Refine
Year of publication
Document Type
- Article (24)
Language
- English (24)
Has Fulltext
- yes (24)
Is part of the Bibliography
- no (24)
Keywords
- - (24) (remove)
Institute
- Institut für Hygiene und Umweltmedizin (24) (remove)
Publisher
- MDPI (12)
- S. Karger AG (10)
- Frontiers Media S.A. (1)
- IOP Publishing (1)
Unlike the native surface of the implant material (Ti6Al4V), oxidation with H2O2 leads to increased binding of the effective antimicrobial agent poly(hexamethylene) biguanide [PHMB]. However, treating with NaOH instead results in an even higher PHMB mass coverage. After oxidation with H2O2, strong differences in the PHMB adsorption capability between polished and corundum-blasted surfaces appear, indicating a roughness dependence. After NaOH treatment, no such effect was observed. The wetting properties of specimens treated with either H2O2 or NaOH prior to PHMB exposure clearly varied. To unravel the nature of this interaction, widespread in silico and in vitro experiments were performed. Methods: By X-ray photoelectron spectroscopy, scanning electron microscopy, water contact angle measurements and MD simulations, we characterized the interplay between the polycationic antimicrobial agent and the implant surface. A theoretical model for PHMB micelles is tested for its wetting properties and compared to carbon contaminated TiO2. In addition, quantitation of anionic functional group equivalents, the binding properties of PHMB with blocked amino end-group, and the ability to bind chlorhexidine digluconate (CHG) were investigated. Ultimately, the capability of osteoblasts to build calcium apatite, and the activity of alkaline phosphatase on PHMB coated specimens, were determined. Results: Simulated water contact angles on carbon contaminated TiO2 surfaces and PHMB micelle models reveal little influence of PHMB on the wetting properties and point out the major influence of remaining and recovering contamination from ambient air. Testing PHMB adsorption beyond the critical micelle concentration and subsequent staining reveals an island-like pattern with H2O2 as compared to an evenly modified surface with NaOH. Both CHG and PHMB, with blocked amino end groups, were adsorbed on the treated surfaces, thus negating the significant influence of PHMB’s terminal groups. The ability of osteoblasts to produce calcium apatite and alkaline phosphatase is not negatively impaired for PHMB mass coverages up to 8 μg/specimen. Conclusion: Differences in PHMB adsorption are triggered by the number of anionic groups and carbon contaminants, both of which depend on the specimen pre-treatment. With more PHMB covering, the implant surface is protected against the capture of new contamination from the ambient air, thus building a robust antimicrobial and biocompatible surface coating.
AbstractPlasma medicine refers to the application of nonequilibrium plasmas at approximately body temperature, for therapeutic purposes. Nonequilibrium plasmas are weakly ionized gases which contain charged and neutral species and electric fields, and emit radiation, particularly in the visible and ultraviolet range. Medically-relevant cold atmospheric pressure plasma (CAP) sources and devices are usually dielectric barrier discharges and nonequilibrium atmospheric pressure plasma jets. Plasma diagnostic methods and modelling approaches are used to characterize the densities and fluxes of active plasma species and their interaction with surrounding matter. In addition to the direct application of plasma onto living tissue, the treatment of liquids like water or physiological saline by a CAP source is performed in order to study specific biological activities. A basic understanding of the interaction between plasma and liquids and bio-interfaces is essential to follow biological plasma effects. Charged species, metastable species, and other atomic and molecular reactive species first produced in the main plasma ignition are transported to the discharge afterglow to finally be exposed to the biological targets. Contact with these liquid-dominated bio-interfaces generates other secondary reactive oxygen and nitrogen species (ROS, RNS). Both ROS and RNS possess strong oxidative properties and can trigger redox-related signalling pathways in cells and tissue, leading to various impacts of therapeutic relevance. Dependent on the intensity of plasma exposure, redox balance in cells can be influenced in a way that oxidative eustress leads to stimulation of cellular processes or oxidative distress leads to cell death. Currently, clinical CAP application is realized mainly in wound healing. The use of plasma in cancer treatment (i.e. plasma oncology) is a currently emerging field of research. Future perspectives and challenges in plasma medicine are mainly directed towards the control and optimization of CAP devices, to broaden and establish its medical applications, and to open up new plasma-based therapies in medicine.
Background: Annual transfusion rates in many European countries range between 25 and 35 red blood cell concentrates (RBCs)/1,000 population.It is unclear why transfusion rates in Germany are considerably higher (approx. 50–55 RBCs/1,000 population). Methods: We assessed the characteristics of transfusion recipients at all hospitals of the German federal state Mecklenburg-Western Pomerania during a 10-year longitudinal study. Results: Although 75% of patients received ≤4 RBCs/patient in 2015 (1 RBC: 11.3%; 2 RBCs: 42.6%; 3 RBCs: 6.3%; 4 RBCs: 15.0%), the mean transfusion index was 4.6 RBCs due to a minority of patients with a high transfusion demand. Two thirds of all RBCs were transfused to only 25% of RBC recipients. Consistently, male patients received a higher number of RBCs (2005: 54.2%; 2015: 56.8%) and had a higher mean transfusion index than female patients (mean 5.1 ± 7.2; median 2; inter-quartile range [IQR] 2–4 vs. mean 4.0 ± 5.8; median 2; IQR 2–4). The absolute transfusion demand decreased between 2005 and 2015 by 13.5% due to a composite of active reduction (clinical practice change) and population decline in the 65- to 75-year age group (lower birth rate cohort 1940–1950); however, with major differences between hospitals (range from –61.0 to +41.4%). Conclusion: Transfusion demand in a population could largely be driven by patients with high transfusion demand. Different treatment practices in this group of patients probably add to the major differences in transfusion demand per 1,000 individuals between countries. The available data cannot prove this hypothesis. Implementation of a diagnosis-related group-based monitoring system is urgently needed to allow informative monitoring on the population level and meaningful comparisons between transfusion practices.
