Refine
Document Type
- Article (2)
Language
- English (2)
Has Fulltext
- yes (2) (remove)
Is part of the Bibliography
- no (2)
Keywords
Institute
Publisher
- BioMed Central (BMC) (2) (remove)
Aim
Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed.
Methods
THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted.
Results
No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden.
Conclusion
Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.
Objectives
Oral mucositis caused by intensive cancer chemotherapy or radiotherapy frequently results in pronounced damage of the oral mucosa leading to painful oral hygiene. To support oral care, antimicrobial effective mouth rinses may be used. Thus, the efficacy of a hypochlorite-based mouth rinse (Granudacyn®), assumed to be highly biocompatible because of the compounds being part of the natural pathogen defense, as possible antiseptic agent in case of oral mucositis was compared to that of an octenidine based antiseptic mouth rinse (Octenidol® md).
Materials and methods
The study was conducted as monocentric, controlled, randomized, blind cross over comparative study on 20 volunteers. As a proof of principle, we performed the study on orally healthy subjects and not cancer patients. The efficacy was determined as reduction of colony forming units (cfu) on buccal mucosa as well as in saliva. After mouth rinsing for 30 s, samples were taken after 1 min, 15 min, 30 and 60 min. The lg-reduction was calculated as difference between lg-values of cfu pre- and post-treatment.
Results
Both antiseptic mouth rinses induced a significant reduction of cfu on buccal mucosa and in saliva 1 min after mouth rinsing. The effect persisted up to 60 min. The octenidine based rinse was significantly superior to the hypochlorite-based rinse up to the last sample 60 min after rinsing. However, the known cytotoxicity of octenidine argues against its application.
Conclusion
Within the limits of this study, due to its antiseptic efficacy, the hypochlorite-based rinse Granudacyn® can be regarded appropriate to support the oral hygiene in patients with a sensitive oral mucosa during an aggressive cancer chemotherapy and radiation treatment in case of oral mucositis.