Refine
Year of publication
Document Type
- Doctoral Thesis (121)
- Article (30)
Has Fulltext
- yes (151)
Is part of the Bibliography
- no (151)
Keywords
- - (24)
- Händedesinfektion (15)
- Hygiene (10)
- Polihexanid (10)
- Antiseptik (9)
- Chlorhexidin (7)
- Wundinfektion (7)
- MRSA (6)
- Plasma (6)
- Atmosphärendruckplasma (5)
- Bakterien (5)
- Biofilm (5)
- Octenidin (5)
- PHMB (5)
- plasma medicine (5)
- Antiseptikum (4)
- Desinfektion (4)
- Handschuh (4)
- Haut (4)
- Hautschutz (4)
- Infektion (4)
- Krankenhaushygiene (4)
- Resorption (4)
- Wunde (4)
- Zahnmedizin (4)
- hygiene (4)
- Aufbereitung (3)
- CAP (3)
- Cytotoxizität (3)
- Desinfektionsmittel (3)
- Iod (3)
- Povidon-Iod (3)
- Prüfkörpertest (3)
- SSI (3)
- Silber (3)
- antibiotics (3)
- antiseptics (3)
- chronic wounds (3)
- compliance (3)
- reactive oxygen and nitrogen species (3)
- surgical site infection (3)
- Antibiotika (2)
- Antibiotikum (2)
- Antisepsis (2)
- Antiseptic (2)
- Antiseptic efficacy (2)
- Antiseptics (2)
- Antiserum (2)
- Arzneimittel (2)
- Belastung (2)
- Bettenaufbereitung (2)
- Biatain Ag (2)
- Büro (2)
- Dentaleinheit (2)
- Ethanol (2)
- Hautantiseptik (2)
- Hautpflege (2)
- Hospitalismus <Hygiene> (2)
- Händehygiene (2)
- Kaltes Plasma (2)
- Krankenhaus (2)
- Latex (2)
- Multidrug-Resistenz (2)
- Neugeborene (2)
- Nitrile (2)
- Octenidine dihydrochloride (2)
- Phosphatidylcholin (2)
- Plasmamedizin (2)
- Polihexanide (2)
- Propan-1-ol (2)
- Propanol (2)
- Prävention (2)
- Pseudomonas aeruginosa (2)
- RNS (2)
- ROS (2)
- Raumluft (2)
- Rettungswesen (2)
- Skin barrier (2)
- Staphylococcus aureus (2)
- Staphylococcus epidermidis (2)
- Stratum corneum (2)
- Tissue Tolerable Plasma (2)
- Wound (2)
- Wundheilung (2)
- Wundverband (2)
- Zahnarztpraxis (2)
- Zahnpflege (2)
- antisepsis (2)
- antiseptic stewardship (2)
- biocide (2)
- biofilm (2)
- cancer (2)
- chirurgische Händedesinfektion (2)
- chlorhexidine (2)
- chronic wound (2)
- chronische Wunden (2)
- cold physical plasma (2)
- contamination (2)
- cross-resistance (2)
- cross-tolerance (2)
- nosocomial infections (2)
- training (2)
- 2-Phenoxyethanol (1)
- 5 moments (1)
- Absorption (1)
- Acanthamoeba (1)
- Acetaldehyd (1)
- Actin (1)
- Actisorb Silver 220 (1)
- Agardiffusion (1)
- Agardilution (1)
- Age- and Sex-distribution (1)
- Aktin (1)
- Aktivkohle (1)
- Akzeptanz (1)
- Albumin (1)
- Alkoholabstinenznachweis (1)
- Alkohole (1)
- Alkoholresorption (1)
- Allergie (1)
- Allergisches Asthma (1)
- Aminobuttersäure <gamma-> (1)
- Analyse (1)
- Angewandte Mikrobiologie (1)
- Anodische Oxidation <Oberflächenbehandlung> (1)
- Anti-Plaque-Wirksamkeit (1)
- Antibiose (1)
- Antibiotika-assoziierte Colitis (1)
- Antibiotikaresistenzen (1)
- Antiinfektiva (1)
- Antimicrobial (1)
- Antimicrobial efficacy (1)
- Antimikrobielle Eigenschaft (1)
- Antioxidants (1)
- Antioxidatives Potential (1)
- Antiphlogistikum (1)
- Antiseptic mouth rinse (1)
- Antiseptika (1)
- Antiseptische Spülung (1)
- Antiseptische Wirksamkeit (1)
- Anästhesie (1)
- Apoptosis (1)
- Aquacel (1)
- Argonplasma (1)
- Arzneimittelwechselwirkung (1)
- Arzneistoffe (1)
- Asepsis (1)
- Atmospheric pressure plasma (1)
- Atmosphärendruck (1)
- Aufbereitungsformen (1)
- Augenantiseptik (1)
- Ausbildung (1)
- Bacteria (1)
- Bacterial vaginosis (1)
- Bakterizid (1)
- Barriere (1)
- Bauchfellentzündung (1)
- Behaarung (1)
- Benetzung (1)
- Berlin / Robert-Koch-Institut (1)
- Beschichtung (1)
- Besiedlung (1)
- Betten (1)
- Bioassay (1)
- Biocidal product regulation (1)
- Biokompatibilität (1)
- Biosorb (1)
- Blood supply (1)
- CAP , Plasma , Melanom , Sphäroid , Krebs <Medizin> (1)
- CHX (1)
- COVID-19 (1)
- Candida albicans (1)
- CarboFlex (1)
- Carcinogen (1)
- Central Sterile Supply Departement (1)
- Check-In (1)
- Check-Out (1)
- Checkliste (1)
- Chemotherapie (1)
- Chloraniline (1)
- Chlorhexidine (1)
- Chlorhexidine digluconate (1)
- Chlornitrobenzen (1)
- Chorioallantoismembran (1)
- Chronic renal failure (1)
- Community Medicine (1)
- Compliance (1)
- Compliance <Patient> (1)
- Comunity Medicine (1)
- Connexin (1)
- Contreet-H (1)
- Cx43 (1)
- Cystein (1)
- Cytokine secretion (1)
- DIN 12791 (1)
- DIN 14729 (1)
- DIN EN 12791 (1)
- DIN EN ISO 14729 (1)
- Dauer (1)
- Dekontamination (1)
- Dekubitus (1)
- Demographic change (1)
- Dialyse (1)
- Dielectric barrier discharge (1)
- Drei-Kammer-Verfahren (1)
- Durchfall (1)
- EN 1500 (1)
- ERIS (1)
- Effektivität (1)
- Efficacy (1)
- Effizienz (1)
- Einreibedauer (1)
- Einwirkzeit (1)
- Elektrochemische Oxidation (1)
- Elektrostimulation (1)
- Empfindlichkeit (1)
- Encasing (1)
- Endotoxin (1)
- Energy supply (1)
- Entscheidungsbaum (1)
- Epidemiologie (1)
- Epidermis (1)
- Erkältungskrankheit (1)
- Erregerzahl (1)
- Escherichia coli (1)
- Estradiol (1)
- EtG (1)
- Ethanol based hand rub (1)
- Ethylglucuronid (1)
- Etiology (1)
- Explantationstest (1)
- Exposition (1)
- Expositionsmessung (1)
- Extended-Spectrum Beta-Lactamase (1)
- Extrakorporale Dialyse (1)
- Eye antisepsis of slaughtered pigs (1)
- Factors for exacerbation (1)
- Fahreignungsbegutachtung (1)
- Fehlzeit (1)
- Fibroblast (1)
- Filtration (1)
- Flow-Cell (1)
- Flüssigkeit (1)
- Fragebogenerhebung (1)
- Frageborgen (1)
- Frauenmilch (1)
- Frequency in childhood (1)
- Früherkennung (1)
- Frühgeborenes (1)
- Fungi (1)
- Funktionseinheit (1)
- GABAA-Rezeptor (1)
- GIS (1)
- Galenics (1)
- Galenik (1)
- Gemeinschaftspraxis (1)
- Genital tract infection (1)
- Geographical (1)
- Gesundheitsstörung (1)
- Gesundheitsökonomie (1)
- Ghana (1)
- Glomerulonephritis (1)
- Glove (1)
- Gram-negative Bakterien (1)
- Gram-positive Bakterien (1)
- Granudacyn® (1)
- Grauer Star (1)
- Greifswald / Universität (1)
- Guanidinthiocyanat (1)
- HDBD (1)
- HET- CAM (1)
- HET-CAM (1)
- HET-MN (1)
- Hair follicle (1)
- Hand antisepsis (1)
- Handschweiß (1)
- Hausstaub (1)
- Hautbarriere (1)
- Hautdesinfektion (1)
- Hautflora prEN12791 handrubs chirurgisch (1)
- Hautmodell (1)
- Heil- und Hilfsmittel (1)
- Hepatitis B (1)
- Hexachlorophene (1)
- Hippocampus (1)
- Honig (1)
- Hormesis (1)
- Hornschicht (1)
- Human papilloma virus (1)
- Hygiene <Motiv> (1)
- Hygiene costs (1)
- Hygieneausgaben (1)
- Hygienekosten (1)
- Hygienemaßnahme (1)
- Hygieneordnung (1)
- Hygienestandard (1)
- Hygienic safety reusable tap water filters Germlyser® (1)
- Hygienische Händedesinfektion (1)
- Hypochlorous acid (1)
- Hühnerei (1)
- ISAAC (1)
- Immunstimulation (1)
- Implant surface (1)
- In vitro (1)
- In vivo laser scanning microscopy (1)
- Inactivation (1)
- Inaktivator (1)
- Inaktivierung (1)
- Indikatorhandschuhe (1)
