Reinigung im RTW intensiviert werden müssen. Das Wasser aus dem Vorratsbehälter des Handwaschbeckens stellte ein nicht tolerierbares Erregerreservoir dar.
Gegenstand der vorliegenden Untersuchung war die Frage, ob durch die Verwendung synthetischer Matratzenganzbezüge die Besiedlung fabrikneuer Matratzen mit Schimmelpilzen, Bakterien und Hausstaubmilben im Vergleich zu herkömmlichen Baumwollbezügen reduziert werden kann. Es wurden 84 freiwillige Personen auf 2 Gruppen verteilt. Gruppe A (N=43) erhielt Bezüge aus Baumwolle, Gruppe B (N=41) Bezüge aus einer Polyestermicrofaser mit Polyurethanbeschichtung. Die Hausstaubmilbenantigenkonzentration zeigte nach 6 Monaten Studiendauer eine signifikant geringere Zunahme in Gruppe B. Sowohl hinsichtlich der Bakterien als auch der Schimmelpilze kam es in Gruppe A bereits nach 3 Monaten Studiendauer zu einer signifikant höheren Besiedlung als in Gruppe B. Aufgrund dieser Ergebnisse kann sowohl Hausstaubmilbenallergikern als auch Schimmelpilzallergikern die Verwendung der synthetischen Matratzenganzbezüge empfohlen werden.
Derzeit wird bei der hygienischen Händedesinfektion eine Einreibedauer von 30 s empfohlen, welche in der Praxis oft nicht eingehalten werden kann. Zwar sorgt der alkoholische Anteil des Desinfektionsmittels allein schon für eine antimikrobielle Wirkung, dennoch spielt auch die Verteilung des Desinfektionsmittels und damit die Benetzung der Hautoberfläche eine wichtige Rolle um ein optimales Ergebnis zu erzielen. Die Benetzung kann durch eine Verlängerung der Einwirkzeit gesteigert und durch die Zusammensetzung des Desinfektionsmittels beeinflusst werden. Ziel der vorliegenden Arbeit war es herauszufinden, ob bei einer Anwendungsdauer der hygienischen Händedesinfektion von 15 s ein ebenso hoher Benetzungsgrad wie nach 30 s Einreibezeit erreichbar ist, und welchen Einfluss das Training auf den Benetzungsgrad hat. Dazu wurden 20 Probanden ausgewählt, die in einer randomisierten, gekreuzten Laborstudie an insgesamt vier Versuchstagen die hygienische Händedesinfektion mit einem UV-reaktivem Händedesinfektionsmittel durchführten. An den ersten beiden Versuchstagen galten die Probanden als untrainiert und hatten entweder 15 oder 30 s Zeit für die Durchführung der Händedesinfektion. An den letzten beiden Versuchstagen wurde das Standardeinreibeverfahren trainiert und ebenfalls für 15 bzw. 30 s angewendet. Die Vorder- und Rückseiten der benetzten Hände wurden unter UV-Licht fotografiert und die Fotos mit Hilfe einer Software ausgewertet, die benetzte von unbenetzten Arealen unterschied. Die Ergebnisse erlauben folgende Schlussfolgerungen. Die Einreibezeit allein hat keinen Einfluss auf den Benetzungsgrad der Hand. Nach 30 s wurden durchschnittlich 86,4 % der Handoberfläche benetzt, nach 15 s waren es 82,0 %. Die Differenz von 4,4 % war statistisch nicht signifikant. Auch bei einer verkürzten Anwendung der hygienischen Händedesinfektion ist demnach ein ähnlich hoher Benetzungsgrad zu erreichen wie nach den empfohlenen 30 s. Es gibt keinen Unterschied hinsichtlich der benetzten Fläche, wenn man sie lediglich in Hinblick auf die Einreibedauer vergleicht. Jedoch gibt es einen unterschied in der Benetzung zwischen trainierten und untrainierten Probanden unabhängig davon ob sie 15 oder 30s Zeit zur Händedesinfektion hatten (p<0,05). Trainierte Probanden erreichten einen Benetzungsgrad von 88,8 %, der damit um 9,2 % höher war als ohne Training. Trainierte Probanden, die 15 s Zeit hatten, die Schritte des Standardeinreibeverfahrens durchzuführen, benetzen eine größere Fläche als Probanden, die zwar 30 s Zeit hatten, aber untrainiert waren. Das verdeutlicht, welchen Stellenwert die Schulung des medizinischen Personals in der Vermeidung nosokomialer Infektionen hat. Ein besonderes Augenmerk bei der Durchführung der Einreibeschritte sollte auf die Benetzung des Handrückens, vor allem der rechten Seite, gelegt werden, da diese auch nach entsprechendem Training nur zu 83,1 % benetzt wurde. Als Fazit ergibt sich, dass es möglich ist, auch nach einer Einreibedauer von 15 s die Hand zufriedenstellend zu benetzen, allerdings unter der Voraussetzung, dass der Anwender trainiert ist. Das unterstreicht die Wichtigkeit konsequenter Schulungen und regelmäßiger Supervisionen zur Durchführung der Händedesinfektion. Eine Methode ist dabei die Verwendung von fluoreszierendem Desinfektionsmittel und die Kontrolle der Hand unter UV-Licht. Die Ergebnisse stellen quasi eine Legitimation der derzeitigen Praxis dar, verweisen aber zugleich auf die Wichtigkeit des Trainings der Händedesinfektion. Da man von gleicher bakteriozider Wirksamkeit des Desinfektionsmittels nach 15 und 30 s ausgeht, bleibt zu diskutieren, ob generell ein Herabsetzen der Einreibedauer für trainierte Anwender möglich ist.
Die Therapie des Melanoms sowie die Erforschung neuer Behandlungsmöglichkeiten stehen im Fokus zahlreicher Forschungsgruppen. Um der Komplexität dieser Erkrankung gerecht zu werden, müssen möglichst genaue Modelle gefunden werden. Tumor-Sphäroide als dreidimensionale Tumorzellkulturen schließen dabei teilweise die Lücke zwischen den herkömmlichen zweidimensionalen Zellmonolayern und den Tiermodellen. Hierdurch lassen sich die zelluläre Heterogenität, die Nährstoffverteilung, der Sauerstoffgradient, die Zell-Zell-Interaktionen sowie die Genexpression genauer abbilden und dadurch untersuchen. Arbeiten von Vinci sowie Howes et al. haben gezeigt, dass adäquate In-vitro-Bedingungen notwendig sind, um die Wirkungen von Medikamenten nicht zu über- beziehungsweise unterschätzen (Vinci et al. 2012, Howes et al. 2007). Ziel dieser Arbeit war, ein Verfahren zu etablieren, welches Sphäroide in einen tissue microarray zur Testung von potenziellen neuen Therapeutika zur Verfügung stellt, wobei in dieser Arbeit die Anwendung von kaltem Atmosphärendruckplasma und gepulsten elektrischen Feldern im Mittelpunkt des Interesses stand. Diese Methode von Ivanov und Grabowska (Ivanov & Grabowska 2017) wurde dazu in leicht modifizierter Form angewandt. Verwendet wurden zwei Melanomzelllinien (SK-Mel-28 MNT-1), für die zunächst optimale Wachstumsparameter festgelegt werden mussten, um stets vergleichbare und reproduzierbare Sphäroide mit einer Größe von 300-500 µm zu erhalten. Das etablierte Verfahren ist zeitsparender und ermöglicht eine automatische Bildaufnahme im Hochdurchsatz (high throughput screening) von bis zu 60 Sphäroiden pro Präparat. Die Immunfluoreszenzfärbung stellt aufgrund ihrer hohen Sensitivität und der dadurch möglichen Verkleinerung der Proben eine der wichtigsten Detektionsmethoden der Zukunft dar (Hertzberg et al. 2000). Es wurden parallel vier verschiedene Farbstoffe (DAPI, AlexaFluor 488, Alexafluor 594, AlexaFluor 647) mit zu testenden Targets markiert und mittels des CLS-Gerätes aufgenommen sowie quantitativ ausgewertet. Exemplarisch wurden 21 Fluorophore, innerhalb von sieben thematischen Sets und vier verschiedenen Behandlungsformen (direkte, indirekte Plasmabehandlung, H2O2-Behandlung, µsPEF-Behandlung) betrachtet. Hierdurch wurden unterschiedliche Plasma-induzierende Effekte auf die Zellmorphologie sowie ansatzweise auf die Verteilung innerhalb der Sphäroide untersucht. Bereits lichtmikroskopisch ließen sich eine Auflockerung der Peripherie sowie eine Verdichtung der zentralen Regionen der Sphäroide nach einer direkten Plasmabehandlung beobachten. Mittels der Immunfluoreszenz wurden sowohl bekannte Plasmaeffekte, wie die Apoptoseinduktion plasmabehandelter SK-Mel-28-Sphäroide mit hohen Plasmabehandlungsintensitäten, als auch verschiedene Signalwege, wie die antioxidative Zellantwort, beobachtet. Teilweise wurden kontroverse Ergebnisse gemessen, die die Notwendigkeit der Heterogenitätsanalyse innerhalb der Sphäroidschnitte aufzeigen. Beispielsweise weist die aufgelockerte Peripherie eine besonders hohe Apoptoserate auf, die mittels der TUNEL-IF-Färbung detektiert wurde (Abb. 38; Abb. 39). Zu der gesteigerten Apoptoserate lässt sich eine verstärkte Expression von HMOX1 bei den SK-Mel-28-Sphäroiden nach einer direkten sowie indirekten Plasmabehandlung nachweisen (Abb. 44). Hierraus lassen sich grundsätzliche Plasmaeffekte ableiten, wie die Einbringung von ROS und RNS. Zudem konnte die Größenreduktion der Sphäroiddurchmesser mittels µsPEF-Behandlung sowohl lichtmikroskopisch (Abb. 33) als auch am CLS-Gerät über die Gesamtfläche (Abb. 37) gezeigt werden. Diese Ergebnisse entsprechen denen von Nuccitelli et al. am Mausmodell (Nuccitelli et al. 2006, Nuccitelli et al. 2009). Des Weiteren wurden alternative Methoden angewandt, durch die die Antikörperverteilungen in ganzen Sphäroiden untersucht werden könnte (vgl. Kapitel 3.4.4).
