Refine
Document Type
- Article (1)
- Doctoral Thesis (1)
Language
- English (2)
Has Fulltext
- yes (2)
Is part of the Bibliography
- no (2)
Keywords
- Denture (1)
- Immediate dental implant loading (1)
- Mini-implant (1)
- Partial (1)
- Plaque (1)
- Randomized controlled trial (1)
- Removable (1)
- Reproduzierbarkeit (1)
- Resonance frequency analysis (1)
- Survival rate (1)
Institute
Publisher
- Springer Nature (1)
Objectives
Stability values of mini-implants (MIs) are ambiguous. Survival data for MIs as supplementary abutments in reduced dentitions are not available. The aim of this explorative research was to estimate the 3-year stability and survival of strategic MIs after immediate and delayed loading by existing removable partial dentures (RPDs).
Material and methods
In a university and three dental practices, patients with unfavorable tooth distributions received supplementary MIs with diameters of 1.8, 2.1, and 2.4 mm. The participants were randomly allocated to group A (if the insertion torque ≥ 35 Ncm: immediate loading by housings; otherwise, immediate loading by RPD soft relining was performed) or delayed loading group B. Periotest values (PTVs) and resonance frequency analysis (RFA) values were longitudinally compared using mixed models.
Results
A total of 112 maxillary and 120 mandibular MIs were placed under 79 RPDs (31 maxillae). The 1st and 3rd quartile of the PTVs ranged between 1.7 and 7.8, and the RFA values ranged between 30 and 46 with nonrelevant group differences. The 3-year survival rates were 92% in group A versus 95% in group B and 99% in the mandible (one failure) versus 87% in the maxilla (eleven failures among four participants).
Conclusions
Within the limitations of explorative analyses, there were no relevant differences between immediate and delayed loading regarding survival or stability of strategic MIs.
Clinical relevance
The stability values for MIs are lower than for conventional implants. The MI failure rate in the maxilla is higher than in the mandible with cluster failure participants.
Clinical trial registration
German Clinical Trials Register (Deutsches Register Klinischer Studien, DRKS-ID: DRKS00007589, www.germanctr.de), January 15, 2015.
The aim of the study was to develop and evaluate the reliability and agreement of new computer planimetric method for measurement and assessment of plaque on all types of removable dental prostheses RPDs. The instrument (new method) was tested by evaluating the efficacy of the rotating needles device in cleaning specific parts of RPD. From a database containing 780 images, which were taken in a standardized method for 65 RDPs for 49 participants, 55 images were selected randomly for image analysis. Adobe Photoshop software was used according to a standard operating procedure (SOP) by a main examiner two times in different sessions, and 1 time by 3 other examiners. In order to estimate the intra- and inter-examiner reliability, intraclass correlation coefficients ICC(2,1) was used. Three parameters were used to estimate agreement: standard error of measurement (SEM), smallest detectable change at 95% confidence level (SDC95%), and limits of agreement (LoA) according to Bland¨CAltman method. In the database, only 34 subjects were found with double crown retained removable denture and veneer over the secondary crown. 49x2 (before x after) images for 34 RDPs went under image analyses to calculate POP before and after cleaning the RDPs with the rotating needle device. Data were analysed using Wilcoxon signed-rank test. In all steps of image analysis, both intra-examiner and inter- examiner reliability were excellent with ICC(2,1) values > 0.85 at 95% confidence level. Intra- and inter-examiner values for both, SEM and SDC95% were ¡Ü 6% and ¡Ü17% respectively. The Bland¨CAltman analysis revealed a satisfactory level of agreement. POP is significantly more on the veneer than on the base(B-O), P <0.05. The rotating needles device is effective in cleaning the veneer and base(B-O), P <0.05 with absolute effect size 0.62. No statistical significance was detected in the effectiveness of the rotating needles device between base(B-O) and veneer. This study showed an excellent inter- and intra-examiner reproducibility, satisfactory level of examiners agreement, and acceptable measurement error of the new computer planimetric method . Furthermore, the method can be used with all types of RDPs. The rotating needles device can significantly reduce plaque on the double crown retained removable denture. The Computerized Planimetric Method (CPM) is more suitable for clinical researches because of its objectivity, reliability, high level of standardization, and the ability to detect and quantify small changes in plaque. Extra attention should be given to the veneer over the secondary crown as they are a potential part for RDP plaque accumulation.