- Indikatorsystem (1)
- Infektionen (1)
- Infektionskontrolle (1)
- Infektionsrate (1)
- Inflammation (1)
- Infusionssystem (1)
- Inhibitor (1)
- Intensivstation (1)
- Interaktion (1)
- Iodausscheidung (1)
- Iodresorption (1)
- Irritationsdermatitis (1)
- Katarakt (1)
- Keap1 (1)
- Kinder (1)
- Kompatibilität (1)
- Kontaktekzem (1)
- Kontaktlinse (1)
- Kontaktlinsenpflegemittel (1)
- Kontaktlinsenpflegesysteme (1)
- Kontamination (1)
- Kosten (1)
- Kostenanalyse (1)
- Kostensenkung (1)
- Krankentransport (1)
- Kurzinfusionen (1)
- Kurzinfusionssystem (1)
- Kühlwasser (1)
- LAL-Test (1)
- LVPC (1)
- Labyrinthversuch (1)
- Laminar air flow (LAF) (1)
- Langzeitwirkung (1)
- Latexhandschuhe (1)
- Lavasept (1)
- Lecithine (1)
- Leginella pneumophila (1)
- Lipofundin (1)
- Liposomen (1)
- Liposoms (1)
- Lumbalpunktion (1)
- MSSA (1)
- Maisstärke (1)
- Maisstärkepuder (1)
- Mantelgas (1)
- Massagemittel (1)
- Material (1)
- Matratzenbezüge (1)
- Maus (1)
- Maximalversorgung (1)
- Mecklenburg Vorpommern (1)
- Mecklenburg-Strelitz (1)
- Mecklenburg-Vorpommern / Rettungsdienstgesetz (1)
- Medihoney (1)
- Medizin (1)
- Medizinprodukt (1)
- Meerschweinchen (1)
- Melanom (1)
- Membranfilter (1)
- Memorandum (1)
- Menschliches Serum (1)
- Mikrobielle Raumluftbelastung (1)
- Mikroperforationen (1)
- Mikrowellen (1)
- Milben (1)
- Mitochondrium (1)
- Modell (1)
- Molecular dynamics simulation (1)
- Mucin (1)
- Mucositis (1)
- Mucous Membrane (1)
- Mundhöhle (1)
- Mundspülung (1)
- Mutagenität (1)
- Muttermilch (1)
- Nanopartikel (1)
- Nase (1)
- Neugeborenes (1)
- Neurotoxicity (1)
- Neutralisator (1)
- Neutralisierung (1)
- Neutralization (1)
- Nitrilhandschuhe (1)
- Non-enveloped viruses (1)
- Nosokomiale Infektion (1)
- Nosokomiale Infektionen (1)
- Nrf2 (1)
- Nutztiere (1)
- OCT (1)
- OP-Dauer (1)
- ORP (1)
- Octenidindihydrochlorid (1)
- Octenidine (1)
- Octenidine dihydrochlorid (1)
- Octenidol® md (1)
- Octenisept (1)
- Operation (1)
- Operationen (1)
- Oralchirurgie (1)
- Oxidativer Stress (1)
- Oxygen supply (1)
- PEF (1)
- PHMB adsorption (1)
- PTS (1)
- PVP-Iod (1)
- PVP-iodine (1)
- Parenterales Arzneimittel (1)
- Partikelzahl (1)
- Pasteurisierung (1)
- Pathogener Mikroorganismus (1)
- Patient safety (1)
- Penetration (1)
- Perforation (1)
- Perforation <Medizin> (1)
- Perforationsrate (1)
- Peripheral venous catheters (1)
- Peritoneallavage (1)
- Personalschutz (1)
- Pharmazeutische Technologie (1)
- Phosphatidylcholine (1)
- Physiotherapie (1)
- Plasma treatment in vivo (1)
- Plasmaeffekt (1)
- Pneumatic Tube System (1)
- Pneumatisches Tube System (1)
- Poly (hexamethylene biguanide) hydrochloride (PHMB) (1)
- Poly(hexamethylene)biguanide (1)
- Polyhexamethylenbiguanid (1)
- Polyhexamethylene biguanide (1)
- Polyhexanide (1)
- Postoperative Wundinfektionen (1)
- Povidone-iodine (1)
- Prion (1)
- Produktivitätsverlust (1)
- Prognose (1)
- Prognosis (1)
- Prontosan (1)
- Propan-2-ol (1)
- Propanole (1)
- Prophylaxe (1)
- Propionibakterien (1)
- Prüfanschmutzung (1)
- Puder (1)
- Qualitätsmanagement (1)
- RKI-Richtlinie (1)
- RNA (1)
- Ratten (1)
- Raumklima (1)
- Reconstructed human epidermis (1)
- Red blood cell concentrates (1)
- Redox signaling (1)
- Redoxpotential (1)
- Reizwirkung (1)
- Residual antimicrobial effect (1)
- Resistenz (1)
- Rettungsdienst (1)
- Ringer-Wundspüllösung (1)
- Ringer’s solution (1)
- Risikoanalyse (1)
- Risk–benefit-assessment (1)
- Rose Bengal staining (1)
- S. sanguinis Biofilm (1)
- SARS-CoV-2 (1)
- SKH1 mouse model (1)
- SR101 (1)
- SaOs‐2 cell differentiation (1)
- Schadstoffbelastung (1)
- Schilddrüse (1)
- Schimmelpilze (1)
- Schimmelpilzschaden (1)
- Schlachtschwein (1)
- Schleimhaut (1)
- Schule (1)
- Schulung (1)
- Screening (1)
- Sedimentation (1)
- Seife (1)
- Sekundärleistung (1)
- Sepsis (1)
- Sieben <Verfahrenstechnik> (1)
- Silver wound dressing (1)
- Sodium hypochlorite (1)
- Sporozide Händedesinfektion (1)
- Spülen (1)
- Sterilität <Hygiene> (1)
- Streptococcus mutans (1)
- Streptococcus sanguinis (1)
- Streptococcus sanguis (1)
- Suction blister (1)
- Suction blister technique (1)
- Surface barrier discharge plasma source (1)
- TEER (1)
- THP-1 macrophages (1)
- Tempus 600 (1)
- Therapy (1)
- Thiolgruppe (1)
- Ti6Al4V (1)
- Ti6Al4V alloy (1)
- TiO2 (1)
- Tissue tolerable plasma (1)
- Tissue-tolerable plasma (1)
- Training (1)
- Transepidermal water loss (1)
- Trinkwasser (1)
- Trinkwasserverordnung (1)
- UVA-LED (1)
- UVA-responsive (1)
- Ultraschall (1)
- Ultraschallkopf (1)
- Ultraschallsonde (1)
- Umweltanalyse (1)
- Umweltbericht (1)
- Umwelterklärung (1)
- Unterschenkelgeschwür (1)
- Untersuchungshandschuhe (1)
- Unterziehhandschuhe (1)
- VUV radiation (1)
- Validierung (1)
- Verwaltung (1)
- Virusinfektion (1)
- Vorpommern (1)
- WHO (1)
- WSP (1)
- Waschung (1)
- Wasseraufbereitung (1)
- Wasserdesinfektion (1)
- Wassergüte (1)
- Wasserhygiene (1)
- Wasserleitung (1)
- Wasserlinse (1)
- Wassersicherheitsplan (1)
- Wasserstoffionenkonzentration (1)
- Wasserstoffperoxid (1)
- Water Safety Plan (1)
- Water-filtered infrared-A radiation (1)
- Wirksamkeit (1)
- Wirksamkeitstestung (1)
- Wirtschaftlichkeit (1)
- Wirtschaftlichkeitsprinzip (1)
- Wirtschaftlichkeitsprüfung (1)
- Worker safety (1)
- Wound antiseptics, HET-CAM, irritation score, octenidine, chlorhexidine, polihexanide, hypochlorite, hydrogen peroxide, hemoglobin spray, allantoin, dexpanthenol, thiocyanate. (1)
- Wound at risk of infection (1)
- Wound at risk score (W.A.R. score) (1)
- Wound colonization (1)
- Wound healing (1)
- Wound management (1)
- Wound secretion (1)
- Wundantiseptik (1)
- Wundauflage (1)
- Wunde <Motiv> (1)
- Wundmodelle (1)
- Wundreinigung (1)
- Wundspülung (1)
- Wundversorgung (1)
- Wurzelkanalinstrument (1)
- ZSVA (1)
- Zahnbelag (1)
- Zahnklinik (1)
- Zellkommunikation (1)
- Zellmigration (1)
- Zellskelett (1)
- Zentrale Venenkatheter (1)
- Zinkoxid (1)
- Zoonose (1)
- Zwischenspülungen (1)
- absorption (1)
- activated carbon (1)
- alkoholische Händedesinfektionsmittel (1)
- allergic (1)
- ambulance car/rescue service (1)
- ambulance service (1)
- ambulanter Sektor (1)
- amino fluoride (1)
- anaesthesia (1)
- antimicrobial (1)
- antimicrobial activity (1)
- antimicrobial coating (1)
- antimicrobial efficacy (1)
- antimikrobiell (1)
- antimikrobielle Substanzen (1)
- application time (1)
- aseptisch (1)
- asthma (1)
- atmospheric pressure (1)
- bacteria (1)
- bakterielle Translokation (1)
- bed processing (1)
- carbon contamination (1)
- carcinogenic (1)
- cataract (1)
- cfu (1)
- checklist (1)
- chlorine (1)
- chloroaniline (1)