Insgesamt liefert diese Methode, aufgrund der schnelleren sowie kostengünstigeren Durchführbarkeit und der potenziellen Automatisierung am CLS-Gerät, ein ausgesprochen mächtiges Verfahren zur Erforschung neuer Krebstherapien im Labor.
Background
The approval of ethanol by the Biocidal Products Regulation has been under evaluation since 2007. This follows concern over alcohol uptake from ethanol-based hand rubs (EBHR). If ethanol is classified as carcinogenic, mutagenic, or reprotoxic by the European Chemicals Agency (ECHA), then this would affect infection prevention and control practices.
Aim
A review was performed to prove that ethanol is toxicological uncritical and indispensable for hand antisepsis because of its unique activity against non-enveloped viruses and thus the resulting lack of alternatives. Therefore, the following main points are analyzed: The effectiveness of ethanol in hand hygiene, the evidence of ethanol at blood/tissue levels through hand hygiene in healthcare, and the evidence of toxicity of different blood/tissue ethanol levels and the non-comparability with alcoholic consumption and industrial exposure.
Results
EBHR are essential for preventing infections caused by non-enveloped viruses, especially in healthcare, nursing homes, food industry and other areas. Propanols are effective against enveloped viruses as opposed to non-enveloped viruses but there are no other alternatives for virucidal hand antisepsis. Long-term ingestion of ethanol in the form of alcoholic beverages can cause tumours. However, lifetime exposure to ethanol from occupational exposure < 500 ppm does not significantly contribute to the cancer risk. Mutagenic effects were observed only at doses within the toxic range in animal studies. While reprotoxicity is linked with abuse of alcoholic beverages, there is no epidemiological evidence for this from EBHR use in healthcare facilities or from products containing ethanol in non-healthcare settings.
Conclusion
The body of evidence shows EBHRs have strong efficacy in killing non-enveloped viruses, whereas 1-propanol and 2-propanol do not kill non-enveloped viruses, that pose significant risk of infection. Ethanol absorbed through the skin during hand hygiene is similar to consumption of beverages with hidden ethanol content (< 0.5% v/v), such as apple juice or kefir. There is no risk of carcinogenicity, mutagenicity or reprotoxicity from repeated use of EBHR. Hence, the WHO Task Force strongly recommend retaining ethanol as an essential constituent in hand rubs for healthcare.
Analyse der Situation der Krankenhaushygiene in Ghana während eines 3-monatigen Studienaufenthaltes
(2016)
Ziel war es, das Ausmaß nosokomialer Infektionen sowie die Hygienestrategien zur Prävention nosokomialer Infektionen und zur Eindämmung der bakteriellen Resistenzentwicklung in Entwicklungsländern am Beispiel von Ghana darzustellen. Weiterführend sollte das Problembewusstsein des medizinischen Personals in Ghana zu diesem Thema untersucht werden. Mit Hilfe eines Fragebogens wurden im Jahr 2008 in 19 zufällig ausgewählten Krankenhäusern in ganz Ghana 26 Ärzte, Studenten und Schwestern zur Krankenhaushygiene, zu nosokomialen Infektionen und zur bakteriellen Resistenzentwicklung befragt. Aufgrund der kleinen Stichprobe sind die Ergebnisse mit Vorbehalt zu bewerten. Knapp 2/3 der Befragten gaben an, die Problematik nosokomialer Infektionen zu kennen, jedoch wurden die Infektionsraten sehr niedrig eingeschätzt. Nur an Universitätskliniken tätige Ärzte und Studenten schätzten die Prävalenz nosokomialer Infektionen vergleichsweise hoch ein. Surveillance-Systeme existieren nicht. Trotzdem berichten 42 % der Teilnehmer von einem Dokumentationssystem in ihrer Einrichtung. 78 % der Befragten schätzten den Anteil der Patienten, die Antibiotika erhalten auf 40 bis 80 %. Zudem gaben 62% an, dass diese auch ohne Rezept erhältlich sind. 62 % waren davon überzeugt, dass die Resistenzentwicklung ein Problem darstellt. Jedoch waren damit häufig Malariaerreger gemeint. Nur 35 % veranlassen unter verschiedenen Umständen ein Antibiogramm. Meist wird dieses erst durchgeführt, wenn eine bereits begonnene Antibiotikatherapie keine Besserung zeigt. Häufig gibt es keine Möglichkeit für Laboruntersuchungen. Studien zeigen, dass beträchtliche Erregerresistenzen in Ghana bestehen. Diese werden auf Grund unzureichender Untersuchungen jedoch nicht erkannt und der Antibiotikaabusus wird nicht eingedämmt. 42 % der Befragten hatten keine Kenntnis über gesetzliche Grundlagen zu Krankenhaushygiene. Mit 92 % gaben jedoch fast alle Teilnehmer an, dass krankenhausinterne Hygienerichtlinien existieren. 75 % dieser Teilnehmer empfanden die bestehenden Hygienerichtlinien als adäquat und 21 % als teilweise umgesetzt. Auf genaue Nachfrage führten jedoch nur 15 % der Befragten eine korrekte Händedesinfektion durch. Dies spiegelt sich auch in eigenen Beobachtungen wider. Am Ende des Fragebogens wurde diese Frage wiederholt. Statt der 69 % aller Befragten hielten nun nur noch 42 % die Hygienerichtlinien für adäquat umgesetzt. 42% versicherten die Überwachung von Hygienemaßnahmen. 55 % dieser Befragten gaben an, dass eine Hygieneschwester für diese Kontrolle verantwortlich sei. Über die Möglichkeit einer Weiterbildung im Fach Hygiene waren nur 62 % informiert. Zu Fragen der Wasserhygiene und Finanzierung wirkten alle Befragten unsicher und es wurden divergente und damit nicht aussagekräftige Antworten gegeben. Es wurde deutlich, dass die Problematik nosokomialer Infektionen, die im Ergebnis der Literaturrecherche in Ghana besteht, von einem großen Teil der Befragten unterschätzt wird. Das Wissen über Zusammenhänge der Entstehung bis hin zu den Konsequenzen nosokomialer Infektionen und der bakteriellen Resistenzentwicklungen ist trotz adäquater Lehre mangelhaft. Daraus resultieren eine unzureichende Compliance bei der Umsetzung von Hygienemaßnahmen und ein inadäquater Umgang mit Antibiotika. Als Fazit ergibt sich großer Handlungsbedarf im Kampf gegen nosokomiale Infektionen, wobei der erste Schritt für die notwendige Etablierung und adäquate Umsetzung von Hygienemaßnahmen in der Entwicklung eines Problembewusstseins unter dem medizinischen Personal besteht.
Durch in vitro-Studien konnte gezeigt werden, dass Polihexanid im Vergleich zu anderen bekannten antimikrobiellen Wirkstoffen sowie in Anwesenheit anwendungsnah simulierter organischer Belastungen ein für die Wundantisepsis geeigneter Wirkstoff ist. Im Kontext mit den bekannten Daten zur Verträglichkeit zumindest im Bereich der medizinischen Anwendungskonzentrationen (0,02 % und 0,04 % Polihexanid) und zum Einfluss auf die Wundheilung stützen die hier erhobenen Daten die bestehende Konsensusempfehlung zur Wundantiseptik, nach der Polihexanid zwar auch zur akuten Wundantiseptik, insbesondere aber zur Behandlung chronischer Wunden als geeignet angesehen wird. Auf Basis der biochemischen und biopysikalischen Grundlagen der Wirksamkeit von Polihexanid wurde die Möglichkeit der weiteren Verminderung der Zytotoxizität des Polihexanids bei gleichzeitiger Aufrechterhaltung der bakteriziden Wirksamkeit durch die Bindung an Phosphatidylcholin-haltige o/w-Emulsionen gezeigt; im Testsystem bei gleichzeitiger Anwesenheit von Bakterien und eukaryotischen Zellen unter simulierten Wundbedingungen war bereits die Kombination 0,05 % PHMB / 0,4 % EPC vollständig bakterizid und dabei ohne zytotoxischen Effekt wirksam. Diese Darreichungsform fungiert weiterhin als PHMB-Depot, das auch nach wiederholter Passage durch eine Bakteriensuspension noch die gleiche wundantiseptische Wirksamkeit aufweist wie in der ersten Passage. Erste in vitro- und in vivo-Erfahrungen mit den hier beschriebenen PHMB-haltigen o/w-Emulsionen wurden bereits durch andere Arbeitsgruppen publiziert. Demnach führt diese neue Darreichungsform zu einer größeren Eindringtiefe des Wirkstoffs in die Haarfollikel, die in Bezug auf die Hautfläche das mit Abstand größte Reservoir für die mikrobielle Hautflora und nicht zuletzt auch für eine Repopulation oberflächlich desinfizierter Haut darstellen. Die in vivo–Daten deuten darauf hin, dass mit partikel-gebundenem PHMB eine bessere und nachhaltigere Antisepsis erreicht werden kann als mit freiem PHMB. Zusätzlich zum Beitrag an der Konsensusempfehlung des Polihexanids zur Behandlung chronischer Wunden wird damit als wesentliches Ergebnis der Dissertation die Erschließung von bisher für wässrige PHMB-Lösungen nicht möglicher medizinischer Einsatzorte wie in sensiblen Geweben oder Anwendung bei Neugeborenen, am Auge, in Gegenwart von Knorpel, am Peritoneum und in anderen Körperhöhlen (Blase, Harnröhre, vereiterte Gelenkhöhlen), zur Mukositis-Prophylaxe, bei der Krebschemotherapie, bei Verbrennungen 3. Grades, aber auch in der antimikrobiellen Behandlung von Zellkulturen vorstellbar. Bis zu einer solchen therapeutischen Nutzung sind jedoch noch weitere Studien notwendig. Als günstig dürfte sich erweisen, dass es sich sowohl beim Polihexanid, als auch bei dem hier verwendeten Lipofundin ® um bereits etablierte und gut verstandene Medizinprodukte handelt. Im Kontext der weltweit zunehmenden Antibiotikaresistenzen und Verbreitungswege nosokomialer Erreger bei entsprechend geringer werdenden chemotherapeutischen Interventionsmöglichkeiten durch Antibiotika gewinnt die Möglichkeit des Einsatzes von Antiseptika mit breitem Wirkungsspektrum und guter Verträglichkeit immer mehr an Bedeutung, und dabei auch umso mehr die Erweiterung bestehender Einsatz-Indikationen. Neben der auf den ersten Blick vordringlich erscheinenden Identifikation neuer Wirkstoffe kann nicht zuletzt auf Basis der hier vorgelegten Ergebnisse die auf das gewünschte Wirkumfeld zugeschnittene Modifikation der Darreichungsform bekannter antiseptischer Wirkstoffe als möglicher Weg zur verbesserten antimikrobiellen Therapie herausgestellt werden. Diesem Gedanken folgen beispielsweise bereits Versuche, die die besonderen Eigenschaften von Nanopartikeln oder Peptid-basierten Nanostrukturen für die Bekämpfung von Infektionen und Kolonisationen zu nutzen, wobei deren Einsatz wegen der zum Teil hohen ökologischen Fremdartigkeit für biologische Systeme kritisch evaluiert werden muss. Im Gegensatz dazu ähnelt die Wirkung des Polihexanids auf die zwangsläufig und physiologisch kaum modifizierbar negativ geladenen bakteriellen Zellwandstrukturen dem Wirkmechanismen natürlich vorkommender antibakterieller Peptide wie dem β-Defensin, die einen wesentlichen Bestandteil des evolutionär sehr alten, angeborenen Immunsystems der Vertebraten darstellen – mikrobielle Zellumhüllungen sind anfällig gegenüber polykationischen Verbindungen mit hydrophoben Domänen. Auch das stellt einen Vorteil des Polihexanids gegenüber anderen Antiseptika dar.
