Refine
Year of publication
Document Type
- Article (30)
- Doctoral Thesis (3)
Language
- English (33) (remove)
Has Fulltext
- yes (33)
Is part of the Bibliography
- no (33)
Keywords
- - (24)
- plasma medicine (4)
- reactive oxygen and nitrogen species (3)
- Octenidine dihydrochloride (2)
- Polihexanide (2)
- RNS (2)
- ROS (2)
- Skin barrier (2)
- antibiotics (2)
- antiseptic stewardship (2)
- biocide (2)
- cancer (2)
- cold physical plasma (2)
- cross-resistance (2)
- cross-tolerance (2)
- 2-Phenoxyethanol (1)
- Absorption (1)
- Antimicrobial (1)
- Antimicrobial efficacy (1)
- Antioxidants (1)
- Antisepsis (1)
- Antiseptic (1)
- Antiseptic efficacy (1)
- Antiseptic mouth rinse (1)
- Antiseptics (1)
- Antiseptikum (1)
- Atmospheric pressure plasma (1)
- Bacteria (1)
- Bacterial vaginosis (1)
- Biatain Ag (1)
- Biocidal product regulation (1)
- Biofilm (1)
- Blood supply (1)
- CAP (1)
- COVID-19 (1)
- Chlorhexidine digluconate (1)
- Cytokine secretion (1)
- Demographic change (1)
- Dielectric barrier discharge (1)
- Energy supply (1)
- Epidemiologie (1)
- Ethanol based hand rub (1)
- Fungi (1)
- Genital tract infection (1)
- Granudacyn® (1)
- Hair follicle (1)
- Hand antisepsis (1)
- Hospitalismus <Hygiene> (1)
- Human papilloma virus (1)
- Hypochlorous acid (1)
- Implant surface (1)
- In vivo laser scanning microscopy (1)
- Inactivation (1)
- Kaltes Plasma (1)
- Melanom (1)
- Memorandum (1)
- Mitochondrium (1)
- Molecular dynamics simulation (1)
- Mucositis (1)
- Non-enveloped viruses (1)
- Octenidine dihydrochlorid (1)
- Octenidol® md (1)
- Oxygen supply (1)
- PEF (1)
- PHMB (1)
- PHMB adsorption (1)
- Patient safety (1)
- Plasma treatment in vivo (1)
- Poly (hexamethylene biguanide) hydrochloride (PHMB) (1)
- Poly(hexamethylene)biguanide (1)
- Polyhexamethylene biguanide (1)
- RNA (1)
- Reconstructed human epidermis (1)
- Red blood cell concentrates (1)
- Residual antimicrobial effect (1)
- Risk–benefit-assessment (1)
- Rose Bengal staining (1)
- SARS-CoV-2 (1)
- SKH1 mouse model (1)
- SR101 (1)
- SaOs‐2 cell differentiation (1)
- Silver wound dressing (1)
- Sodium hypochlorite (1)
- Stratum corneum (1)
- Suction blister (1)
- Suction blister technique (1)
- Surface barrier discharge plasma source (1)
- TEER (1)
- THP-1 macrophages (1)
- Ti6Al4V (1)
- Ti6Al4V alloy (1)
- TiO2 (1)
- Transepidermal water loss (1)
- UVA-LED (1)
- UVA-responsive (1)
- VUV radiation (1)
- WHO (1)
- Wasserhygiene (1)
- Wassersicherheitsplan (1)
- Water-filtered infrared-A radiation (1)
- Worker safety (1)
- Wound (1)
- Wound antiseptics, HET-CAM, irritation score, octenidine, chlorhexidine, polihexanide, hypochlorite, hydrogen peroxide, hemoglobin spray, allantoin, dexpanthenol, thiocyanate. (1)
- Wound at risk of infection (1)
- Wound at risk score (W.A.R. score) (1)
- Wound colonization (1)
- Wound healing (1)
- Wound management (1)
- Wound secretion (1)
- antimicrobial (1)
- antimicrobial activity (1)
- antimicrobial coating (1)
- antiseptics (1)
- atmospheric pressure (1)
- carbon contamination (1)
- chronic wound (1)
- chronic wounds (1)
- cold atmospheric pressure plasma (1)
- cold atmospheric pressure plasma (CAP) (1)
- confocal laser scanning microscopy (1)
- contact killing surface (1)
- contamination (1)
- cytotoxicity (1)
- decontamination (1)
- dermal full-thickness wounds (1)
- diabetic foot (1)
- dynamic light scattering (1)
- hair follicles (1)
- hydrogen peroxide (1)
- hydroxyethyl starch (1)
- hypochlorous acid (1)
- implant coating (1)
- inductively-limited discharge (1)
- infected wounds (1)
- infectious virus (1)
- ion chromatography (1)
- kINPen (1)
- kINPen plasma jet (1)
- kINpen (1)
- low temperature plasma (1)
- macaques (1)
- micelle (1)
- microwave (1)
- moDCs (1)
- mouth rinse (1)
- mucosa model (1)
- mucositis (1)
- multidrug-resistant microorganisms (1)
- nanocapsules (1)
- nitrate (1)
- nitrite (1)
- non-thermal plasma (1)
- osseointegration (1)
- peroxynitrite (1)