- chronische Krankheit (1)
- chronische Wunde (1)
- cold atmospheric plasma (1)
- cold atmospheric pressure plasma (1)
- cold atmospheric pressure plasma (CAP) (1)
- comparison (1)
- confocal laser scanning microscopy (1)
- contact killing surface (1)
- cooling water (1)
- cost analysis (1)
- cytotoxicity (1)
- decontamination (1)
- dental clinic (1)
- dermal (1)
- dermal exposition (1)
- dermal full-thickness wounds (1)
- dermatologic effect (1)
- dermatologischer Nutzen (1)
- desinfections and antiseptics (1)
- dezentrale Aufbereitung (1)
- diabetic foot (1)
- dialysis (1)
- disc carrier test (1)
- double gloving (1)
- dressing; silver; antibacterial activity (1)
- drinking-water (1)
- duwl (1)
- dynamic light scattering (1)
- education (1)
- effectiness (1)
- endotoxin binding (1)
- ethanol resorption (1)
- examination gloves (1)
- exposure (1)
- exposure time (1)
- filtration (1)
- fluoride gels (1)
- gefässkatheterassozzierte Infektionen (1)
- gewebeverträgliches Plasma (1)
- hair follicles (1)
- hairiness (1)
- hand desinfection (1)
- hand disinfection (1)
- hand hygiene (1)
- hand hygiene; hand rub; hand disinfection; skin care; interaction; EN 1500 (1)
- hand-hygiene (1)
- health and safety protection at the workplace (1)
- health economics (1)
- hepatitis b (1)
- hospital of maximum care (1)
- house dust (1)
- hydrogen peroxide (1)
- hydroxyethyl starch (1)
- hygiene reglement (1)
- hygienic hand desinfecrion (1)
- hygienic hand rub (1)
- hygienische Händedesinfektion (1)
- hypochlorous acid (1)
- immune response stimulation (1)
- implant coating (1)
- indoor air (1)
- inductively-limited discharge (1)
- infected wounds (1)
- infection control (1)
- infection prophylaxis (1)
- infection rate (1)
- infectious virus (1)
- inflammation (1)
- interaction (1)
- iodine (1)
- ion chromatography (1)
- irritation potential (1)
- isopropyl alcoholic absorption (1)
- isotonische Kochsalzlösung (1)
- kINPen (1)
- kINPen 09 (1)
- kINPen MED (1)
- kINPen plasma jet (1)
- kINPen09 (1)
- kINPenMed (1)
- kINpen (1)
- kaltes Atmosphärendruck-Argon-Plasma (1)
- kaltes Atmosphärendruckplasma (1)
- kaltes nicht thermisches Plasma (1)
- keine Angaben (1)
- kinpen09 (1)
- kontaminiertes Wasserreservoir (1)
- latex gloves (1)
- lenscare (1)
- liquids (1)
- low temperature plasma (1)
- macaques (1)
- medical devices (1)
- micelle (1)
- microbiology (1)
- microperforations (1)
- microwave (1)
- mikrobiologische Wasseranalyse (1)
- moDCs (1)
- mould damage (1)
- moulds (1)
- mouth rinse (1)
- mouthwash (1)
- mucosa model (1)
- mucositis (1)
- multi-resistant pathogens (1)
- multidrug-resistant microorganisms (1)
- nanocapsules (1)
- nitrate (1)
- nitrile gloves (1)
- nitrite (1)
- non-thermal plasma (1)
- nosokomial (1)
- nosokomiale Infektion (1)
- nosokomiale Infektionen (1)
- o/w-Emulsion (1)
- o/w-Emulsions (1)
- observance of hygiene (1)
- octenidindihydrochloride (1)
- octenidine dihydrochloride (1)
- osseointegration (1)
- outpatient setting (1)
- particle number (1)
- patiententransport (1)
- perforation rate (1)
- peripherer venöser Gefäßkatheter (1)
- peroxynitrite (1)
- physikalische Therapie (1)
- physiological saline solution (1)
- plaque (1)
- plasma discharge (1)
- plasma-treated water (1)
- polihexanide (1)
- polyhexamethylene biguanide (1)
- porcine skin model (1)
- postoperative Infektion (1)
- postoperative Wundinfektionen (1)
- postoperative wound infections (1)
- prevention (1)
- pulmonal (1)
- pulsed electric current (1)
- quantitative suspensiontest (1)
- quantitativer Suspensionstest (1)
- questionary survey (1)
- questionnaire (1)
- reactive oxygen species (1)
- reactive species (1)
- redox biology (1)
- redox signaling (1)
- reprocessing (1)
- rescue service (1)
- responsibility (1)
- rettungsdienst (1)
- rhino virus (1)
- rhinoconjunctivitis (1)
- risk assessment (1)
- risk evaluation (1)
- routine floor disinfection (1)
- routinemäßige Fussbodendesinfektion (1)
- sealant (1)
- secondary achievements (1)
- septisch (1)
- settled dust (1)
- sieving (1)
- silver wound dressing (1)
- skin (1)
- skin antisepsis (1)
- skin-compatibility (1)
- skincare (1)
- skinprotection (1)
- soap (1)
- sodium monofluorophosphate (1)
- soft lenses (1)
- source of transmission (1)
- surface (1)
- surface modification (1)
- surgical hand preparation (1)
- synaptic spines (1)
- synaptische Dornen (1)
- tap water (1)
- tape stripping model (1)
- three-chamber model (1)
- thyroid (1)
- titanium alloys (1)
- toothpaste (1)
- total bacterial count (1)
- transdermaler Ultraschall (1)
- treatment control (1)
- turbulente Verdünnungsströmung (1)
- turbulenzarme Verdrängungsströmung (1)
- ultrasonic probe (1)
- undergloves (1)
- vaccine (1)
- viral load (1)
- water contact angle (1)
- water safety plan (1)
- waterborne infections (1)
- wettability (1)
- wetting (1)
- wiederaufbereitbare Wasserfilter steril Trinkwasser Trinkwasserpathogenen (1)
- wound antisepsis (1)
- wound healing (1)
- wound irrigation (1)
- wound rinsing (1)
- wound test-model (1)
- Übertragungswahrscheinlichkeit MRSA (1)
- Übung (1)
Institute
- Institut für Hygiene und Umweltmedizin (151) (remove)
Publisher
- MDPI (14)
- S. Karger AG (10)
- BioMed Central (BMC) (3)
- Frontiers Media S.A. (1)
- IOP Publishing (1)
- Wiley (1)
Die Händedesinfektion ist essentiell zur Verhinderung nosokomialer Infektionen. Hierbei zeigen sich alkoholische Desinfektionsmittel auf Basis von Ethanol und Propanolen als besonders effektiv. Bei ethanolhaltigen Desinfektionsmitteln konnte eine Resorption im toxisch relevanten Ausmaß ausgeschlossen werden. Bei der Anwendung von Propanolen fanden sich nach exzessiver Händedesinfektion erhöhte Serumspiegel, die eine Bewertung unter Praxisbedingungen notwendig machten, um eine gesundheitliche Gefährdung durch Anwendung im täglichen Gebrauch auszuschließen. In diesem Zusammenhang stellte sich die Frage, ob es bei praxisnaher chirurgischer Händedesinfektion mit okkludierter Haut eine relevante dermale Resorption der Propanole gibt und ob diese als gesundheitsgefährdend anzusehen ist. Auf Grund der Literaturrecherche zu Resorptionsvorgängen an der Haut war eine dermale Resorption wahrscheinlich. Die Anzahl von in-vitro Untersuchungen überwiegt jedoch. Nur wenige in-vivo Studien beschäftigen sich mit der Frage, ob und in welchem Ausmaß Propan-1-ol und Propan-2-ol im Rahmen der alkoholischen Händedesinfektion resorbiert werden. Mit Hilfe von 10 operativ tätigen Probanden wurden bei 3 verschiedenen propanolhaltigen Desinfektionsmitteln (Gehalt von 70 % [w/w] Propan1-ol, 63,14 % [w/w] Propan-2-ol, 30 % [w/w] Propan-1-ol und 