Die Zahl von Parodontitispatienten steigt jährlich an. Außerdem wurden vermehrt Implantate insertiert, die analog zur Parodontitis von Periimplantitis betroffen sind. Ursächlich für beide Erkrankungen sind Biofilme. Es gibt keine befriedigenden Methoden zur Biofilmentfernung, die außerdem eine wundheilungsfördernde Oberfläche erzeugen. Daher werden neue Behandlungsmethoden benötigt. In dieser Arbeit wurde drei Biofilmmodelle mit C. albicans, S. mutans und Speichelmikroorganismen mit drei verschiedenen Plasmaquellen (kINPen09, Hohlelektroden-DBD, Volumen-DBD) sowie zwei verschiedenen Gasmischungen (Argon und Argon+1% O2) jeweils 1, 2, 5 und 10 min mit Plasma behandelt. Als Positivkontrolle wurde Chlorhexidin mitgeführt. Außerdem wurden verschiedene Titanbearbeitungsformen (maschiniert, diamantbearbeitet, pulverbestrahlt sowie geätzt und gestrahlt) mit Argon+1%O2-Plasma mittels kINPen09 behandelt. Anschließend wurden die Elementzusammensetzung, der Kontaktwinkel sowie die Ausbreitung von osteoblastenartigen Zellen MG-63 auf diesen Oberflächen bestimmt. SLactive􀂓 wurde hierbei als Positivkontrolle verwendet. Um eine potentielle Anwendung in der Parodontologie zu prüfen, wurden diese Untersuchungen auch auf Dentin durchgeführt. Alle Plasmaquellen und –parameter wirkten antimikrobiell. Die Zerstörung der Zellen wurde im Rasterelektronenmikroskop deutlich. Hierbei reduzierte die Volumen-DBD die Koloniebildenden Einheiten um circa 5 log-Stufen und wies damit die höchste antimikrobielle Wirksamkeit auf. Sauerstoffzumischung führte nur bei der Hohlelektroden-DBD zu einer erhöhten antimikrobiellen Wirksamkeit. Die Plasmabehandlung reduzierte die Kontaktwinkel auf allen Oberflächen teilweise bis in den superhydrophilen Bereich. EDX-Analysen zeigten eine Reduktion der Masseprozent von Kohlenstoff sowie eine Erhöhung des Sauerstoffgehalts aller Oberflächen nach Plasmabehandlung. Die Ausbreitung der Osteoblasten war auf den plasmabehandelten Oberflächen signifikant höher als auf den unbehandelten Oberflächen und konnte sogar die Werte der hydrophilen SLactive􀂓-Oberfläche übersteigen. Diese Effekte konnten sowohl auf Titan als auch auf Dentin nachgewiesen werden. Da Plasma antimikrobiell wirkt und, wie in weiterführenden Versuchen gezeigt werden konnte, auch Biofilm entfernt, eignet es sich zur Therapie der Periimplantitis und Parodontitis. Außerdem wird die Oberfläche biokompatibler, wodurch die Wundheilung gefördert werden könnte. Da Plasma weitere wundheilungsstimulierende Faktoren beinhaltet, stellt es in Zukunft eine Erfolg versprechende Therapieoption für die Behandlung von Parodontitis und Periimplantits dar.
Background: In clinical practice, treatment of genital tract infections is based on administration of either antibiotics or antiseptics. While antibiotics may be applied systemically or topically, antiseptics may be applied only topically. In case of bacterial vaginosis (BV), antibiotic therapy may often be limited and side effects due to systemic administration may develop. Polihexanide (PHMB) is a promising option for the topical treatment of genital tract infections, in particular BV and vaginitis. Method: A systematic search for publications on the use of PHMB for the treatment of genital infections in two electronic databases was performed. Titles, abstracts and citations were imported into a reference database. Duplicates were removed and two reviewers assessed each identified publication separately. Results: Among a total of 204 references, 3 prospective randomized trials were identified. Two trials treated BV infections with PHMB in comparison to clindamycin as antibiotic standard therapy with no significant differences either in safety or in efficacy. The third controlled trial investigated the clinical efficacy of PHMB compared to placebo in the treatment of human papilloma virus. Patients treated with PHMB daily for up to 16-weeks showed significantly higher (52%) clearance of genital warts as compared to patients treated with placebo (4%). Conclusion: PHMB may be a clinically effective alternative for the treatment of BV and human papilloma virus. Although PHMB-based antiseptics are available since the late 90s, controlled trials to investigate its clinical potential for antiseptic treatment are scant. Clinical use of antiseptics for the treatment of infectious diseases should be explored and supported further.
Ziel der Studie war die Beurteilung der Notwendigkeit einer routinemäßigen desinfizierenden Fußbodenreinigung im Greifswalder Zentral-OP (Neubau) mit besonderer Berücksichtigung der Raumlufttechnischen Anlage (RLT-A). Dazu wurden über einen Zeitraum von 4 Wochen die 2 OP-Säle der Augenchirurgie jeweils abwechselnd im Wochentakt einer Wischdesinfektion nach jeder OP bzw. nur bei sichtbaren Verschmutzungen unterzogen. Für den Vergleich der Luftqualität wurden Partikel- und Koloniezahlen der Raumluft inner- und außerhalb des Laminar Air Flow (LAF) sowie die Erregerbelastung im OP-Gebiet (Instrumententray und OP-Tisch) erfasst. Außerdem erfolgte die Überprüfung evtl. aufgetretener postoperativer Wundinfektionen innerhalb eines Jahres. Sowohl Partikel- als auch Luftkoloniezahlen wiesen keine signifikanten Unterschiede bei Betrachtung des Wischvorgangs auf. Wurde die Anästhesieart berücksichtigt, fielen signifikant erhöhte Partikelwerte (< 5 µm) unter Intubationsnarkose (ITN) auf. Des Weiteren konnte eine Korrelation zwischen den Koloniezahlen auf dem Instrumententray und der OP-Dauer bei Wischen nach jeder OP festgestellt werden. Die einmal wöchentlich erhobene Fußbodenkontamination brachte keine signifikanten Unterschiede bezüglich des Einflusses der Wischdesinfektion. Es traten, soweit beurteilbar, innerhalb eines Jahres keine postoperativen Wundinfektionen auf. Daraus lässt sich schlussfolgern, dass eine desinfizierende Fußbodenreinigung unter dem Einfluss des LAF nicht notwendig ist, sondern eine gezielte Desinfektion bei sichtbaren Verschmutzungen bzw. Kontamination mit Blut oder anderem erregerhaltigem Material ausreicht. Aus wirtschaftlicher und organisatorischer Sicht ist das vorteilhaft. Die OP-Dauer sollte grundsätzlich so gering wie möglich gehalten werden, da eine Korrelation zur Instrumentenkontamination nachgewiesen wurde.
Im Rahmen eines Forschungsprojekts im Bereich der Odermündung wurde ein Pflanzentest für aquatische Verunreinigungen gesucht. Der Test wurde nach einem Testprotokoll von Everiss (1979) etabliert. Als Endpunkte gingen die Frischmasse und die Gesamtsprossen ein. Die Testlösungen wurden aus einer konzentrierten Mischung von 7 Schwermetallen und Arsen (As, Hg, Cd, Cr, Cu, Ni, Pb, Zn) und als Einzelsubstanzlösungen hergestellt. Die Auswertungen erfolgten in Prozent bezogen auf die Kontrolle sowie varianzanalytisch nach OECD (2002). In 100facher NKO (NKO = mittlere Konzentration Oderwasser Oberhalb der Nachweisgrenze) wurde eine schwere Schädigung durch alle Gemische verursacht. Das Gemisch ohne Cr schädigte am stärksten. In 10facher NKO konnte eine Wachstumshemmung nachgewiesen werden. Bei 1facher NKO zeigte sich eine geringe Beeinflussung. Als Einzelstoff war Cu in 100facher NKO am stärksten toxisch, gefolgt von Zn, Ni und Cd. As, Pb, Hg und Cr wirkten nicht eindeutig wachstumshemmend. In 10facher NKO war bei Cd, Cu und Zn noch Schädigung vorhanden. Kupfer wirkte auch in der 1fachen NKO noch schädigend. Bei Cd zeigte sich noch eine Reduktion des Sprosswachstums, aber keine Frischmassereduktion. Der L. minor - Test ist sensitiv und eignet sich als Screeningtest für unbekannte Gewässerproben. Er stellt eine gute Ergänzung zu anderen Biotestverfahren dar. Für eine umwelttoxikologische Einschätzung wird anhand der erzielten Ergebnisse ein Schädigungsmodell vorgeschlagen.
