Mass spectrometry of atomic ions produced by in-trap decay of short-lived nuclides
- The triple-trap mass spectrometer ISOLTRAP at ISOLDE/CERN has demonstrated the feasibility of mass spectrometry of in-trap-decay product ions. This novel technique gives access to radionuclides, which are not produced directly at ISOL-type radioactive ion beam facilities. As a proof of principle, the in-trap decay of 37K+ has been investigated in a Penning trap filled with helium buffer gas. The half-life of the mother nuclide was confirmed and the recoiling 37Ar+ daughter ion was contained within the trap. The ions of either the mother or the daughter nuclide were transferred to a precision Penning trap, where their mass was determined.
Author: | A Herlert, D Beck, K Blaum, F Carrel, P Delahaye, S George, C Guénaut, F Herfurth, A Kellerbauer, H-J Kluge, D Lunney, M Mukherjee, Lutz SchweikhardORCiD, C Yazidjian |
---|---|
URN: | urn:nbn:de:gbv:9-opus-59638 |
DOI: | https://doi.org/10.1088/1367-2630/7/1/044 |
ISSN: | 1367-2630 |
Parent Title (English): | New Journal of Physics |
Document Type: | Article |
Language: | English |
Date of first Publication: | 2005/02/08 |
Release Date: | 2022/11/30 |
GND Keyword: | - |
Volume: | 7 |
Issue: | 1 |
First Page: | 44 |
Last Page: | 44 |