45 % [w/w] Propan-2-ol) die dermale Resorption nach Applikation untersucht. Je Proband kam an drei verschiedenen Tagen jeweils eines der Desinfektionsmittel zum Einsatz. An jedem Versuchstag erfolgten eine hygienische und drei chirurgische Händedesinfektion mit dem jeweils zu testenden Präparat in vorgegebenen Zeiträumen. Zu verschiedenen Zeitpunkten wurden Blutproben genommen, um die Resorption und die Metabolisierung in Ausmaß und zeitlichem Verlauf darstellen zu können. Durch die Untersuchung der Blutproben fanden wir signifikante Erhöhungen der Propanol-Serumspiegel unabhängig vom verwendeten Präparat. Die maximale mediane Blutkonzentration wurde für Propan-1-ol bei 4,09 mg/l und für Propan-2-ol mit 2,56 mg/l bestimmt. Der maximale Serumspiegel von Propan-1-ol wurde mit 25,8 mg/l und bei Propan-2-ol unter der Verwendung des Propan-1-ol Monopräparats mit 5,4 mg/l ermittelt. Bei der Verwendung der Wirkstoffkombination traten maximale Serumspiegel von 9,7 mg/l für Propan-1-ol und 5,3 mg/l für Propan-2-ol auf. Für den 44 Metaboliten von Propan-1-ol, Aceton, fanden wir in allen Versuchen einen signifikanten Anstieg. Für Propionaldehyd, der Hauptmetabolit von Propan-2-ol, waren keine Erhöhungen messbar. Die gemessenen Werte zeigen eine Beziehung zwischen Applikation und Resorption der Propanole auf, die signifikant ist, aber im Vergleich zu toxikologisch relevanten Mengen gering erscheint. Unklar ist der Einfluss einer pulmonalen Resorption. Eine akute gesundheitliche Gefährdung durch eine Propanolresorption im Zusammenhang mit der chirurgischen Händedesinfektion ist bei gesundem Anwender und vorschriftsmäßiger Applikation unwahrscheinlich. Die langfristigen Auswirkungen sind durch die vorliegenden Daten nicht sicher abschätzbar. Bei weiteren Studien sollte die pulmonale Resorption berücksichtigt werden.
Gegenstand der hier vorgestellten Arbeit ist die Beschichtung von Wundauflagen mit Zinkoxid- und Silberhaltigen antibakteriellen Schichten. Die Aufbringung der Schichten erfolgt dabei auf den Wundauflagen mittels Atmosphärendruckplasma. Die Matrix der Schichten besteht aus Siliziumdioxid, in welcher die Wirkstoffe eingelagert sind. Auf diesem Weg hergestellten Wundauflagen wurden hinsichtlich ihrer antibakteriellen Wirkung und zytotoxischen Eigenschaften charakterisiert. Ziele waren ein minimaler Einsatz an Wirkstoffen und die Nutzung eines modernen Beschichtungsverfahrens. Der zytotoxische Einfluss der Wundauflagen wurde an 3D-Hautmodellen im Vergleich zu den am Markt befindlichen Produkten validiert.
Der Gesetzgeber verlangt aus Gründen der Arzneimittelsicherheit für nasal anwendbare Arzneimittel und Medizinprodukte (Nasalia) in Mehrdosisbehältnissen den Zusatz von geeigneten Konservierungsmitteln in angemessener Konzentration (Eu. Pharm. 2001). Diese dienen dem Schutz des Inhalts vor Keimen aus der Umgebung nach Anbruch (mikrobiologische Anbruchstabilität). Es gibt kein Konservierungsmittel, das alle Anforderungen erfüllt und universell für alle Formulierungen einsetzbar ist. Da Konservierungsmittel per Definition Keime abtöten bzw. ihre Vermehrung verhindern muss, ist zwangsläufig eine gewisse Zytotoxizität gegeben. Da die meisten Nasalia immer noch konserviert sind, lässt sich die Forderung des Arzneibuchs nach Zubereitungen zur nasalen Applikation, die nicht reizend sind und keine unerwünschten Wirkungen auf die Funktion der mukoziliaren Clearance ausüben, in diesem Fall nur bedingt erfüllen. Der Kompromiss zwischen Verträglichkeit und mikrobiologischer Sicherheit geht bei den konservierten Präparaten auf Kosten der Verträglichkeit. Dabei addieren sich die zytotoxischen Eigenschaften der arzneilich wirksamen Substanz mit der Zytotoxizität des Konservierungsmittels. Grundsätzlich ist daher der Einsatz von Konservierungsmitteln in der heutigen Zeit zu hinterfragen. Mit Hilfe dieser Substanzen werden nur die Folgen einer mikrobiologischen Kontamination bekämpft, anstatt die Ursachen auszuschließen. Moderne Pumpsysteme machen es möglich, konservierungsmittelfreie Nasensprays herzustellen und so den umstrittenen Zusatz des am häufigsten eingesetzten Konservierungsmittels Benzalkoniumchlorid zu vermeiden. Im Rahmen dieser Arbeit wurden folgende Ergebnisse erzielt: - In der größten und am häufigsten eingesetzten Gruppe der Vasokonstriktiva (Xylometazolin, Oxymetazolin, Tetryzolin, Tramazolin) wurde durch den Verzicht auf Benzalkoniumchlorid ein signifikanter Anstieg der Verträglichkeit registriert. Da diese Kombination von Wirkstoff und Konservierungsmittel besonders zellschädigend ist, ist es empfehlenswert auf konservierte Formulierungen zu verzichten. In der Gruppe der Antiallergika wurden mit Ausnahme von Cromo-ratiopharm analoge Ergebnisse erzielt. Die schlechte Verträglichkeit (Zellwachstum nur 1,1%) der unkonservierten Formulierung ist auf die Matrix (hypoton) zurückzuführen. In der Gruppe der Kortikosteroide sind alle Formulierungen konserviert und schlecht verträglich. Neue Entwicklungspräparate (ölige Matrix, unkonserviert, ohne Hilfsstoffe) sind dagegen gut verträglich. Hier bietet sich eine Möglichkeit, preiswerte und gut verträgliche Präparate herzustellen, vor allem für die Patientengruppen, die über Brennen, Trockenheit oder Irritationen nach Benutzung der herkömmlichen Nasalia klagen. In der Gruppe der Heil- und Pflegemittel mit arzneilichen Zusätzen sind alle un-konservierte Präparate gut verträglich. Der Verzicht auf Benzalkoniumchlorid erhöht die Verträglichkeit. Die getesteten Öle sind ebenfalls gut verträglich. In Bereich der Hormone scheint die Faustregel der besseren Verträglichkeit nach Verzicht auf Benzalkoniumchlorid nicht immer zu gelten. Die wachstumsfördernde Wirkung des Hormons Calcitonin scheint einen Einfluss auf die Ergebnisse der Zytotoxizitätstest zu haben. In der Gruppe saliner Lösungen sind alle Nasensprays konservierungsmittelfrei und gut verträglich. Der Zusatz von Dexpanthenol hat einen positiven Einfluss auf die Verträglichkeit. Der Zusatz von Aloe vera hat keinen keinen Einfluss auf die Verträglichkeit. Die Gruppe der Analgetika besteht vorwiegend aus Entwicklungspräparaten. Der Zusatz von Hyaluronsäure hat einen positiven Einfluss auf die Verträglichkeit, die bis auf Werte im Bereich saliner Lösungen liegen. Hier eröffnet sich eine zukünftige Möglichkeit, gut verträgliche Analgetika herzustellen. Die Reaktion des Gesetzgebers auf die in der Literatur reichlich beschriebenen Nebenwirkungen von Benzalkoniumchlorid lässt hoffen, dass vor allem die neu zugelassenen Nasensprays konservierungsmittelfrei und somit besser verträglich werden.