Für den zukünftigen Einsatz von Niedertemperaturplasma in Bereichen der Medizin müssen potentielle genotoxische Risiken von Plasma ausgeschlossen werden. Bisherige Risikoanalysen sind durch die unterschiedlich existierenden Plasmaquellen erschwert, die in den energetischen Einstellungen und Konzentrationen der reaktiven Sauerstoffspezies (ROS) variieren können. Zur Untersuchung des mutagenen Risikopotentials von Argonplasma, erzeugt mit den Plasma-Jets kINPen MED und kINPen 09, wurde auf dem Micronucleustest am angebrüteten Hühnerei (HET-MN), der eine Alternativmethode zwischen in-vitro und in-vivo Tests ist, zurückgegriffen. Die Plasmabehandlung mit Argongas erfolgte in unterschiedlichen Behandlungszeiten am 8. Bebrütungstag auf der inneren Membran des Hühnerembryos. Nach der Blutentnahme am 11. Tag, wurde das Blut im Blutausstrich auf das Vorhandensein von Micronuclei (MN) untersucht. Die gezählten MN der definitiven Erythrozyten (E II) dienten zur Bestimmung der Genotoxizität (MNE II). Die Ergebnisse der Plasmabehandlung mit dem kINPen MED ergaben in der Höchstdosis von einer Behandlungszeit von 10 min keine erhöhten MNE II Werte, obwohl die akute Toxizität bei > 40 % lag. Mit dem kINPen 09 konnten bei einer maximalen Behandlungsdauer von 2,5 min ebenfalls keine erhöhten MNE II Häufigkeiten ermittelt werden. Möglicherweise haben die im Hühnerembryo vorkommenden Abwehr- und Reparatursysteme gegenüber ROS das negative Ergebnis beeinflusst.
Analyse der Hygienekosten in einer Zahnklinik am Beispiel der AOK Rheinland/Hamburg in Düsseldorf
(2013)
Die Umsetzung gesetzlicher Anforderungen sowie der Richtlinien des RKI und des DAHZ tragen wesentlich zur Erhaltung der Hygiene in der zahnärztlichen Praxis bei. Das erhöht die Qualität der zahnärztlichen Behandlung und minimiert die Risiken, die hygienebedingt die Gesundheit des behandelnden zahnärztlichen Teams und des Patienten gefährden können. Andererseits stellt ein kontinuierliches Schritthalten mit den technologischen Fortschritten und Vorgaben der Hygienemaßnahmen ein betriebswirtschaftliches Thema für die Zahnarztpraxis dar, weil zwischen der Qualität der Leistungen einer Zahnarztpraxis und den Aufwendungen zur Gewährleistung der Qualität eine ökonomisch vertretbare Relation bestehen muss, wenn die Zahnarztpraxis langfristig erhalten bleiben soll. Die Analyse der Hygienekosten der Zahnklinik der AOK im Jahr 2010 zeigte, dass die wesentlichen angefallenen Kosten für die Unterbindung der Infektionsverbreitung auf den Wegen aufgewendet worden sind, die in dieser Arbeit unter Hygienesachkosten zusammengefasst wurden. Sie ergaben in der Summe 66.721,22 €. Gemäß der Analysenergebnisse stellen die Kostenarten Personalkosten (PK) und Medizinprodukte (G1) die zwei wesentlichen Anteile der Kosten der Zahnklinik der AOK mit einem Anteil von ca. 72 % Kosten dar (entsprach 92.061,07 €). Die Verwendungszwecke der Personalkosten umfassen arbeitsmedizinische Untersuchungen, Schutzimpfungen, Reinigungskraft und Sterilisationsdienst, wobei Schutzimpfungen den niedrigsten und der Sterilisationsdienst den höchsten Kostenanteil verursachten. Die übrigen Kosten verteilten sich wie folgt: Berufs- und Schutzkleidung 14.892,00 €, Antiseptika 1.216,18 €, Zertifizierung und Qualitätsmanagement 7.667,00 €, Geräte 12.411,74 €. Damit ergibt sich ein Gesamtbetrag für die Hygienekosten für das Jahr 2010 von 128.247,99 €. Eine Prognose der Hygienekosten auf Grund der Kostenerfassung für vier Quartale eines Jahres ist nicht möglich, da dieses Vorgehen unrealistische Ergebnisse liefert. Es wird daher empfohlen, für eine Prognose die Daten von mindestens drei aufeinander folgenden Jahren zu verwenden.
Im Routinebetrieb des PTS waren keine potentiell pathogenen Erreger an durch das PTS geschickten und mit physiologischer Kochsalzlösung getränkten, zur Reinigung vorgesehenen Schwämmchen nachweisbar.
In Übereinstimmung dazu war die Empfangsstation bei 9 von 20 Probennahmen ebenfalls nur mit KNS und aeroben Sporenbildnern kontaminiert.
In der aus dem PTS in die Empfangsstation strömenden Luft war die Anzahl luftgetragener Erreger geringer als in der Umgebungsluft außerhalb des Ausströmbereiches des PTS.
Die Untersuchungsergebnisse bestätigen, dass bei monatlicher Dekontamination des PTS keine Übertragung potentieller Pathogene stattfindet.
Dagegen waren die Eingaberacks (12 Probennahmen) ausnahmslos kontaminiert, davon zweimal mit Schimmelpilzen und einmal mit Enterococcus faecium. Deshalb sollte die vom Hersteller nur monatlich empfohlene maschinelle Reinigung wöchentlich durchgeführt werden.
Da die experimentell vorgenommene bakterielle Beladung der Probenröhrchen weit höher war als sie in praxi selbst bei schlechter Händehygiene vorkommen kann, um den worst case zu simulieren, ist bei hygienischer Wartung der Anlage gemäß Herstellerempfehlung eine Weiterverbreitung von Krankheitserregern über das PTS auszuschließen.
Damit konnte die der Studie zugrunde gelegte Frage ausgeschlossen werden, ob das PTS an der Verbreitung von VRE beteiligt war.
Vielmehr stellte sich heraus, dass Mängel in der Schlussdesinfektion der Patientenzimmer nach der Entlassung von mit VRE kolonisierten Patienten die Ursache des Ausbruchs war (Kramer 2014).
Bei der Prüfung mikrobiozider Wirkstoffe im quantitativen Suspensionsversuch muss die sog. Nachwirkung von in die Subkultur verschleppten Wirkstoffspuren ausgeschaltet werden, weil andernfalls eine zu hohe Wirksamkeit vorgetäuscht wird. Deshalb wurde die Neutralisierung der oberflächenaktiven kationischen Antiseptika Chlorhexidindigluconat, Octenidindihydrochlorid und Polyhexamethylenbiguanidinhydrochlorid durch Lipofundin MCT 20 % bei Einsatz von E. coli, S. aureus, P. aeruginosa, E. hirae und C. albicans gemäß DIN EN 13727 untersucht. Zu 8 Volumenanteilen Inaktivator (Lipofundin) wurden zunächst 1 Volumenanteil Wirkstofflösung hinzugefügt. Nach 5 min Kontakt bei Raumtemperatur wurde dann die Mischung mit 1 Volumenanteil Prüfmikroorganismen mit einer Dichte von 104 KbE/ml versetzt, gründlich gemischt und anschließend die vorhandenen KbE quantifiziert. Um die Neutralisierungskapazität von Lipofundin genauer zu bestimmen, wurde abweichend von der Empfehlung der Norm, wonach die KbE-Anzahl nach Neutralisierung unter der Hälfte der KbE-Anzahl in der Kontrolle betragen muss, als Maßstab ein fehlender signifikanter Unterschied zwischen beiden Ansätzen zugrunde gelegt. Die Ergebnisse zeigen, dass CHX, OCT und PHMB durch die Bindung an die Phospholipidschicht des Lipofundins konzentrationsabhängig neutralisiert wurden, was zu einem Weiterwachstum von E. coli, S. aureus, E. hirae, P. aeruginosa und C. albicans geführt hat. Damit erwies sich Lipofundin als effektiver Neutralisator. Im Vergleich zu CHX und OCT war der Konzentrationsbereich für die Neutralisierung bei PHMB allerdings kleiner. Daraus lässt sich umgekehrt ableiten, dass PHMB in Gegenwart von Phosphatidylcholin weniger an mikrobiozider Wirkung einbüßt als OCT und CHX, was für die antiseptische Anwendung vorteilhaft sein könnte.