Multiple evidence in animal models and in humans suggest a beneficial role of cold physical
plasma in wound treatment. Yet, risk assessment studies are important to further foster therapeutic
advancement and acceptance of cold plasma in clinics. Accordingly, we investigated the long-term
side effects of repetitive plasma treatment over 14 consecutive days in a rodent full-thickness ear
wound model. Subsequently, animals were housed for 350 days and sacrificed thereafter. In blood,
systemic changes of the pro-inflammatory cytokines interleukin 1β and tumor necrosis factor α
were absent. Similarly, tumor marker levels of α-fetoprotein and calcitonin remained unchanged.
Using quantitative PCR, the expression levels of several cytokines and tumor markers in liver,
lung, and skin were found to be similar in the control and treatment group as well. Likewise,
histological and immunohistochemical analysis failed to detect abnormal morphological changes
and the presence of tumor markers such as carcinoembryonic antigen, α-fetoprotein, or the neighbor
of Punc 11. Absence of neoplastic lesions was confirmed by non-invasive imaging methods such as
anatomical magnetic resonance imaging and positron emission tomography-computed tomography.
Our results suggest that the beneficial effects of cold plasma in wound healing come without apparent
side effects including tumor formation or chronic inflammation.
The objective of the present investigation was to examine the residual antimicrobial activity after a topical exposure of reconstructed human epidermis (RHE) to equimolar solutions of either chlorhexidine digluconate (CHG, 0.144% w/v) or octenidine dihydrochloride (OCT, 0.1% w/v) for 15 min. RHE-associated antiseptic agents were more effective on Staphylococcus aureus than on Pseudomonas aeruginosa. S. aureus was not detected after 24 h of contact, which demonstrated a microbicidal efficacy of greater than 5-log<sub>10</sub> reduction. In contrast, P. aeruginosa was reduced by approximately 2 log<sub>10</sub> at the same incubation time, which parallels the growth of the initial inoculum. This result could be interpreted either as a microbiostatic effect or as an adherence of P. aeruginosa to a low positively charged surface. Small amounts of CHG and OCT can penetrate the stratum corneum. Using these antiseptic agents, the viability of keratinocytes was reduced to 65-75% of that of the untreated RHE control following 24 h incubation in the presence of test microorganisms. With consideration of antimicrobial activity and cytotoxic effect, OCT corresponds better to a biocompatible antiseptic agent than CHG.
Because of its antimicrobial properties, nonthermal plasma could serve as an alternative to chemical antisepsis in wound treatment. Therefore, this study investigated the inactivation of biofilm-embedded Pseudomonas aeruginosa SG81 by a surface barrier-discharged (SBD) plasma for 30, 60, 150 and 300 s. In order to optimize the efficacy of the plasma, different carrier gases (argon, argon admixed with 1% oxygen, and argon with increased humidity up to approx. 80%) were tested and compared against 0.1% chlorhexidine digluconate (CHG) exposure for 600 s. The antimicrobial efficacy was determined by calculating the difference between the numbers of colony-forming units (CFU) of treated and untreated biofilms. Living bacteria were distinguished from dead by fluorescent staining and confocal laser scanning microscopy. Both SBD plasmas and CHG showed significant antimicrobial effects compared to the untreated control. However, plasma treatment led to a higher antimicrobial reduction (argon plasma 4.9 log<sub>10</sub> CFU/cm<sup>2</sup>, argon with admixed oxygen 3 log<sub>10</sub> CFU/cm<sup>2</sup>, and with increased gas humidity 2.7 log<sub>10</sub> CFU/cm<sup>2</sup> after 300 s) compared to CHG. In conclusion, SBD plasma is suitable as an alternative to CHG for inactivation of Pseudomonas aeruginosa embedded in biofilm. Further development of SBD plasma sources and research on the role of carrier gases and humidity may allow their clinical application for wound management in the future.
Wound healing disorders frequently occur due to biofilm formation on wound surfaces requiring conscientious wound hygiene. Often, the application of conventional liquid antiseptics is not sufficient and sustainable as (1) the borders and the surrounding of chronic wounds frequently consist of sclerotic skin, impeding an effectual penetration of these products, and (2) the hair follicles representing the reservoir for bacterial recolonization of skin surfaces are not affected. Recently, it has been reported that tissue-tolerable plasma (TTP), which is used at a temperature range between 35 and 45°C, likewise has disinfecting properties. In the present study, the effectivity of TTP and a standard liquid antiseptic was compared in vitro on porcine skin. The results revealed that TTP was able to reduce the bacterial load by 94%, although the application of the liquid antiseptic remained superior as it reduced the bacteria by almost 99%. For in vivo application, however, TTP offers several advantages. On the one hand, TTP enables the treatment of sclerotic skin as well, and on the other hand, a sustainable disinfection can be realized as, obviously, also the follicular reservoir is affected by TTP.