Background: Annual transfusion rates in many European countries range between 25 and 35 red blood cell concentrates (RBCs)/1,000 population.It is unclear why transfusion rates in Germany are considerably higher (approx. 50–55 RBCs/1,000 population). Methods: We assessed the characteristics of transfusion recipients at all hospitals of the German federal state Mecklenburg-Western Pomerania during a 10-year longitudinal study. Results: Although 75% of patients received ≤4 RBCs/patient in 2015 (1 RBC: 11.3%; 2 RBCs: 42.6%; 3 RBCs: 6.3%; 4 RBCs: 15.0%), the mean transfusion index was 4.6 RBCs due to a minority of patients with a high transfusion demand. Two thirds of all RBCs were transfused to only 25% of RBC recipients. Consistently, male patients received a higher number of RBCs (2005: 54.2%; 2015: 56.8%) and had a higher mean transfusion index than female patients (mean 5.1 ± 7.2; median 2; inter-quartile range [IQR] 2–4 vs. mean 4.0 ± 5.8; median 2; IQR 2–4). The absolute transfusion demand decreased between 2005 and 2015 by 13.5% due to a composite of active reduction (clinical practice change) and population decline in the 65- to 75-year age group (lower birth rate cohort 1940–1950); however, with major differences between hospitals (range from –61.0 to +41.4%). Conclusion: Transfusion demand in a population could largely be driven by patients with high transfusion demand. Different treatment practices in this group of patients probably add to the major differences in transfusion demand per 1,000 individuals between countries. The available data cannot prove this hypothesis. Implementation of a diagnosis-related group-based monitoring system is urgently needed to allow informative monitoring on the population level and meaningful comparisons between transfusion practices.
Im deutschen Gesundheitswesen stellt MRSA nicht nur im stationären, sondern auch im ambulanten Bereich eine Behandlungserschwernis dar. Patienten mit chronischen Wunden sind bei MRSA-Infektionen besonders gefährdet. Deshalb wurden als Ausgangslage für die vorliegende Arbeit die Forschungsfragen formuliert, ob a) eine ambulante MRSA-Sanierung bei Patienten mit chronischen Wunden durchführbar ist und b) die damit erzielbaren Fallerlöse die Praxiskosten decken. Zur Beantwortung der Frage wurden a) Berichtsdaten der Kassenärztlichen Bundesvereinigung an das Bundesministerium für Gesundheit b) Abrechnungsdaten der Kassenärztlichen Vereinigung Mecklenburg-Vorpommern und c) die Daten der MRSA-fokussierten MEracL-Studie (MRSA eradication for chronic lesions) analysiert. Auf Grund der Ergebnisse konnten fünf Kernaussagen formuliert werden: 1) Die Durchführung einer ambulanten Sanierungsbehandlung ist möglich. 2) Das Vorhandensein einer chronischen Wunde ist ein MRSA-Risikofaktor, aber kein Hemmnis für die Durchführung einer ambulanten Sanierungsbehandlung. 3) Die Akzeptanz der Ärzte hinsichtlich der Durchführung einer ambulanten Sanierungsbehandlung ist regional unterschiedlich. 4) Die errechneten Fallerlöse decken nicht die realen Praxiskosten. 5) Das Budget für Leistungen im Zusammenhang mit MRSA sollte sektorenübergreifend geplant und eingesetzt werden. Die vorliegende Arbeit unterstreicht die Wichtigkeit einer gesundheitsökonomischen Analyse bei der Einführung neuer Behandlungsmethoden.
Ziel der Studie war die Beantwortung der Fragestellung, ob es im Klinikum Pasewalk aus krankenhaushygienischer Sicht Einwände gegen einen Wechsel der orthopädischen Operationen von einer mit TAV ausgestatteten OP-Einheit in eine mit TVS belüftete OP-Einheit gibt. Zusätzlich sollten Einflussfaktoren auf die partikuläre und mikrobielle Belastung der Raumluft einschließlich der Rolle der RLT-A analysiert werden. Besonderes Interesse galt hierbei dem Messpunkt direkt am OP-Gebiet.
Als Qualitätsparameter der Raumluft wurden bei insgesamt 48 Operationen die Partikelkonzentration an drei Messpunkten und die mikrobielle Belastung der Raumluft an vier Messpunkten während des regulären OP-Betriebs in zwei OP-Einheiten gemessen. Zur Beurteilung der Partikelkonzentration der Raumluft an den 3 Messpunkten wurden Partikel der Größen 0,5 – 4,9µm und >5 µm kumulativ gemessen. Für die Erfassung der mikrobiellen Belastung der Raumluft wurden Sedimentationsplatten an 4 Messpunkten eingesetzt.
Die mikrobielle Belastung war an den Messpunkten am OP-Gebiet, am Instrumententisch und in der Nähe der aseptischen Arbeitsflächen im OP 1 mit TAV signifikant geringer als im OP 2 mit TVS. Zusätzlich wiesen alle Messpunkte eine signifikant geringere partikuläre Belastung (sowohl unterhalb als auch außerhalb der TAV) im OP 1 mit TAV auf.
Es konnte gezeigt werden, dass die Anzahl der im Hintergrund tätigen Personen die Partikelkonzentration (>5,0 µm) und die mikrobielle Belastung am OP-Gebiet erhöht. Diese Effekte sind nur in OP 2 mit TVS nachweisbar. Zudem konnte ein positiver Zusammenhang zwischen Partikelkonzentration (>5,0 µm) und mikrobieller Belastung festgestellt werden.
Als Fazit kann eine Empfehlung zum Wechsel der OP-Einheiten nicht ausgesprochen werden. Zudem konnte gezeigt werden, dass eine RLT-A mit TAV einen verringernden Einfluss auf die Erregerbelastung und Partikelbelastung am OP-Gebiet haben kann. Sie ist zudem über ihren Schutzbereich in der Lage Auswirkungen von Umgebungseinflüssen auf mikrobielle und partikuläre Belastung am OP-Gebiet signifikant zu verringern.