Ausgehend von der Hypothese, dass die präoperative Vorbereitung der Unterarme der Hautantiseptik an den Oberarmen durch die vergleichbare Beschaffenheit der Haut deutlich ähnlicher ist als der Desinfektion der Hände, werden diese beiden Areale mit einem modifizierten Verfahren nach standardisierten Prüfmethoden miteinander verglichen. Es soll untersucht werden, ob es möglich ist, unter Reduktion der Applikationszeit an den Unterarmen entsprechend der Richtlinien der Antiseptik die gleiche Wirkstärke wie zur Vorbereitung vor Injektionen am Oberarm zu erreichen. Diese Wirkstärke wird als zur präoperativen Vorbereitung an den Unterarmen ausreichend postuliert. Zur Prüfung wird ein sowohl für die chirurgische Händedesinfektion als auch für die Hautantiseptik zertifiziertes Präparat auf Ethanolbasis ausgewählt. Das Prüfpräparat wird auf seine Koloniezahlreduktion am Unterarm nach 2,5 min, 30 min und. 3 h, bzw. am Oberarm nach 15 s, 2,5 min und 30 min Einwirkzeit in Anlehnung an die DIN 12791 und die Richtlinien zur Prüfmethodik des VAH für die Hautantiseptik geprüft, um durch den Vergleich der Wirkstärke auf beiden Arealen ein schlüssiges Konzept für die chirurgische Händedesinfektion ableiten zu können. Im Folgeversuch beschränken wir uns im Rahmen einer Pilotstudie auf den Vergleich der Wirkung am Unterarm nach 2,5 min mit der am Oberarm nach 15 s an 12 Probanden. Im Ergebnis ist eine der zertifizierten Wirkung am Oberarm entsprechende Wirkung am Unterarm durch 2 x 5 s andauerndes Benetzen erreichbar. In der ergänzenden Pilotstudie wird am Unterarm nach nur 5 s Applikationszeit im Nachwert nach 2,5 min eine entsprechende Keimzahlreduktion erreicht. Diese bedarf allerdings durch Erhöhung der Stichprobenzahl der Verifizierung. Die Behaarung zeigt keinen Einfluss auf die Desinfizierbarkeit am Unterarm. Als Resultat der Untersuchungen kann eine Änderung der Durchführung der chirurgischen Händedesinfektion empfohlen werden. Die von der DGHM vorgeschriebenen 1,5 min für die Desinfektion der Hände sind an den Unterarmen nicht notwendig. Hier scheint durch 5 s andauerndes Benetzen bereits eine ausreichende Desinfektionswirkung erreichbar. Damit ist eine deutliche Vereinfachung und sichere Standardisierung im Ablauf der chirurgischen Händedesinfektion möglich.
Händedesinfektionsmittel können durch bestimmte Agenzien wie z. B. Hautcremes beeinflusst werden. Fragestellung der Arbeit war, ob die Interaktion von einem alkoholischen Händedesinfektionsmittel mit zwei verschiedenen Massagemitteln die Wirksamkeit der Händedesinfektion beeinflusst. Der Hauptversuch war eine Desinfektionsstudie, angelehnt an die EN 1500, mit 21 Probanden. Nach Kontamination mit E. coli wurden Vorwerte ermittelt, dann fand eine 20-minütige Massage statt, anschließend wurde das Massagemittel mit Papierhandtüchern abgerieben, die Händedesinfektion durchgeführt und Nachwerte ermittelt. Darauf aufbauende Untersuchungen beinhalteten zum einen Experimente über die Bedeutung des Abreibens mit Papierhandtüchern und über die Überlebensrate der Bakterien nach der Massage. Zum anderen sollten die Untersuchungen zeigen, ob von Massagemittel eingeschlossene Erreger im Gegensatz zu Erregern an der Oberfläche der Mittel erschwert an die Probesammelflüssigkeit abgegeben werden und wie die Desinfektionseffizienz von auf dem Massagemittel liegenden, nicht einmassierten Bakterien ist. Beim Hauptversuch sowie beim Versuch ohne Papierhandtücher waren die Reduktionsfaktoren der Massagegruppen signifikant höher als die der Referenzgruppe. Die folgenden Experimente ergaben, dass möglicherweise ein Teil der E. coli Bakterien während der Massage abstirbt. Des Weiteren ergaben unsere Resultate, dass von Massagemittel eingeschlossene Bakterien kaum an das Probesammelmedium abgegeben werden, wohingegen oberflächlich auf dem Massagemittel befindliche Bakterien ohne Probleme in die Sammelflüssigkeit gelangen. Findet die Desinfektion von oberflächlich auf den Massagemittel liegenden nicht massierten Bakterien statt, so gibt es keine signifikanten Unterschiede zwischen den Reduktionsfaktoren. Es gibt zwar im Hauptexperiment signifikante Unterschiede zwischen den verschiedenen Reduktionsfaktoren. Jedoch ist das darauf zurückzuführen, dass die Bakterien möglicherweise während der Massage teilweise absterben bzw. die Abgabe an das Sammelmedium durch die Massagemittel behindert wird. Als Schlussfolgerung kann abgeleitet werden, dass Physiotherapeuten wahrscheinlich ihre Hände nach der Massage desinfizieren können, ohne dass die Desinfektionsleistung des alkoholischen Präparates dadurch herabgesetzt wird. 72 Um das Ergebnis zu verifizieren, sollten in Zukunft Versuchsabläufe geplant werden, bei denen die Massagezeit kürzer gewählt wird, um den Fehlerfaktor des Bakterienabsterbens zu minimieren.
Contaminated surfaces have been discussed as a possible source of severe acute respiratory
syndrome coronavirus-2 (SARS-CoV-2). Under experimental conditions, SARS-CoV-2 can remain
infectious on surfaces for several days. However, the frequency of SARS-CoV-2 detection on surfaces
in healthcare settings and the public is currently not known. A systematic literature review was
performed. On surfaces around COVID-19 cases in healthcare settings (42 studies), the SARS-CoV2 RNA detection rates mostly were between 0% and 27% (Ct values mostly > 30). Detection of
infectious SARS-CoV-2 was only successful in one of seven studies in 9.2% of 76 samples. Most of the
positive samples were obtained next to a patient with frequent sputum spitting during sampling.
Eight studies were found with data from public surfaces and RNA detection rates between 0% and
22.1% (Ct values mostly > 30). Detection of infectious virus was not attempted. Similar results
were found in samples from surfaces around confirmed COVID-19 cases in non-healthcare settings
(7 studies) and from personal protective equipment (10 studies). Therefore, it seems plausible to
assume that inanimate surfaces are not a relevant source for transmission of SARS-CoV-2. In public
settings, the associated risks of regular surface disinfection probably outweigh the expectable health
benefit
Biocidal Agents Used for Disinfection Can Enhance Antibiotic Resistance in Gram-Negative Species
(2018)
COVID-19 Vaccinated Individuals Can Be a Source of SARS-CoV-2 Transmission—A Systematic Review
(2021)
Fundamental rights are probably given back earlier to COVID-19 vaccinated individuals
assuming that they cannot spread SARS-CoV-2 anymore. The objective of the study was to determine
if COVID-19 vaccinated individuals can still be the source of SARS-CoV-2 transmission. PubMed
was searched for studies on 4 April 2021. All studies with original data on COVID-19 cases among
vaccinated individuals (phase III RCTs) and on viral load in the upper respiratory tract of vaccinated
macaques after a SARS-CoV-2 challenge were included. Symptomatic COVID-19 cases were found
in four trials among vaccinated participants although less frequently than among control subjects.
One study revealed asymptomatic COVID-19 cases in a similar frequency among 2.168 AZD1222-
vaccinated subjects (1.0%) compared to 2.223 control subjects (1.0%). In 15 studies with vaccinated
macaques, it was found that the load of SARS-CoV-2 RNA, subgenomic RNA and infectious virus
in the upper respiratory tract is variable. Sterilizing immunity was found in none of the animal
studies. Major limitations of the animal studies are that the SARS-CoV-2 challenge took place within
a few weeks of the final or only vaccine dose, that the viral challenge was often high and, in some
studies, administered by up to four routes. Based on current knowledge it seems clear that COVID-19
vaccinated individuals can still be the source of SARS-CoV-2 transmission.
Nosokomiale Infektionen, insbesondere die nosokomiale Sepsis, spielen auf der neonatologischen Intensivstation eine große Rolle, weil sie mit einer erhöhten Morbidität und Mortatlität verbunden sind. Da die Diagnosestellung bei Neonaten, insbesondere bei Frühgeborenen, schwierig ist, ist die Prävention der nosokomialen Sepsis äußerst wichtig. Die vorliegende Arbeit befasste sich mit der Analyse, ob es Risikofaktoren für eine mikrobiologische Kolonisation und dem Auftreten einer neonatalen Sepsis gibt und ob eine bakterielle Besiedlung der Neonaten mit dem Entstehen einer neonatalen Sepsis einhergeht. Zu diesem Zweck wurden in einem Zeitraum von 32 Monaten (2003-2006) alle Neonaten auf der Neo-ITS der Universitätsmedizin Greifswald, die den Kriterien für eine nosokomiale Sepsis entsprachen, in dieser Arbeit eingeschlossen (n=68). Um die erhobenen Daten dieser Kinder vergleichen zu können, wurden ebenfalls 68 Kinder, die keine Sepsis hatten, aus diesem Zeitraum nach entsprechenden Kriterien als Kontrollgruppe berücksichtigt, so dass die Gesamtfallzahl für diese Arbeit 136 betrug. Von den 136 Säuglingen wurden verschiedene peripartale Faktoren, wie beispielsweise Liegedauer, Geburtsgewicht, Mutteralter bei der Geburt, Geburtsort etc. erfasst. Zusätzlich kamen Ergebnisse eines routinemäßigen mikrobiologischen Monitorings hinzu. Die erhobenen Daten wurden mit SPSS ausgewertet. Im Ergebnis zeigten sich eine lange Liegedauer, ein geringes Aufnahmegewicht, das Vorkommen einer NEC und der Geburtsort Greifswald als signifikante Risikofaktoren für eine neonatale Sepsis. Ein weiterer tendenziell begünstigender Faktor für des Entstehen einer Sepsis war das Vorkommen von Fehlbildungen (p=0,06). Für eine mikrobiologische Kolonisation sind ebenfalls eine lange Liegedauer, ein geringes Geburts- bzw. Aufnahmegewicht und das Vorkommen einer NEC Risikofaktoren. Zusätzlich konnten auch geringes Gestationsalter und längere Dauer der Muttermilchernährung als begünstigende Faktoren für eine Besiedlung der Neonaten bestimmt werden. Nach Unterteilung der Kolonisation in einzelne Bakterienspecies ergaben sich ähnliche Risikofaktoren. Es ergab sich kein Zusammenhang zwischen einer Kolonisation und einer neonatalen Sepsis, d. h. eine Kolonisation unabhängig von der Bakterienspecies stellt kein Risikofaktor für die Entwicklung einer Sepsis dar. In der vorliegenden Arbeit konnten verschiedene Risikofaktoren für das Auftreten einer neonatalen Sepsis und für die Besiedlung der Neonaten identifiziert werden, die bereits in der Literatur beschrieben wurden wie lange Liegedauer, geringes Geburtsgewicht, Fehlbildungen und NEC. Nach aktueller Studienlage korreliert auch ein geringes Gestationsalter mit dem Auftreten einer Sepsis, was in unserer Arbeit nicht bewiesen werden konnte. Da ebenfalls kein Zusammenhang zwischen einer bakteriellen Kolonisation und dem Entstehen einer neonatalen Sepsis gefunden wurde, bedeuten die in dieser Arbeit routinemäßig durchgeführten mikrobiologischen Abstriche keinen direkt-infektiologischen Vorteil.