- plasma discharge (1)
- plasma-treated water (1)
- porcine skin model (1)
- reactive oxygen species (1)
- reactive species (1)
- redox biology (1)
- redox signaling (1)
- risk evaluation (1)
- source of transmission (1)
- surface (1)
- surface modification (1)
- tap water (1)
- tape stripping model (1)
- titanium alloys (1)
- treatment control (1)
- vaccine (1)
- viral load (1)
- water contact angle (1)
- water safety plan (1)
- wetting (1)
- wound healing (1)
Institute
- Institut für Hygiene und Umweltmedizin (33) (remove)
Publisher
- MDPI (14)
- S. Karger AG (10)
- BioMed Central (BMC) (3)
- Frontiers Media S.A. (1)
- IOP Publishing (1)
- Wiley (1)
Oral mucositis is the most common and severe non-hematological complication associated with cancer radiotherapy, chemotherapy, or their combination. Treatment of oral mucositis focuses on pain management and the use of natural anti-inflammatory, sometimes weakly antiseptic mouth rinses in combination with optimal oral cavity hygiene. To prevent negative effects of rinsing, accurate testing of oral care products is necessary. Due to their ability to mimic realistic in-vivo conditions, 3D models may be an appropriate option in compatibility testing of anti-inflammatory and antiseptically effective mouth rinses. We present a 3D model of oral mucosa based on the cell line TR-146 with a physical barrier, characterized by high transepithelial electrical resistance (TEER) and confirmed cell integrity. Histological characterization of the 3D mucosa model showed a stratified, non-keratinized multilayer of epithelial cells similar to that of human oral mucosa. By means of immuno-staining, tissue-specific expression of cytokeratin 13 and 14 was shown. Incubation of the 3D mucosa model with the rinses had no effects on cell viability, but TEER decreased 24h after incubation in all solutions except ProntOral®. Analogous to skin models, the established 3D model meets the quality control criteria of OECD guidelines and may therefore be suitable for comparing the cytocompatibility of oral rinses.
Aim
Periprosthetic joint infections are a devastating complication after arthroplasty, leading to rejection of the prosthesis. The prevention of septic loosening may be possible by an antimicrobial coating of the implant surface. Poly (hexamethylene) biguanide hydrochloride [PHMB] seems to be a suitable antiseptic agent for this purpose since previous studies revealed a low cytotoxicity and a long-lasting microbicidal effect of Ti6Al4V alloy coated with PHMB. To preclude an excessive activation of the immune system, possible inflammatory effects on macrophages upon contact with PHMB-coated surfaces alone and after killing of S. epidermidis and P. aeruginosa are analyzed.
Methods
THP-1 monocytes were differentiated to M0 macrophages by phorbol 12-myristate 13-acetate and seeded onto Ti6Al4V surfaces coated with various amounts of PHMB. Next to microscopic immunofluorescence analysis of labeled macrophages after adhesion on the coated surface, measurement of intracellular reactive oxygen species and analysis of cytokine secretion at different time points without and with previous bacterial contamination were conducted.
Results
No influence on morphology of macrophages and only slight increases in iROS generation were detected. The cytokine secretion pattern depends on the surface treatment procedure and the amount of adsorbed PHMB. The PHMB coating resulted in a high reduction of viable bacteria, resulting in no significant differences in cytokine secretion as reaction to coated surfaces with and without bacterial burden.
Conclusion
Ti6Al4V specimens after alkaline treatment followed by coating with 5–7 μg PHMB and specimens treated with H2O2 before PHMB-coating (4 μg) had the smallest influence on the macrophage phienotype and thus are considered as the surface with the best cytocompatibility to macrophages tested in the present study.
