Refine
Document Type
- Article (6)
Language
- English (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
- - (3)
- acupuncture (2)
- Aspiration (1)
- Bleeding (1)
- Gasdermin D (1)
- Jet ventilation (1)
- Tracheal surgery (1)
- auricular acupuncture (1)
- biomarker (1)
- breastfeeding (1)
Institute
Publisher
- MDPI (3)
- American Medical Association (1)
- S. Karger AG (1)
- SAGE Publications (1)
Background: To determine the suitability of different superimposed high-frequency jet ventilation (SHFJV) application methods during tracheal bleeding. Objective: To determine the effect of SHFJV on the aspiration of blood during tracheal bleeding. Methods: A test lung was ventilated using SHFJV via a rigid endoscope, a jet laryngoscope and a 4-lumen jet catheter. Packed red blood cells (PRBCs) were injected into the artificial trachea caudally to the rigid endoscope and jet laryngoscope ventilation, and both caudally and cranially during ventilation via the 4-lumen jet catheter, and the migration of PRBCs during ventilation was studied using continuous video recording. Results: Migration of blood into the lower respiratory tract did not occur during SHFJV via the rigid endoscope and jet laryngoscope and via the 4-lumen jet catheter with the bleeding caudal to ventilation source. If the bleeding was cranial to the 4-lumen jet catheter ventilation, migration of blood into the lower respiratory tract was seen when reflux of blood reached the entrainment area. From this area, blood is transported within the jet stream into the lower respiratory tract. Conclusions: SHFJV protects the lower respiratory tract from blood aspiration in case of tracheal bleeding. During SHFJV via the 4-lumen jet catheter, aspiration of blood only occurs if bleeding is localized cranial to the 4-lumen jet catheter ventilation. In case of heavy tracheal bleeding, the jet sources should be positioned cranial to the site of bleeding.
Introduction:
Breastfeeding is a recognized preferred method of infant feeding; however, for many women, difficulties in breastfeeding result in termination before the recommended period of time. Acupuncture is suggested to be a promising option to treat lactation insufficiency and enhance the production of maternal milk.
Main Issue:
We have reported the case of a woman with lactation insufficiency due to Caesarean section and congenital unilateral invaginated nipple. Milk production started on the 3rd day following delivery. The newborn was not provided with any food or fluids other than mother’s milk. At 5 days of life, the newborn required long feeding periods and lost 4% of his birth weight, with the participant reporting lactation insufficiency described by the perception of inadequate milk production.
Management:
Despite the implementation of conventional measures to improve lactation, the difficulties in breastfeeding persisted. Acupuncture was tried on Day 6 of life, and enhanced milk production was observed, which could be measured as the volume of residual milk extracted using the breast pump each time after the newborn achieved satiety. After acupuncture treatment there was an augmentation of maternal milk production from both breasts and successful lactation.
Conclusion:
This case study provides information that might be useful for prospective investigation of acupuncture’s efficacy in women with lactation insufficiency.
Effectiveness of Acupuncture for Pain Control After Cesarean Delivery: A Randomized Clinical Trial
(2022)
Importance: A pharmacological approach to pain control after cesarean delivery is often insufficient on its own. Acupuncture is a promising method for mitigating postoperative pain and reducing postoperative opioid requirements.
Objective: To evaluate the efficacy and effectiveness of acupuncture as an adjunctive therapy for pain control after cesarean delivery, compared with a placebo intervention and standard care alone.
Design, Setting, and Participants: This single-center, placebo-controlled, patient- and assessor-blinded randomized clinical trial was conducted from January 13, 2015, to June 27, 2018, at a tertiary university hospital in Greifswald, Germany. Participants were women who were scheduled for elective cesarean delivery under spinal anesthesia and were randomized to either the acupuncture group (n = 60) or placebo group (n = 60). Another 60 consecutive patients who met the eligibility criteria and received the standard postoperative analgesia were selected to form a nonrandomized standard care group. The intention-to-treat analysis was performed from August 19, 2019, to September 13, 2019.