Durch die chirurgische Händedesinfektion soll eine möglichst effektive Verminderung der Koloniezahlen der Hände des chirurgischen Personals vor Durchführung eines operativen Eingriffs erreicht werden. Alle zusätzlich verwendeten Produkte sollten auf einen Einfluss auf die Händedesinfektion untersucht werden, um eine abschwächende Wirkung auszuschließen. Biosorb ist eine Handcreme, die von chirurgischem Personal nach dem Desinfizieren der Hände verwendet wird, um Flüssigkeitsreste aufzunehmen und so das Anlegen der OP-Handschuhe zu erleichtern. Hauptbestandteile des Produktes sind Ethanol und Maisstärke. In der vorliegenden Studie wurde Biosorb auf einen Einfluss auf die Langzeitwirkung der chirurgischen Händedesinfektion untersucht. Ebenfalls untersucht wurde, ob ein Einfluss auf die Handschweißproduktion im Handschuh durch die Anwendung von Biosorb nachweisbar ist. Dieses könnte die Gefahr von Hautschäden durch das im Handschuh herrschende feuchte Milieu vermindern. Es konnte in der vorliegenden mit 26 Probanden durchgeführten Studie nach 90 minütigem Handschuhtragen kein Effekt auf die Bakterienzahlen der Hände durch die Verwendung von Biosorb nachgewiesen werden. Auch die Menge des im Handschuh gebildeten Handschweißes wurde durch Bio-sorb nicht beeinflusst. Da eine Kontamination des OP-Gebiets mit der im Biosorb enthaltenen Maisstärke u.a. zu stärkeinduzierter Peritonitis, Adhäsionen, Wundheilungs-störungen und Tumorzellwachstum führen kann, sollte die Handcreme auf Grund des nicht nachweisbaren Einflusses auf die Schweißproduktion der Hände nicht mehr verwendet werden.
Es handelt sich um eine Anwendungsbeobachtung zur Ermittlung der Anzahl erforderlicher Händedesinfektionen im Stationsalltag anhand der von der WHO definierten Indikationen für die Händedesinfektion.
Bisher liegen Werte zur Häufigkeit der HD nur in der Intensivpflege vor, nicht
aber in sogenannten „Nichtrisikobereichen“, sodass die Bewertung von
Verbrauchsdaten nicht möglich ist.
Erstmalig wurden mit einer Beobachtungsstudie für zwei stationäre
Nichtrisikobereiche Richtwerte zur Anzahl erforderlicher HD und zusätzlich die
Compliance ermittelt.
Es wurden 2424 Indikationen zur HD dokumentiert. Eine Pflegekraft kommt im
Durchschnitt auf 70 (MKG) bzw. 161 (Nephrologie) Indikationen zur HD pro
Arbeitsschicht.
Beim ärztlichen Personal wurden durchschnittlich 16 (Nephrologie) bzw. 17
(MKG) Indikationen pro Arbeitsschicht beobachtet.
Im Mittel ist die Compliance der HD mit 61% auf der MKG-chirurgischen Station
und mit 65% auf der nephrologischen Station > 60%. Mit einem Wert von 66,7%
weist das ärztliche Personal der Nephrologie die höchste Compliance auf,
gefolgt vom ärztlichen Personal der MKG-Chirurgie mit einer Compliance von
66,1%, dem Pflegepersonal der Nephrologie mit 64,7% und der MKG-chirurgischen
Station mit 59,9%.
Nach Auswertung der Apothekenverbrauchswerte konnte gezeigt werden, dass die Compliance durch den Hawthorne-Effekt beeinflusst wurde.
Trotz im Klinikum ausreichend vorhandener Anzahl von Desinfektionsspendern
und Piktogrammen zur richtigen Durchführung der HD sowie geschultem
Personal ist die Compliance mit durchschnittlich 60% auf beiden Stationen
ähnlich hoch wie die Compliance auf Intensivstationen mit durchschnittlich 59%
(Scheithauer et al. 2009). Es wird offensichtlich, dass die Compliance auch in
Nichtrisikobereichen weiter verbessert werden muss.
Gegenstand der Arbeit ist die Kontamination von transdermalen Ultraschallsonden und deren klinische Relevanz. Dabei ist die Arbeit in zwei Teile unterteilt. Im ersten Teil wird ein ausführliches Review zu den relevanten Studien durchgeführt und die Ergebnisse der jeweiligen Studien analysiert und tabellarisch zusammengefasst. Im zweiten Teil werden durch eigenständig durchgeführte Versuche einerseits die Kontamination von transdermalen Sonden an einem Klinikum in einer Stichprobe und im Krankenhausroutinebetrieb untersucht, anderseits die Effektivität eines in Desinfektionsmittel getauchten, für Ultraschallsonden verträglichen Fertigwischtuchs getestet. Im Anschluss erfolgte die Evaluation der Praktikabilität der Wischtücher und der Änderung des Desinfektionsverhaltens des Personals nach Einführung der Wischtücher. Durch die vorliegende Arbeit konnte die klinische Relevanz der Kontamination von Ultraschallsonden und deren Rolle als Vektor bei der Übertragung von Infektionen aufgezeigt werden. Erstmalig liegt mit dieser Arbeit ein ausführliches Review über die bisherige Studienlage vor. Durch die eigenen Untersuchungen konnte die Effektivität der Fertigwischtücher im klinischen Alltag unter Praxisbedingungen getestet werden und unter bestimmten Voraussetzungen als ausreichend befunden werden. Aufgrund der Ergebnisse dieser Untersuchung wurden in der Zwischenzeit Fertigdesinfektionswischtücher für die gesamte Universitätsmedizin zur Desinfektion von Ultraschallsonden eingeführt.
Kontaktlinsenträger haben ein erhöhtes Risiko für Keratitiden. Die Ursache liegt u.a. in unzureichend wirksamen Kontaktlinsenpflegesystemen, insbesondere All-in-One Lösungen. Die vorliegende Studie liefert einen aktuellen Überblick über die meistverwendeten Kontaktlinsenpflegesysteme in Deutschland. Hauptaugenmerk war die Untersuchung unter Belastung mit 1% Albumin, 0,1% Mucin. All-in-One Lösungen wirken weiterhin insbesondere unter Belastung nur unzureichend. Mikrobiologisch sind daher z.Z. nur Wasserstoffperoxidlösung zu empfehlen.
Multiple evidence in animal models and in humans suggest a beneficial role of cold physical
plasma in wound treatment. Yet, risk assessment studies are important to further foster therapeutic
advancement and acceptance of cold plasma in clinics. Accordingly, we investigated the long-term
side effects of repetitive plasma treatment over 14 consecutive days in a rodent full-thickness ear
wound model. Subsequently, animals were housed for 350 days and sacrificed thereafter. In blood,
systemic changes of the pro-inflammatory cytokines interleukin 1β and tumor necrosis factor α
were absent. Similarly, tumor marker levels of α-fetoprotein and calcitonin remained unchanged.
Using quantitative PCR, the expression levels of several cytokines and tumor markers in liver,
lung, and skin were found to be similar in the control and treatment group as well. Likewise,
histological and immunohistochemical analysis failed to detect abnormal morphological changes
and the presence of tumor markers such as carcinoembryonic antigen, α-fetoprotein, or the neighbor
of Punc 11. Absence of neoplastic lesions was confirmed by non-invasive imaging methods such as
anatomical magnetic resonance imaging and positron emission tomography-computed tomography.
Our results suggest that the beneficial effects of cold plasma in wound healing come without apparent
side effects including tumor formation or chronic inflammation.