Unlike the native surface of the implant material (Ti6Al4V), oxidation with H2O2 leads to increased binding of the effective antimicrobial agent poly(hexamethylene) biguanide [PHMB]. However, treating with NaOH instead results in an even higher PHMB mass coverage. After oxidation with H2O2, strong differences in the PHMB adsorption capability between polished and corundum-blasted surfaces appear, indicating a roughness dependence. After NaOH treatment, no such effect was observed. The wetting properties of specimens treated with either H2O2 or NaOH prior to PHMB exposure clearly varied. To unravel the nature of this interaction, widespread in silico and in vitro experiments were performed. Methods: By X-ray photoelectron spectroscopy, scanning electron microscopy, water contact angle measurements and MD simulations, we characterized the interplay between the polycationic antimicrobial agent and the implant surface. A theoretical model for PHMB micelles is tested for its wetting properties and compared to carbon contaminated TiO2. In addition, quantitation of anionic functional group equivalents, the binding properties of PHMB with blocked amino end-group, and the ability to bind chlorhexidine digluconate (CHG) were investigated. Ultimately, the capability of osteoblasts to build calcium apatite, and the activity of alkaline phosphatase on PHMB coated specimens, were determined. Results: Simulated water contact angles on carbon contaminated TiO2 surfaces and PHMB micelle models reveal little influence of PHMB on the wetting properties and point out the major influence of remaining and recovering contamination from ambient air. Testing PHMB adsorption beyond the critical micelle concentration and subsequent staining reveals an island-like pattern with H2O2 as compared to an evenly modified surface with NaOH. Both CHG and PHMB, with blocked amino end groups, were adsorbed on the treated surfaces, thus negating the significant influence of PHMB’s terminal groups. The ability of osteoblasts to produce calcium apatite and alkaline phosphatase is not negatively impaired for PHMB mass coverages up to 8 μg/specimen. Conclusion: Differences in PHMB adsorption are triggered by the number of anionic groups and carbon contaminants, both of which depend on the specimen pre-treatment. With more PHMB covering, the implant surface is protected against the capture of new contamination from the ambient air, thus building a robust antimicrobial and biocompatible surface coating.
Objectives
Oral mucositis caused by intensive cancer chemotherapy or radiotherapy frequently results in pronounced damage of the oral mucosa leading to painful oral hygiene. To support oral care, antimicrobial effective mouth rinses may be used. Thus, the efficacy of a hypochlorite-based mouth rinse (Granudacyn®), assumed to be highly biocompatible because of the compounds being part of the natural pathogen defense, as possible antiseptic agent in case of oral mucositis was compared to that of an octenidine based antiseptic mouth rinse (Octenidol® md).
Materials and methods
The study was conducted as monocentric, controlled, randomized, blind cross over comparative study on 20 volunteers. As a proof of principle, we performed the study on orally healthy subjects and not cancer patients. The efficacy was determined as reduction of colony forming units (cfu) on buccal mucosa as well as in saliva. After mouth rinsing for 30 s, samples were taken after 1 min, 15 min, 30 and 60 min. The lg-reduction was calculated as difference between lg-values of cfu pre- and post-treatment.
Results
Both antiseptic mouth rinses induced a significant reduction of cfu on buccal mucosa and in saliva 1 min after mouth rinsing. The effect persisted up to 60 min. The octenidine based rinse was significantly superior to the hypochlorite-based rinse up to the last sample 60 min after rinsing. However, the known cytotoxicity of octenidine argues against its application.
Conclusion
Within the limits of this study, due to its antiseptic efficacy, the hypochlorite-based rinse Granudacyn® can be regarded appropriate to support the oral hygiene in patients with a sensitive oral mucosa during an aggressive cancer chemotherapy and radiation treatment in case of oral mucositis.
AbstractPlasma medicine refers to the application of nonequilibrium plasmas at approximately body temperature, for therapeutic purposes. Nonequilibrium plasmas are weakly ionized gases which contain charged and neutral species and electric fields, and emit radiation, particularly in the visible and ultraviolet range. Medically-relevant cold atmospheric pressure plasma (CAP) sources and devices are usually dielectric barrier discharges and nonequilibrium atmospheric pressure plasma jets. Plasma diagnostic methods and modelling approaches are used to characterize the densities and fluxes of active plasma species and their interaction with surrounding matter. In addition to the direct application of plasma onto living tissue, the treatment of liquids like water or physiological saline by a CAP source is performed in order to study specific biological activities. A basic understanding of the interaction between plasma and liquids and bio-interfaces is essential to follow biological plasma effects. Charged species, metastable species, and other atomic and molecular reactive species first produced in the main plasma ignition are transported to the discharge afterglow to finally be exposed to the biological targets. Contact with these liquid-dominated bio-interfaces generates other secondary reactive oxygen and nitrogen species (ROS, RNS). Both ROS and RNS possess strong oxidative properties and can trigger redox-related signalling pathways in cells and tissue, leading to various impacts of therapeutic relevance. Dependent on the intensity of plasma exposure, redox balance in cells can be influenced in a way that oxidative eustress leads to stimulation of cellular processes or oxidative distress leads to cell death. Currently, clinical CAP application is realized mainly in wound healing. The use of plasma in cancer treatment (i.e. plasma oncology) is a currently emerging field of research. Future perspectives and challenges in plasma medicine are mainly directed towards the control and optimization of CAP devices, to broaden and establish its medical applications, and to open up new plasma-based therapies in medicine.