Interventions: In addition to standard pain treatment, each patient in the acupuncture group received auricular and body acupuncture with indwelling intradermal needles, whereas patients in the placebo group were treated with nonpenetrating placebo needles.
Main Outcomes and Measures: The primary outcome was pain intensity on movement, which was measured using an 11-item verbal rating scale. Secondary outcomes were analgesia-related adverse effects, analgesics consumption, time to mobilization and Foley catheter removal, quality of patient blinding to randomization, and patient satisfaction with treatment of pain.
Results: A total of 180 female patients (mean [SD] age, 31 [5] years) were included in the intention-to-treat analysis. The mean pain intensity on movement in the acupuncture group on the first postoperative day was lower than in the placebo group (4.7 [1.8] vs 6.0 [2.0] points; Cohen d, 0.73; 95% CI, 0.31-1.01; P = .001) and the standard care group (6.3 [1.3] points; Cohen d, 1.01; 95% CI, 0.63-1.40; P < .001). On the first postoperative day, 59 patients (98%) in the acupuncture group were fully mobilized vs 49 patients (83%) in the placebo group (relative risk [RR], 1.18; 95% CI, 1.06-1.33; P = .01) and 35 patients (58%) in the standard care group (RR, 1.69; 95% CI, 1.36-2.09; P < .001). The Foley catheter was removed in a total of 57 patients (93%) from the acupuncture group vs 43 patients (72%) from the placebo group (RR, 1.33; 95% CI, 1.12-1.57; P = .003) and 42 patients (70%) from the standard care group (RR, 1.37; 95% CI, 1.14-1.62; P = .002). Other parameters were comparable across the 3 study groups.
Conclusions and Relevance: Results of this trial showed that acupuncture was safe and effective in reducing pain and accelerating mobilization of patients after cesarean delivery. With consideration for personnel and time expenditures, acupuncture can be recommended as routine, supplemental therapy for pain control in patients after elective cesarean delivery.
Advances in spine surgery enable technically safe interventions in older patients with disabling spine disease, yet postoperative delirium (POD) poses a serious risk for postoperative recovery. This study investigates biomarkers of pro-neuroinflammatory states that may help objectively define the pre-operative risk for POD. This study enrolled patients aged ≥60 scheduled for elective spine surgery under general anesthesia. Biomarkers for a pro-neuroinflammatory state included S100 calcium-binding protein β (S100β), brain-derived neurotrophic factor (BDNF), Gasdermin D, and the soluble ectodomain of the triggering receptor expressed on myeloid cells 2 (sTREM2). Postoperative changes of Interleukin-6 (IL-6), Interleukin-1β (IL-1β), and C-reactive protein (CRP) were assessed as markers of systemic inflammation preoperatively, intraoperatively, and early postoperatively (up to 48 h). Patients with POD (n = 19, 75.7 ± 5.8 years) had higher pre-operative levels of sTREM2 (128.2 ± 69.4 pg/mL vs. 97.2 ± 52.0 pg/mL, p = 0.049) and Gasdermin D (2.9 ± 1.6 pg/mL vs. 2.1 ± 1.4 pg/mL, p = 0.29) than those without POD (n = 25, 75.6 ± 5.1 years). STREM2 was additionally a predictor for POD (OR = 1.01/(pg/mL) [1.00–1.03], p = 0.05), moderated by IL-6 (Wald-χ2 = 4.06, p = 0.04). Patients with POD additionally showed a significant increase in IL-6, IL-1β, and S100β levels on the first postoperative day. This study identified higher levels of sTREM2 and Gasdermin D as potential markers of a pro-neuroinflammatory state that predisposes to the development of POD. Future studies should confirm these results in a larger cohort and determine their potential as an objective biomarker to inform delirium prevention strategies.