Volltext-Downloads (blau) und Frontdoor-Views (grau)
  • search hit 5 of 8
Back to Result List

Bitte verwenden Sie diesen Link, wenn Sie dieses Dokument zitieren oder verlinken wollen: https://nbn-resolving.org/urn:nbn:de:gbv:9-opus-104571

In vitro response of THP-1 derived macrophages to antimicrobially effective PHMB-coated Ti6Al4V alloy implant material with and without contamination with S. epidermidis and P. aeruginosa

  • Aim Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed. Methods THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted. Results No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden. Conclusion Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.

Download full text files

Export metadata

Additional Services

Search Google Scholar

Statistics

frontdoor_oas
Metadaten
Author: Paula Zwicker, Thomas Schmidt, Melanie Hornschuh, Holger N. LodeORCiD, Axel KramerORCiD, Gerald Müller
URN:urn:nbn:de:gbv:9-opus-104571
DOI:https://doi.org/10.1186/s40824-021-00247-1
ISSN:2055-7124
Parent Title (English):Biomaterials Research
Publisher:BioMed Central (BMC)
Place of publication:London
Document Type:Article
Language:English
Date of first Publication:2022/01/09
Release Date:2024/01/16
Tag:Cytokine secretion; Implant surface; Poly (hexamethylene biguanide) hydrochloride (PHMB); THP-1 macrophages; Ti6Al4V alloy
Volume:26
Article Number:1
Page Number:13
Faculties:Universitätsmedizin / Institut für Hygiene und Umweltmedizin
Collections:Artikel aus DFG-gefördertem Publikationsfonds
Licence (German):License LogoCreative Commons - Namensnennung