Vergleich der mikrobioziden Wirksamkeit verschiedener Zahngele in Relation zu einer Zahnpasta
(2012)
Die Mundhöhle stellt ein vielschichtiges Ökosystems für oralpathogene Mikroorganismen dar. Um den negativen Effekten wie Gingivitis, Parodontitis sowie Karies entgegenzuwirken, nehmen die regelmäßige Mundhygiene sowie spezielle Maßnahmen zur Reduktion unerwünschter mikrobieller Spezies einen wichtigen Platz im täglichen Leben ein. Auch auf Grund der zunehmenden Antibiotika-Resistenzentwicklung von Bakterien ist die positive Wirkung von mikrobiozid aktiven Dentalprodukten gegenüber oralpathogenen Mikroorganismen ein bedeutsames Forschungsthema. Die antibakterielle Aktivität verschiedenster Bestandteile in Dentalprodukten sowie der Dentalprodukte als Ganzes wurden in zahlreichen in-vitro und in-vivo Studien untersucht, nachgewiesen und basiert auf verschiedensten Mechanismen. Mit Hilfe eines modifizierten Keimträgertests wurde die mikrobiozide Wirkung von drei unterschiedlichen Chargen des Produkts Ledermix® Fluorid Gel im Vergleich zu Elmex®gelée und Meridol® Zahnpasta untersucht. Die Testung wurde gegenüber einer Hefespezies (C. albicans), einer grampositiven (S. aureus), drei kariogenen grampositiven (S. mutans, S. sanguis, S. pyogenes) und einer pathogenen gramnegativen (P. aeruginosa) Bakterienspezies vorgenommen. Als Ergebnis konnte festgestellt werden, das alle drei Ledermixprodukte bei allen Streptokokkenarten sowie C. albicans eine Reduktion ≥3,5 lg Stufen nach einer Einwirkzeit von 5 min erreichten. Elmex®gelée war gegenüber P. aeruginosa mit einem RF ≥5 lg- Stufen bereits nach 2 min das wirksamste Produkt. Alle Ledermixprodukte zeigten hier lediglich Reduktionen ≥1 lg Stufe. Ledermix® Fluorid Gel erzielte nach der ersten min gegenüber allen Testmikroorganismen (bis auf P. aeruginosa) die besten Ergebnisse. S. aureus war die widerstandsfähigste zu prüfende Mikroorganismenspezies und wurde um nur ≥2 lg Stufen nach mindestens 10 min Einwirkzeit der Dentalgele reduziert. Meridol® Zahnpasta war in dem geprüften Zeitraum vollständig unwirksam gegenüber S. aureus und S. mutans. Diese Zahnpasta erzielte im Vergleich zu den Gelen mit Abstand die schlechtesten Ergebnisse. Es konnte festgestellt werden, dass sich Ledermix® Fluorid Gel und Elmex®gelée insgesamt in ihrer mikrobioziden Wirksamkeit kaum unterschieden. Die mikrobiozide Wirkung der untersuchten Dentalgele ist am ehesten durch den Gehalt an Aminfluorid/Natriumfluorid zu erklären. Dabei haben das Konservierungsmittel und auch das Parfumöl einen nicht unwesentlichen Anteil an der Wirksamkeit.
Die Antiseptika-Forschung ist ein wichtiges Gebiet, aber die Testmethoden sind nur bis zur Prüfstufe des Suspensionstests einheitlich geregelt. Daher sind die Ergebnisse sich in der Testhierarchie anschließender Studien schwierig zu vergleichen und zwingen den Praktiker, Therapieentscheidungen oft auf Basis empirischer Erfahrungen zu treffen. In der vorliegenden Arbeit wurde das Verhalten verschiedener in der klinischen Praxis gebräuchlicher Antiseptika in einem Prüfkörpertest untersucht, der an die Wirksamkeit höhere Anforderungen als der klassische Suspensionstest stellt. Dabei sollte auf dem Prüfkörper zugleich eine für Wunden realitätsnahe Belastung eingesetzt werden. Für die Testung wurden Metallträger mit verschiedenen Erregersuspensionen und Belastungen kontaminiert, angetrocknet und die Wirksamkeit von PVP-Iod und Chlorhexidindigluconat bei verschiedenen Einwirkungszeiten ermittelt. Das erfolgte mit der Zielsetzung festzustellen, ob sich einer der beiden Wirkstoffe als Referenz für künftige Prüfkörpertests eignet. PVP-Iod zeigte in allen Versuchen unabhängig vom Testorganismus (S. aureus, P. aeruginosa und E. faecium) und von der verwendeten Belastung (ohne, MEM + 10 % FBS, 10 bzw. 30 % Vollblut) eine rasch einsetzende, stabile und ausreichende antiseptische Wirkung (ohne Belastung RF > 5, mit Belastung RF > 3 [Pitten et al. 2003]). Das bildete einen deutlichen Kontrast zu den mit Chlorhexidindigluconat erzielten Ergebnissen. Die mit PVP-Iod und Chlorhexidindigluconat gewonnenen Ergebnisse wurden mit den Ergebnissen einer vorangegangenen Studie [Brautferger 2010] zu Octenidindihydrochlorid und Polihexanid verglichen. Auch als Schlussfolgerung dieses Vergleiches kann PVP-Iod als Referenzsubstanz für die Antiseptikatestung empfohlen werden. Obwohl PVP-Iod in Fragen von Verträglichkeit, Remanenz etc. von den neueren Antiseptika übertroffen wird, zeigte kein anderer Wirkstoff in unseren Testungen ein vergleichbar stabiles Wirkungsverhalten. In Verbindung mit der jahrzehntelangen Erfahrung im Einsatz von PVP-Iod kann daher PVP-Iod als Referenzsubstanz für die Antiseptikatestung empfohlen werden.
In der vorliegenden Arbeit wurden Hautveränderungen unter Anwendung eines Pflegetuchs (Bag Bath) an 14 bettlägerigen Patienten über eine Woche untersucht. Zusätzlich wurden in Form eines Fragebogens die Einstellungen und Erfahrungen des Pflegepersonals in Bezug auf die Anwendung des Pflegetuches erfasst. Die Hautveränderungen der Patienten wurden über einen selbstentwickelten Handscore visuell ermittelt. Hierbei fanden die Merkmale Erythem, Rhagade, Bagatellverletzung, Erosion, Schuppung und Trockenheit Berücksichtigung. Der Parameter Trockenheit war im Trend rückläufig, was auf eine erhöhte Hautfeuchtigkeit hindeutet. Bei den übrigen Parametern konnte über den Anwendungszeitraum statistisch keine Veränderung nachgewiesen werden. Zur Objektivierung der Hautparameter wurden zusätzlich ein Cutometer zur Bestimmung der Hautelastizität, ein Reviscometer zur Messung der Schallaufzeit in der Haut, ein Sebumeter zur Bestimmung des Hautfettgehalts und ein Tewameter zur Bestimmung des transepidermalen Wasserverlusts eingesetzt. Hierbei zeigten die Messergebnisse des Reviscometers im Vergleich zur ersten und letzten Messung eine signifikant verringerte Schalllaufzeit. In den übrigen Messverfahren ließen sich statistisch keine Veränderungen nachweisen. An der Erfassung der Einstellungen und Erfahrungen des Pflegepersonals mit Hilfe des Fragebogens beteiligten sich alle Mitarbeiter (n = 30) der Anwendungsbeobachtung. Obwohl im Durchschnitt überwiegend über eine Zeitersparnis und Arbeitserleichterung berichtet wurde, stellte sich eine geringe Veränderungsbereitschaft dar, das neue Produkt in Zukunft anzuwenden. Vor dem Hintergrund aller getätigten Untersuchungen sprechen die Ergebnisse nicht für eine hautschädigende Wirkung durch die Pflegetuchanwendung innerhalb des einwöchigen Messzeitraums. Eine nachfolgende Untersuchung sollte über einen längeren Zeitraum und mit höherer Fallzahl erfolgen. Hierbei wäre es sinnvoll, auch betriebswirtschaftliche und ökologische Aspekte einzubeziehen.