Zusammenfassung Vor kurzem wurde bekannt, dass ein alkoholisches Händedesinfektionsmittel mit einer Anwendungszeit von nur 1,5 min zum ersten Mal den Anforderungen des europäischen Standards EN 12791 nicht nur entsprach, sondern diese sogar signifikant übertraf. Allerdings wurde der Effekt einer vorangehenden 1-minütigen Händewaschung und der sich anschließenden 1-minütigen Trocknungszeit des Alkohols nach der Anwendung bezüglich der Wirksamkeit der Desinfektion noch nicht untersucht. Um dieser Frage nachzugehen, wurden drei verschiedene Verfahren zur chirurgischen Händedesinfektion getestet: Verfahren A: 1 min Waschung + 1,5 min Desinfektion mit Sterillium®; Verfahren B: 1,5 min Desinfektion mit Sterillium® und Verfahren C: 1,5 min Desinfektion mit Sterillium® + 1 min Abtrocknungszeit. Diese wurden mit dem in der prEN 12791 festgelegten Referenzverfahren (1 min Händewaschung und 3 min Desinfektion mit Propan-1-ol) verglichen. Vor, direkt nach und 3 h nach der jeweiligen Anwendung eines Verfahrens wurde die Bestimmung der Koloniezahl an den Händen vorgenommen. Nach Bebrütung und Auszählung erfolgte aus diesen Werten die Berechnung der Sofort- und der Langzeitreduktion. Die Ergebnisse zeigten, dass alle drei aufgeführten Verfahren die Anforderungen der prEN 12791 für die chirurgische Händedesinfektion erfüllten bzw. zum Teil signifikant besser waren. Die Verfahren, in denen die Hände vor der Desinfektion gewaschen wurden, zeigten geringere Reduktionen der Koloniezahlen. Das Verfahren, dem sich nach der Desinfektion eine 1-minütige Trocknungszeit der Hände anschloss, zeigte eine signifikant bessere Effektivität in der Sofortwirkung. Die Reduktionsfaktoren in der Langzeitwirkung waren zwar auch absolut betrachtet höher als bei allen anderen Verfahren, jedoch war dieser Unterschied nicht signifikant. Somit lässt sich nach diesen Untersuchungen feststellen, dass die präoperative Händewaschung die Effektivität der alkoholischen Händedesinfektion nicht verbessert, sondern aufgrund eines Verdünnungseffekts des applizierten Alkohols durch den erhöhten Wassergehalt der Haut nach Seifenwaschung die Wirksamkeit sogar herabgesetzt wird. Durch eine 1-minütige Abtrocknungszeit kann hingegen die Effektivität der chirurgischen Händedesinfektion wegen der längeren Einwirkdauer verbessert werden, was der Realität entspricht. Allerdings wird in der prEN 12791 gefordert, die noch nasse Hand sofort nach der Desinfektion für die Probennahme zu verwenden. Daraus kann abgeleitet werden, dass die Wirkung der chirurgischen Händedesinfektion mit Alkoholen in der Realität besser ist, als in der Testung gemäß prEN 12791 suggeriert wird.
Korrekte Händehygiene ist ein maßgeblicher Faktor im medizinischen Pflegealltag zur Vermeidung von nosokomialen Infektionen. Dabei ist nicht nur die richtige Technik nach der EN1500 maßgeblich, sondern vor allem die Compliance des Pflegepersonals, die je nach Fachrichtung sowie einer Reihe von anderen Faktoren zwischen 5-96 % schwankt. Als ein maßgeblicher Grund für mangelnde Compliance wird im Pflegealltag die erforderliche Zeit für die Händedesinfektion angegeben, d.h. die vorgeschriebene Einwirkzeit von 30 s wird im normalen Pflegealltag als zu lange empfunden bzw. auf Grund von zu wenig Zeit werden die Hände zu wenig desinfiziert. In dieser Studie wurde geprüft, ob die minimale Einwirkzeit von 30 s auf 15 s bei gleichbleibender Effizienz herabgesetzt werden kann und ob sich die verkürzte Einwirkzeit auf die Compliance des Pflegepersonals auswirkt. Die Studie wurde als Cross-Over-Anwendungsbeobachtung an 14 Probanden auf einer gynäkologischen Bettenstation durchgeführt. Die Probanden wurde jeweils über eine 8 h Schicht begleitet; dabei wurden die Anzahl ihrer durchgeführten Händedesinfektionen und die Indikationen dazu an Hand der "5 Moments" (WHO-Guideline 2009) erfasst. Bei den Probanden wurde am Anfang ihrer Schicht sowie danach stündlich die Kontaminationsrate der Hände mittels Auskneten der Fingerkuppen in CSL-Lösung sowie Ausstreichen auf Blutagarplatten in verschiedenen Verdünnungsreihen bestimmt. Danach erfolgte eine Händedesinfektion mit entweder 15 s oder 30 s Einwirkungszeit und die eine weitere Bestimmung der mikrobiellen Last in CSL-Lösung mit Desinfektionshemmstoff nach demselben Muster. Die kurz vor der Probeentnahme zuletzt durchgeführten Tätigkeiten wurden an Hand der Fulkerson-Skala klassifiziert. Im Ergebnis der Studie konnte sowohl die Gleichwertigkeit der Effektivität der verkürzten Einwirkzeit der Händedesinfektion bei gleicher mikrobieller Belastung zwischen beiden Versuchsreihen nachgewiesen werden, d.h. im laufenden Pflegealltag besteht kein Unterschied innerhalb der mikrobiellen Reduktionsleistung zwischen 15 s und 30 s Einwirkzeit. Zugleich wurde festgestellt, dass sich die Compliance innerhalb der verkürzten Einwirkzeit von 15 s gegenüber der von 30 s um 15 % signifikant steigerte. Die verkürzte Einwirkzeit ist folglich nicht nur als gleichwertig gegenüber der bisherigen Einwirkzeit von 30s anzusehen, sondern sie erwies sich als sinnvoll zur Verbesserung der Compliance des Pflegeteams auf der untersuchten Station.
Zusammenfassung
Zielsetzung: Im Ergebnis einer Literaturrecherche konnten keine Studien zur Ermittlung der Anzahl notwendiger Indikationen der HD auf Nicht-Risiko-Stationen ermittelt werden. Daher sollte die Anzahl erforderlicher Händedesinfektionen auf zwei peripheren Nicht-Risiko-Stationen ermittelt werden, um auf dieser Grundlage die Compliance anhand von Verbräuchen abschätzen zu können. Bisher wird in der UMG der Verbrauch an Händedesinfektionsmitteln der unterschiedlichen Stationen nur über Abgabedaten der Apotheke ermittelt.
Methode: Auf einer neurologischen und einer chirurgischen Bettenstation der UMG wurden jeweils zehn Pflegekräfte und zehn Ärzt*innen hinsichtlich des Verhaltens der Händedesinfektion nach Training des Beobachtenden zur Datenerhebung durch eine Hygienefachkraft während der gesamten Schicht begleitet. Die Beobachtung je eines Mitglieds des Stationsteams wurde an allen sieben Wochentagen sowie zu allen Schichten (Früh-/Spät-/Nachtschicht) durchgeführt. Als Grundlage zur Ermittlung der Indikationsstellungen wurde das Modell der Five Moments der WHO gewählt. Mit Hilfe der Fulkerson-Skala wurden die Five Moments in 15 Ränge, abgestuft von „sauber“ bis „schmutzig“, aufgegliedert, um ableiten zu können, ob das durch den Kontakt gegebene unterschiedliche Kontaminationsrisiko einen Einfluss auf die Compliance hat.
Ergebnisse: Auf der neurologischen Bettenstation wurden für die Pflegekräfte 101,5 Indikationen/PT, für das ärztliche Personal 2,2 Indikationen/PT, auf der chirurgischen Bettenstation für die Pflegekräfte 146,8 und für das ärztliche Personal 4,7 Indikationen/PT ermittelt. Der Unterschied zwischen Pflegenden und ärztlichem Personal war signifikant (p=0,0001). Im Arbeitsalltag ergaben sich für Moment 3 (nach Kontakt mit potentiell infektiösem Material) und Moment 5 (nach Kontakt mit der unmittelbaren Patientenumgebung) die meisten Indikationen. Anhand der Anzahl der Indikationen ergab sich ein höherer Soll-Verbrauch an HDM mit 311 ml/PT für die neurologische bzw. 455 ml/PT für die chirurgische Station als der für Deutschland kalkulierte Richtwert von 120 ml HDM/PT.
Die Compliance betrug im Mittel aller Schichten und beider Berufsgruppen auf der neurologischen Station 50,7%, auf der chirurgischen Station 59,6 % (p=0,27). Die höchsten Compliance Raten zeigten sich in Moment 4 sowie auf den hohen Fulkerson-Rängen.
Diskussion: Ursache für die geringere Anzahl an Indikationen der HD bei Ärzt*innen im Vergleich zu Pflegekräften ist der seltenere Patientenkontakt des ärztlichen Personals auf peripheren Stationen. Die Anzahl der Indikationen für die HD waren beim Pflegepersonal ähnlich hoch wie von Scheithauer et al. (2009) auf einer internistischen Intensivstation beobachtet.
Die beobachtete Compliance ist auf beiden Stationen unbefriedigend, obwohl analoge Daten aus der Literatur bekannt sind (Pittet et al. 1999). Das zeigt auf, dass auch in Nichtrisikobereichen intensive Anstrengungen zur Verbesserung der Compliance unternommen werden müssen. Anhand der ermittelten Indikationen ist es künftig auf den analysierten Stationen möglich, anhand der von der Apotheke ermittelten Verbrauchsdaten die Compliance abzuschätzen und Interventionsprogramme zur Verbesserung der Compliance umzusetzen. Die unterschiedliche Anzahl sich ergebender Indikationen für die fünf Momente bietet die Möglichkeit, in zukünftigen Interventionsprogrammen verstärkt auf Schwachstellen einzugehen.
