Refine
Document Type
- Article (6)
Language
- English (6)
Has Fulltext
- yes (6)
Is part of the Bibliography
- no (6)
Keywords
- Biomechanics (1)
- Cell biophysics (1)
- Cell cultures (1)
- Cell mechanics (1)
- Cell processes and subcellular processes (1)
- Cells (1)
- Dispersion function (1)
- Dust acoustic waves (1)
- Femtosecond lasers (1)
- Finite-element analysis (1)
Institute
- Institut für Physik (6) (remove)
Publisher
- AIP Publishing (6) (remove)
We investigate local THz field generation using spintronic THz emitters to enhance the resolution for micrometer-sized imaging. Far-field imaging with wavelengths above 100 µm limits the resolution to this order of magnitude. By using optical laser pulses as a pump, THz field generation can be confined to the area of laser beam focusing. The divergence of the generated THz beam due to laser beam focusing requires the imaged object to be close to the generation spot at a distance below the THz field wavelength. We generate THz-radiation by fs-laser pulses in CoFeB/Pt heterostructures, based on spin currents, and detect them by commercial low-temperature grown-GaAs (LT-GaAs) Auston switches. The spatial resolution of THz radiation is determined by applying a 2D scanning technique with motorized stages allowing step sizes in the sub-micrometer range. Within the near-field limit, we achieve spatial resolution in the dimensions of the laser spot size on the micrometer scale. For this purpose, a gold test pattern is evaporated on the spintronic emitter separated by a 300 nm SiO2 spacer layer. Moving these structures with respect to the femtosecond laser spot, which generates THz radiation, allows for resolution determination. The knife-edge method yields a full-width half-maximum beam diameter of 4.9 +- 0.4 µm at 1 THz. The possibility to deposit spintronic emitter heterostructures on simple glass substrates makes them attractive candidates for near-field imaging in many imaging applications.
In our study, we determine the alignment of magnetic domains in a CoFeB layer using THz radiation. We generate THz pulses by fs laser pulses in magnetized CoFeB/Pt heterostructures based on spin currents. An LT-GaAs Auston switch detects the radiation phase sensitively and allows us to determine the magnetization alignment. Our scanning technique with motorized stages, with step sizes in the sub-micrometer range, allows us to image two dimensional magnetic structures. Theoretically, the resolution is restricted to half of the wavelength if focusing optics in the far-field limit are used. By applying near-field imaging, the spatial resolution is enhanced to the single digit micrometer range. For this purpose, spintronic emitters in diverse geometric shapes, e.g., circles, triangles, squares, and sizes are prepared to observe the formation of magnetization patterns. The alignment of the emitted THz radiation can be influenced by applying unidirectional external magnetic fields. We demonstrate how magnetic domains with opposite alignment and different shapes divided by domain walls are created by demagnetizing the patterns using minor loops and imaged using phase sensitive THz radiation detection. For analysis, the data are compared to Kerr microscope images. The possibility of combining this method with THz range spectroscopic information of magnetic texture or antiferromagnets in direct vicinity to the spintronic emitter makes this detection method interesting for a much wider range of applications probing THz excitation in spin systems with high resolution beyond the Abbe diffraction limit, limited solely by the laser excitation area.
Mechanical properties have been proven to be a pivotal parameter to enhance our understanding of living systems. While research during the last decades focused on cells and tissues, little is known about the role of organelle mechanics in cell function. Here, mitochondria are of specific interest due to their involvement in numerous physiological and pathological processes, e.g., in the production and homeostasis of reactive oxygen species (ROS). Using real-time fluorescence and deformability cytometry, we present a microfluidic technology that is capable to determine the mechanical properties of individual mitochondria at a throughput exceeding 100 organelles per second. Our data on several thousands of viable mitochondria isolated from rat C6 glial cells yield a homogenous population with a median deformation that scales with the applied hydrodynamic stress. In two proof-of-principle studies, we investigated the impact of exogenously and endogenously produced ROS on mitochondria mechanics. Exposing C6 cells to hydrogen peroxide (H2O2) triggers superoxide production and leads to a reduction in mitochondria size while deformation is increased. In a second study, we focused on the knockout of tafazzin, which has been associated with impaired remodeling of the mitochondrial membrane and elevated levels of ROS. Interestingly, our results reveal the same mechanical alterations as observed after the exposure to H2O2, which points to a unified biophysical mechanism of how mitochondria respond to the presence of oxidative stress. In summary, we introduce high-throughput mechanical phenotyping into the field of organelle biology with potential applications for understanding sub-cellular dynamics that have not been accessible before.
Properties of self-excited dust acoustic waves under the influence of active compression of the dust particle system were experimentally studied in the laboratory and under microgravity conditions (parabolic flight). Ground based laboratory experiments clearly show that wave properties can be manipulated by changing the discharge volume, its aspect ratio, and thus the dust particle density. Complementary experiments under microgravity conditions, performed to exclude the effects of gravity inflicted sedimentation and anisotropic behavior, were less conclusive due to residual fluctuations in the planes acceleration indicating the need for a better microgravity environment. A theoretical model, using plasma parameters obtained from particle-in-cell simulations as input, supports the experimental findings. It shows that the waves can be described as a new observation of the dust acoustic mode, which demonstrates their generic character.
Copper tungsten oxide films are deposited with the help of reactive high power impulse magnetron sputtering (HiPIMS) in an argon/oxygen gas mixture. Two magnetrons, one equipped with a tungsten target and the other with a copper target, are employed. The HiPIMS discharge is operated with a repetition frequency of f=100 Hz. Pulse widths of 100 and 20 µs separated by 25 µs are chosen for the tungsten and copper target, respectively. Films deposited on two different glass substrates [soda lime glass and fluorine doped tin oxide (FTO) coated glass] are characterized by energy dispersive x-ray spectroscopy, x-ray photoelectron spectroscopy, x-ray diffraction, Raman spectroscopy, and ellipsometry. Photoelectrochemical activity was investigated by linear voltammetry. The composition and crystal structure of as-deposited and annealed films are found to depend on the deposition conditions. Annealed films deposited on FTO glass are composed of WO3 and CuWO4 or Cu2WO4 crystal phases. Films deposited on soda lime glass are subject to sodium diffusion into the films during annealing and the formation of Na2W2O7 and Na2W4O13 phases.
The capability to parameterize shapes is of essential importance in biomechanics to identify cells, to track their motion, and to quantify deformation. While various shape descriptors have already been investigated to study the morphology and migration of adherent cells, little is known of how the mathematical definition of a contour impacts the outcome of rheological experiments on cells in suspension. In microfluidic systems, hydrodynamic stress distributions induce time-dependent cell deformation that needs to be quantified to determine viscoelastic properties. Here, we compared nine different shape descriptors to characterize the deformation of suspended cells in an extensional as well as shear flow using dynamic real-time deformability cytometry. While stress relaxation depends on the amplitude and duration of stress, our results demonstrate that steady-state deformation can be predicted from single cell traces even for translocation times shorter than their characteristic time. Implementing an analytical simulation, performing experiments, and testing various data analysis strategies, we compared single cell and ensemble studies to address the question of computational costs vs experimental accuracy. Results indicate that high-throughput viscoelastic measurements of cells in suspension can be performed on an ensemble scale as long as the characteristic time matches the dimensions of the microfluidic system. Finally, we introduced a score to evaluate the shape descriptor-dependent effect size for cell deformation after cytoskeletal modifications. We provide evidence that single cell analysis in an extensional flow provides the highest sensitivity independent of shape parametrization, while inverse Haralick's circularity is mostly applicable to study cells in shear flow.