Im klinischen Alltag an deutschen Kliniken spielt die Verhinderung nosokomialer Erkrankungen eine bedeutende Rolle. Infektionen mit sporenbildenden Stäbchenbakterien, besonders die durch C. difficile hervorgerufene C. difficile- assoziierte-Diarrhoe, nehmen als Folge der Antibiotikatherapie zu. Wachsende Virulenz, unvorsichtige Antibiotikaanwendung und zunehmende Multimorbidität der älteren Patienten sorgen für eine erhöhte Anfälligkeit gegenüber sporenbildende Bakterien, was zu wachsenden Problemen in der Versorgung schwerkranker und älterer Mensch führt, verbunden mit erhöhter Morbidität und Letalität. Bezüglich der Suszeptibilität von Sporenbildnern gegenüber Händedesinfektionsmitteln ist die Datenlage für praxisnahe Studien unbefriedigend. Daher wurde in der vorliegenden Studie die Wirksamkeit eines Peressigsäure basierten Desinfektionsmittels, die Kombination von Peressigsäure mit Wasserstoffperoxid, Wasserstoffperoxid allein, Poly Alcohol Hände Antisepticum sowie Kaliseife gegen Bakteriensporen verglichen. Testorganismus war Bacillus subtilis (atropheus), ein apathogener, grampositiver, stäbchenförmiger, aerob wachsender Endosporenbildner. Dem Studiendesign wurde die DIN EN 1500 in modifizierter Form zugrunde gelegt. Der wesentliche Unterschied bestand in der Verwendung steriler Probebeuteln, in denen die ganze Hand anstatt nur der Fingerkuppen zur Bestimmung des Vor- und Nachwerts bewegt wurde. Die Einwirkzeit der Desinfektionsmittel betrug 30 s. Kaliseife wurde nach 30 s Anwendung unter laufendem Wasser abgespült. Pro Präparat erfolgte die Prüfung an 15 freiwilligen Probanden im Lateinischen Quadrat. Für alle Präparate konnte keine ausreichende Wirksamkeit im Sinne einer log-Stufen-Reduktion um mindestens drei Stufen gegenüber den Bakteriensporen festgestellt werden. Es konnte nur gezeigt werden, dass Peressigsäure und Peressigsäure in Kombination mit Wasserstoffperoxid sowie Kaliseife die Kontamination am effektivsten reduzierten. Als Fazit ist die sporozide Händedesinfektion als nicht ausreichend für die Prophylaxe der Weiterverbreitung von Sporen über die Hand anzusehen, so dass die Notwendigkeit für weiterführende Untersuchungen zur Sporenelimination besteht. Als geeignete Schutzmaßnahmen ist das Tragen von Schutzhandschuhen mit nachfolgender hygienischer Händedesinfektion mit einem Peressigsäure-basierten Desinfektionsmittel zu empfehlen
Das Tragen textiler Unterziehhandschuhe ist eine Möglichkeit zur Verringerung feuchtigkeitsbedingter Hautschäden. Mit dieser Machbarkeitsstudie sollten Erfahrungen mit dem Einsatz textiler aufbereitbarer Unterziehhandschuhe im stationären Pflegebereich gesammelt und dabei insbesondere Fragen zur Logistik, Kosten, Trageeigenschaften und Akzeptanz beantwortet werden. Über drei Monate wurde auf einer Intensivpflegestation der Einsatz von Unterziehhandschuhen mit 18 Mitarbeitern getestet. Nach jedem Tragen wurden mittels Dokumentationsbogen Angaben zur Nutzung und Akzeptanz standardisiert abgefragt. Die Handschuhe wurden als Netzwäsche gemäß den Richtlinien für die Aufbereitung von Krankenhauswäsche aufbereitet und erneut zur Nutzung bereitgestellt. Während und zum Ende der Studie wurden die teilnehmenden Mitarbeiter im Rahmen einer Fragebogenerhebung ausführlich hinsichtlich ihrer Erfahrungen zur Anwendung der Baumwoll-Unterziehhandschuhe und ihrer persönlichen Beurteilung bezüglich der Trageeigenschaften befragt. Während der Studiendauer wurden 2165 Anwendungen mit einer nötigen Umlaufmenge von 687 Paar Handschuhen dokumentiert. Daraus ergab sich ein Tagesverbrauch von durchschnittlich 4 Paar pro Person. Die durchschnittliche Tragedauer betrug 28,6 min. Die Unterziehhandschuhe zeigten sich von den Trageeigenschaften und der Aufbereitbarkeit als geeignet. Die aufbereitungsbedingte Materialermüdung war gering und führte nicht zum Verlust der Trageeigenschaften; nur wenige Handschuhe mussten aussortiert werden. Bei Studienende waren noch 90,5 % der Handschuhe vorhanden und weiter einsetzbar. Die Anschaffungs- und Aufbereitungskosten betrugen für die gesamte Umlaufmenge von 687 Paar Handschuhen 973,20 Euro bzw. 0,45 Euro pro Anwendung, wenn man von einer vollständigen Abschreibung der Handschuhe mit Studienende ausgeht. Die tatsächlichen Kosten unter Einbeziehung des Restwertes der Handschuhe sind entsprechend geringer. Die Akzeptanz und Compliance zur Nutzung der Unterziehhandschuhe war bemerkenswert gut. Das lag zum einen an den Eigenschaften der Handschuhe, zum anderen an der Reduktion des Schwitzens und dem positiv empfundenen Einfluss auf die Haut der Hände. Mit der Studie konnte die Durchführbarkeit des routinemäßigen Einsatzes textiler Unterziehhandschuhe als Hautschutzmaßnahme gezeigt werden. Bei bedarfsgerechter Bereitstellung und mit entsprechender Erfahrung in der Anwendung ist die praktische Nutzung von Unterziehhandschuhen unkompliziert realisierbar. Voraussetzung sind die Aufklärung der Anwender und die Implementierung der Logistik der Aufbereitung.
Zielsetzung: Die Bereitstellung von Wasser mit Trinkwasserqualität ohne Gehalt an Trinkwasserpathogenen ist für immunsupprimierte Patienten von entscheidendem Einfluss auf die Mortalität und Letalität. Deshalb wurde in einer prospektiven Studie die Effizienz eines neu entwickelten aufbereitbaren Point-of-use Filters (Germlyser®, Aquafree GmbH, Hamburg) geprüft. Methode: Die Studie umfasste 4 Versuchsserien. In Versuchsserie 1 wurden die Filter nach einer Filterstandzeit von 7 d manuell, in Versuchsserie 2 maschinell in einem RDG aufbereitet. Nach der Aufbereitung wurden die Filter auf Leckage geprüft und in sterilen Behältern zwischengelagert. In Versuchsserie 3 wurde die Standzeit der Filter auf bzw. 4 Wochen verlängert und analog wie in Versuchsserie 2 aufbereitet. Versuchsserie 4 unterschied sich von Versuchsserie 3 durch den Einsatz eines im Gehäuse veränderten Filters und die auf 8 Wochen verlängerte Standzeit. Insgesamt wurden 12 Zapfeinrichtungen und 6 Brauseköpfe beprobt. In Versuchsserie 2 wurden 78 Proben von 6 Zapfeinrichtungen aus den Badezimmern der Patientenzimmer gezogen. Die Proben wurden jeweils direkt vor dem Filterwechsel gewonnen. Während Versuchsserie 1 mit wöchentlichem Filterwechsel über 3 Wochen durchgeführt wurde, beinhaltete Versuchsserie 2 13 Probennahmen mit jeweils wöchentlichem Filterwechsel im Verlauf von 7 Wochen, danach monatlich über 6 Monate. In Versuchsserie 3 wurden die Proben bei monatlichem Filterwechsel wöchentlich über 3 Monate gesammelt und in Versuchsserie 4 bei Filterwechsel nach 2 Monaten nach 2, 4 und 8 Wochen. Zur Probennahme wurde die erste auslaufende Wasserportion ohne vorheriges Abflammen des Wasserauslasses in einem sterilen Probennahmegefäß aufgefangen. Untersucht wurde auf Gesamtkoloniezahl bei 22 und 36 °C, coliforme Bakterien, P. aeruginosa, Fäkalstreptokokken, Legionella spp. und Schimmelpilze entsprechend Anlage 1 Nr. 5 der TrinkwV (1990), DIN EN 12780, der Empfehlung des Umweltbundesamts (2000) sowie gemäß Daeschlein et al. (2008). Ergebnisse: Während die manuelle Aufbereitung zur Verkeimung der Filter führte, gewährleistete die maschinelle Aufbereitung die sichere Dekontamination der Filter. Das gefilterte Wasser erfüllte die Anforderungen der Deutschen TrinkwV ebenso wie der die WHO Leitlinie, d. h. kein Nachweis von Wasserpathogenen und Koloniezahl < 100/ml. Die Wiederaufbereitungsintervalle konnten von 1 bis auf 8 Wochen ausgedehnt werden.