In der vorliegenden Arbeit wurde die mikrobiozide Wirksamkeit von Medihoney® 1:8 verdünnt im quantitativen Suspensionstest und unverdünnt im Prüfkörpertest im Vergleich zur Silberwundauflage Actisorb® silver 220 untersucht. Letztere wurde direkt mit den Prüforganismen inkubiert. Als Prüforganismen wurden P. aeruginosa, S. aureus, MRSA, VRE und C. albicans eingesetzt. Als Einwirkzeiten wurden die Sofortwirkung sowie die Wirksamkeit nach 1 h, 3h, 24 h und 48 h gewählt. Bei Actisorb® silver 220 wurde außerdem nach 30 min Einwirkzeit der RF berechnet, bei Medihoney® wurden statt 30 min 5 und 10 min als zusätzliche Einwirkzeit gewählt. Durch Medihoney® unverdünnt wurde bei allen Testorganismen ohne und mit Belastung durch 10% Rinderalbumin ein RF ≥3 lg-Stufen schon nach 1 h erreicht. Damit erfüllt Medihoney®, dessen Anwendung sich üblicherweise auf 48 h erstreckt, die Anforderungen an ein Wundantiseptikum mit hoher Sicherheitsreserve. Die 1:8 Verdünnung erreichte gegen die Testbakterien innerhalb von 24 h mit Eiweißbelastung die für ein Antiseptikum geforderte Wirksamkeit nicht ganz, wohl aber innerhalb 48 h. Damit ist selbst bei Verdünnung von aufgetragenem purem Medihoney® durch Wundsekret von einer ausreichenden Wirksamkeit auf Wunden auszugehen. Gegenüber C. albicans erreichte die Wirksamkeit bei Belastung nur etwa 1 log. Da Medihoney unverdünnt jedoch auch gegen C. albicans sicher wirksam ist und dieser Erreger nicht in vergleichbar hoher Kolonisationsdichte wie Bakterien auf Wunden auftritt, ist auch gegenüber diesem Erreger von einer ausreichenden Wirksamkeit auf Wunden auszugehen. Actisorb® silver 220 erreichte nur bei P. aeruginosa nach 24 h und 48 h ohne Belastung den ausreichenden RF von ≥3log-Stufen. Mit Belastung wurde die mikrobiozide Wirksamkeit praktisch aufgehoben. Damit wurde gezeigt, dass Medihoney® der Silberwundauflage an mikrobiozider Effektivität deutlich überlegen ist.
Ausgehend von der historischen Entwicklung der Händedesinfektion und der Händedesinfektionsmittelprüfung wurden drei Methoden der chirurgischen Händedesinfektion (waschen und desinfizieren, nur desinfizieren und desinfizieren und einbürsten des Desinfektionsmittels in den Nagelpfalz) und drei Mittel (Ethanol 79%, Propan-1-ol 60%, Propan-2-ol 60%) untersucht. Es erfolgte eine Bestimmung der Keimzahlreduktion im Sofort- und Langzeitwert sowie eine Analyse des Handschuhsaftes. Zum Vergleich wurde die undesinfizierte Hand geprüft. Des weiteren wurde das Vorkommen aerober Sporenbildner registriert und die Wirksamkeit der Waschung zur Sporenlastreduktion untersucht. In Vorversuchen wurden die Kolonisationsdichte auf dem Fingerendglied bestimmt, verschiedene nichtalkoholische Antiseptika charakterisiert und Faktoren, die mit der Händedesinfektion in Wechselwirken treten können, diskutiert. Die reine Alkoholanwendung und die reine Alkoholanwendung mit Einbürsten zeigten sich als mindestens genauso effektiv wie die Standardmethode bzw. waren ihr teilweise signifikant überlegen. Für die Desinfektionsmittel ergab sich, dass das bei der geprüften Konzentration von 60Vol% gering wirksame Propan-2-ol, aber auch der in seiner Wirksamkeit mit Propan-1-ol vergleichbare 79%ige Ethanol durch die Auslassung der Waschung und dem Einbürsten besonders gewannen. Bei den desinfizierten Händen fanden sich häufiger Sporenbildner als bei den undesinfizierten Händen. Die Alkoholkonzentration im Handschuhsaft war nach Desinfektion und 3 h Tragen 12fach höher als bei der undesinfizierten Hand. Mit der Waschung ließ sich an der artifiziell kontaminieren Hand eine signifikante Sporenlastreduktion erzielen. Als Resultat der Untersuchungen wird eine Veränderung der Standardmethode empfohlen. Waschung und Desinfektion sollten zeitlich und räumlich getrennt und bei hochaseptischen Eingriffen das Desinfektionsmittel in die Nagelfalze eingebürstet werden. Auf diese Weise soll die sporenlastsenkende Wirkung der Waschung mit der verbesserten Keimreduktion der Desinfektion ohne unmittelbar vorher durchgeführte Waschung verbunden werden. Unter der Annahme der Störung der Integrität der Epidermis unter dem Okklusionseffekt des Handschuhes und der gefundenen Alkoholkonzentration wird auf die Bedeutung der sorgfältigen Trocknung der Hand nach der Desinfektion hingewiesen.
Einfluss der Händehygiene in Verwaltungen auf das Infektionsgeschehen und ökonomische Auswirkungen
(2008)
Ziel der Arbeit war den Einfluss der Händedesinfektion auf die Erkrankungsrate und die Fehlzeiten von Erwerbspersonen in einem Setting außerhalb von Gesundheitseinrichtungen zu untersuchen. In Vorversuchen konnte bestätigt werden, dass Papier neben Kundenkontakt ein wichtiger Risikofaktor für die Übertragung pathogener Erreger ist. Es konnte sowohl die Rückgewinnung von Erregern von experimentell inokuliertem Papier als auch die Übertragung von Hand zu Papier zu Hand nachgewiesen werden. Die Datenerhebung erfolgte im Rahmen einer einjährigen prospektiven, kontrollierten, randomisierten Machbarkeitsstudie, an der 134 Mitarbeiter der öffentlichen Verwaltung teilnahmen. Die Testgruppe führte als Intervention mehrmals täglich die hygienische Händedesinfektion am Arbeitsplatz durch. Anhand monatlicher Befragungen wurden die durch Erkältungs- und Durchfallerkrankungen bedingten Symptomtage und Fehlzeiten erfasst. In der Testgruppe trat eine signifikante Reduktion sowohl bei den jährlichen Gesamtsymptomtagen (p = 0,01) als auch bei den Einzelsymptomen Schnupfen (p = 0,008), Fieber (p = 0,037) und Husten (p = 0,0024) ein. Der größte Einfluss der Händedesinfektion ergab sich in den Monaten mit der höchsten saisonalen Inzidenz Dezember, Januar, Februar, März. Es konnte ebenfalls ein Reduktion der Krankheitsepisoden (odds ratioGesamt_res = 1,28; odds ratioSchnupfen = 1,73; odds ratioHalsschmerzen = 1,13; odds ratioFieber = 1,31; odds ratioHusten = 1,30; odds ratioDurchfall = 4,01) belegt werden. In den Randomisierungsgruppen wurde die stärkste Reduktion der Krankheitsepisoden bei den respiratorischen Symptomen in der Gruppe mit seltenem Kundenkontakt und täglichem Umgang mit Archivgut (odds ratioGesamt_res(3,1) = 14,34) beobachtet, bei den gastrointestinalen Symptomen in der Gruppe mit häufigen Kundenkontakt und täglichem Umgang mit Archivgut (odds ratioDurchfall(1,1) = 14,63). Ökonomische Auswirkungen ergaben sich in erster Hinsicht aus dem Einfluss auf die Leistungsminderung beim Weiterarbeiten trotz vorhandener Krankheitssymptome und den damit einher gehenden „on-the-job“-Produktivitätsverlust. Durch die Studie wurde das Bewusstsein der Probanden für die Bedeutung der Händehygiene gestärkt. Sie stellt einen einfach umzusetzenden Ansatz für eine kosteneffiziente betriebliche Gesundheitsförderung dar.
Im heutigen Klinikalltag werden zur Behandlung chronischer Wunden Antiseptika und Antibiotika häufig kombiniert. Die vorliegende Arbeit hinterfragt diese Kombinationen, da sie oft ohne Wissen möglicher Wechselwirkungen verabreicht werden. Wir haben das Interaktionspotential der drei Antiseptika Octenidindihydrochlorid, Polihexanid und Chlorhexidindigluconat mit folgenden ß-Lactam-Antibiotika untersucht: Oxacillin, Ampicillin, Piperacillin + Tazobactam, Imipenem und Ceftazidim. In der Auswahl der Erreger haben wir uns auf die konzentriert, die statistisch besonders häufig in chronischen Wunden nachgewiesen werden: zwei S. aureus Stämme, ein MRSA-Stamm, zwei Enterococcus-, vier Pseudomonaden- und zwei E. coli-Stämme. In Vorversuchen haben wir mit der Mikroagardilutionsmethode die MHK’s der Erreger der verschiedenen Antiseptika auf den verschiedenen Agarsorten (Müller-Hinton-, Isosensitest-, CSA- und Blutagar) bestimmt. Orientierend an diesen Werten haben wir in den Hauptversuchen mittels Agardiffusions-Dilutions-Combitest das Interaktionspotential der oben genannten Antiinfektiva untersucht. Dazu haben wir Platten mit den Konzentrationen MHK, 1/8 MHK und 1/16 MHK gegossen. Bei der Auswertung wird deutlich, dass nicht alle Kombinationen bedenkenlos zusammengestellt werden sollten. In unseren Versuchen schneidet OCT am besten ab, hier vor allem die Kombination mit IMP 10. Auch PHMB weist gute Ergebnisse auf und nimmt eine Position zwischen OCT und CHX ein. CHX schneidet bei unseren Versuchen am schlechtesten ab und sollte sehr kritisch eingesetzt werden. Die Ergebnisse machen aber auch deutlich, dass es klare Unterschiede bezüglich der Erreger gibt.
Abstract
Antimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant‐associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H2O2 for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self‐assembled PHMB layer. Compared with an untreated control group, adsorbed PHMB produces no adverse effects on SaOs‐2 cells within 48 hr cell culture, but promotes the initial attachment and spreading of the osteoblasts within 15 min. Specimens were inoculated with slime‐producing bacteria to simulate a perioperative infection. Adsorbed PHMB reacts bactericidally against Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa after surface contact. Adhered SaOs‐2 cells differentiate and produce alkaline phosphatase and deposit calcium within 4 days in a mineralization medium on PHMB‐coated Ti6Al4V surfaces, which have been precontaminated with S. epidermidis. The presented procedures provide a simple method for generating biocompatibly and antimicrobially effective implant surfaces that may be clinically important.
Ziel dieser Arbeit war der Nachweis der antimikrobielle Wirksamkeit von oberflächlich, durch einfache chemische Verfahren immobilisiertem PHMB auf Ti6Al4V-Oberflächen gegenüber Gram-positiven und Gram-negativen Erregern mit Standardmethoden und methodischen Varianten.
Die Immobilisierung von PHMB auf Ti6Al4V-Oberflächen erfolgte entweder oxidativ durch die Behandlung der Prüfkörper mit 5 % H2O2 oder über eine alkalische Hydrolyse in 5 M NaOH-Lösung. Als Prüfmikroorganismen dienten die Gram-positiven Schleimbildner S. aureus (ATCC 29213/DSM 2569) und S. epidermidis (ATCC 35984/DSM 28319), als Gram-negativer Vertreter P. aeruginosa (ATCC 27853/DSM 1117). Die Biofilmbildungsintensitäten der eingesetzten Erreger wurden nach Anwendung der Kristallviolett-Färbemethode (Fletcher 1977) quantifiziert. Die Ermittlung der antimikrobiellen Wirksamkeit von PHMB-beschichteten Prüfkörpern erfolgte durch quantitative bzw. qualitative Methoden. Dafür wurden zwei Strategien verfolgt: (1) Herstellung des unmittelbaren Kontakts zwischen Mikroorganismen und antimikrobieller Oberfläche durch Verringerung des Flüssigkeitsvolumens des Kulturmediums mittels Vakuum- oder Wärmebehandlung; und (2) Untersuchung des Adhärenzverhaltens der Mikroorganismen nach 15 min und/oder 6 h Kontakt mit der PHMB-Beschichtung der Ti6Al4V-Prüfkörper. Die Etablierung eines ATP-Tests zur quantitativen Bestimmung der Bakterien war ebenfalls Bestandteil der Untersuchungen zur antimikrobiellen Wirksamkeit. Qualitativ erfolgte die Auswertung mit Hilfe von LIVE/DEAD-Färbungen und des CASO-Agar-Overlay-Tests. Die Validierung der effektiven mikrobioziden Wirksamkeit gegenüber S. epidermidis erfolgte in Co-Kultur-Versuchen mit den Osteoblasten-ähnlichen SaOs-2-Zellen.
Während die Kultivierung von S. aureus und P. aeruginosa im verwendeten Zellkulturmedium DMEM/F12 möglich war, tolerierte S. epidermidis das Medium nicht. Die Entwicklung eines Co-Kulturmediums, bestehend aus 10 % CASO-Bouillon und 90 % Zellkulturmedium, ermöglichte sowohl das Wachstum der Bakterienspecies als auch das der SaOs-2 Zellen, was eine wichtige Voraussetzung für weiterführende Co-Kulturen war. Die Produktion eines Biofilms konnte bei allen Erregern mittels Kristallviolett-Färbung nachgewiesen werden. Nach Herstellung des direkten Kontaktes zwischen den Prüfmikroorganismen und der antimikrobiellen Oberfläche durch Reduzierung des Flüssigkeitsvolumens der applizierten Bakteriensuspensionen, resultierten Reduktionsraten von 3 – 5 log10 für S. aureus und S. epidermidis. Der Gram-negative Erreger P. aeruginosa ist hingegen mit nur 0,5 – 1,5 log10-Stufen Reduktion für diese Methoden als ungeeignet einzustufen ist, da ein Absterben des Erregers aufgrund von Austrocknung nicht auszuschließen war. Die Adhärenz der eingesetzten Mikroorganismen nach 15 min Kontaktzeit und anschließender Inkubation bei 37 °C für 6 h, resultierte in Reduktionsraten von 4 – 5 log10 für S. aureus, 1 – 5 log10 für P. aeruginosa und 3 – 4 log10 für S. epidermidis. Mit PHMB beschichtete Ti6Al4V-Prüfkörper, die in einer Bakteriensuspension für 6 h unter dynamischen Bedingungen inkubiert wurden, zeigten nur Reduktionsraten von ca. 1 – 3 log10-Stufen gegenüber den Testbakterien. Nach 15 min Kontaktzeit auf einer kontaminierte Agar-Oberfläche und weiteren 6 h Inkubation bei 37 °C, konnten auf antimikrobiellen PHMB-Oberflächen Reduktionen von 1 – 2 log10-Stufen ermittelt werden. In angewandten Co-Kulturtests mit S. epidermidis und SaOs-2 Zellen konnte die antimikrobielle Wirksamkeit der PHMB-beschichteten Oberfläche bestätigt werden.
Die antimikrobiell wirksame PHMB-Schicht auf den eingesetzten Ti6Al4V-Prüfkörpern benötigt zur Abtötung von Erregern den direkten Kontakt zwischen der Oberfläche und den Prüfmikroorganismen, um wirksam zu sein. Zudem konnte ermittelt werden, dass PHMB ausschließlich auf der Oberseite der Prüfkörper immobilisiert werden konnte, was die Mikrobiozidie-Testung mit herkömmlichen Methoden erschwert.
Es konnte bestätigt werden, dass oberflächlich immobilisiertes PHMB auf Ti6Al4V-Prüfkörpern sowohl Gram-positive als auch Gram-negative Bakterien bei direktem Kontakt abtötet. Als am besten geeignet für die Testung dieser Oberfläche erwies sich die 6 h-Adhärenz-Methode, bei der nach 6 h oberflächlichem Kontakt quantitativ und qualitativ keine überlebenden Mikroorganismen nachgewiesen werden konnten.
In einer prospektiven, randomisierten, verblindeten, monozentrischen, offen kontrollierten Studie wurde die unter Anwendung einer CHD-haltigen Mundspüllösung auftretende Konzentrationsänderung von CHD im Speichel untersucht, die mit zunehmender Anwendungsdauer unmittelbar nach Spülung einen kontinuierlichen Konzentrationsanstieg von CHD zeigte. Im Verlauf von 12 Stunden nach Spülung wurde die Aufrechterhaltung konstanter Konzentrationen nachgewiesen. Es konnte statistisch signifikant der Nachweis erbracht werden, dass mit der Anwendung der Mundspüllösung in allgemein üblicher Dosierung auch messbare Konzentrationen und damit eine Belastung mit dem kanzerogenen p-CA, nicht aber mit p-CNB, im Speichel auftrat. Eine Resorption von CHD, p-CA oder p-CNB mit Nachweis in Serum und Urin konnte dagegen nicht nachgewiesen werden.
Untersuchung zur Wirkung von kaltem Atmosphärendruckplasma über die Oxidation von Thiolgruppen
(2022)
Redox signaling-Prozesse innerhalb und zwischen Zellen spielen eine Rolle in
verschiedenen physiologischen und pathologischen Prozessen, wobei zelluläre
Thiolgruppen als wichtige Signalübermittler identifiziert wurden. Durch Behandlung der
Aminosäure Cystein mit kaltem Atmosphärendruckplasma werden solche
Thiolgruppen oxidiert und verschiedene Verbindungen erzeugt. Diese Arbeit sollte
klären, ob so die Erzeugung von stabilen reaktiven Spezies möglich ist, die einen
biologischen Effekt haben. Dazu wurden Pufferlösungen, die Cystein enthielten, mit
einem Argon-Plasmajet (kINPen 09) mit Sauerstoffzumischung behandelt und auf
kultivierte menschliche Keratinozyten der HaCaT-Zellinie übertragen. Zellproliferation,
Migrationsaktivität, Metabolismus, Viabilität und intrazellulärer Redoxzustand wurden
untersucht.
Plasmabehandelte Flüssigkeiten mit Cysteinkonzentrationen von 2 mmol/l zeigten
keinen Einfluss auf das Zellverhalten im Vergleich zu behandeltem Puffer ohne
Cystein. Erhöhte Cysteinkonzentrationen von 100 mmol/l verringerten bei langen
Plasmabehandlungszeiten von 5 min beziehungsweise 10 min die Proliferation,
Migration, Laktatsekretion und Viabilität. Für kürzere Behandlungszeiten von 1 min und
2,5 min wurden Hinweise auf eine erhöhte metabolische Aktivität gefunden. GSSGSpiegel
in den Zellen wurden stabilisiert und intrazelluläre ROS reduziert. Diese
Effekte könnten auf generierte bioaktive Substanzen wie oxidierte Disulfide
zurückzuführen sein, die längerfristig zu Energiemangel führen. Ein möglicher
Vermittler ist Cystein-S-sulfonat, welches als NMDA-Rezeptoragonist bekannt ist.
Zudem könnte auch die Aktivierung des XC-Antiporters mit Folgen für den
intrazellulären Redoxzustand zu den kurzfristigen Effekten beigetragen haben.
Durch plasmabehandelte Cysteinlösung konnten biologische Effekte, teilweise im
Sinne einer Hormesis, nachgewiesen werden. Die Ergebnisse zeigten eine
zytotoxische Wirkung nach langer Plasmabehandlung der Cysteinlösung, während für
kürzere Zeiten auch aktivierende Effekte deutlich wurden. Somit scheint die gezielte
Erzeugung stabiler reaktiver Spezies als neuer Ansatzpunkt der Plasmaanwendung
möglich.