Background: Annual transfusion rates in many European countries range between 25 and 35 red blood cell concentrates (RBCs)/1,000 population.It is unclear why transfusion rates in Germany are considerably higher (approx. 50–55 RBCs/1,000 population). Methods: We assessed the characteristics of transfusion recipients at all hospitals of the German federal state Mecklenburg-Western Pomerania during a 10-year longitudinal study. Results: Although 75% of patients received ≤4 RBCs/patient in 2015 (1 RBC: 11.3%; 2 RBCs: 42.6%; 3 RBCs: 6.3%; 4 RBCs: 15.0%), the mean transfusion index was 4.6 RBCs due to a minority of patients with a high transfusion demand. Two thirds of all RBCs were transfused to only 25% of RBC recipients. Consistently, male patients received a higher number of RBCs (2005: 54.2%; 2015: 56.8%) and had a higher mean transfusion index than female patients (mean 5.1 ± 7.2; median 2; inter-quartile range [IQR] 2–4 vs. mean 4.0 ± 5.8; median 2; IQR 2–4). The absolute transfusion demand decreased between 2005 and 2015 by 13.5% due to a composite of active reduction (clinical practice change) and population decline in the 65- to 75-year age group (lower birth rate cohort 1940–1950); however, with major differences between hospitals (range from –61.0 to +41.4%). Conclusion: Transfusion demand in a population could largely be driven by patients with high transfusion demand. Different treatment practices in this group of patients probably add to the major differences in transfusion demand per 1,000 individuals between countries. The available data cannot prove this hypothesis. Implementation of a diagnosis-related group-based monitoring system is urgently needed to allow informative monitoring on the population level and meaningful comparisons between transfusion practices.
Multiple evidence in animal models and in humans suggest a beneficial role of cold physical
plasma in wound treatment. Yet, risk assessment studies are important to further foster therapeutic
advancement and acceptance of cold plasma in clinics. Accordingly, we investigated the long-term
side effects of repetitive plasma treatment over 14 consecutive days in a rodent full-thickness ear
wound model. Subsequently, animals were housed for 350 days and sacrificed thereafter. In blood,
systemic changes of the pro-inflammatory cytokines interleukin 1β and tumor necrosis factor α
were absent. Similarly, tumor marker levels of α-fetoprotein and calcitonin remained unchanged.
Using quantitative PCR, the expression levels of several cytokines and tumor markers in liver,
lung, and skin were found to be similar in the control and treatment group as well. Likewise,
histological and immunohistochemical analysis failed to detect abnormal morphological changes
and the presence of tumor markers such as carcinoembryonic antigen, α-fetoprotein, or the neighbor
of Punc 11. Absence of neoplastic lesions was confirmed by non-invasive imaging methods such as
anatomical magnetic resonance imaging and positron emission tomography-computed tomography.
Our results suggest that the beneficial effects of cold plasma in wound healing come without apparent
side effects including tumor formation or chronic inflammation.
The objective of the present investigation was to examine the residual antimicrobial activity after a topical exposure of reconstructed human epidermis (RHE) to equimolar solutions of either chlorhexidine digluconate (CHG, 0.144% w/v) or octenidine dihydrochloride (OCT, 0.1% w/v) for 15 min. RHE-associated antiseptic agents were more effective on Staphylococcus aureus than on Pseudomonas aeruginosa. S. aureus was not detected after 24 h of contact, which demonstrated a microbicidal efficacy of greater than 5-log<sub>10</sub> reduction. In contrast, P. aeruginosa was reduced by approximately 2 log<sub>10</sub> at the same incubation time, which parallels the growth of the initial inoculum. This result could be interpreted either as a microbiostatic effect or as an adherence of P. aeruginosa to a low positively charged surface. Small amounts of CHG and OCT can penetrate the stratum corneum. Using these antiseptic agents, the viability of keratinocytes was reduced to 65-75% of that of the untreated RHE control following 24 h incubation in the presence of test microorganisms. With consideration of antimicrobial activity and cytotoxic effect, OCT corresponds better to a biocompatible antiseptic agent than CHG.
There has been a substantial evolution of anti-cancer therapies in the last decade, leading
to improved prognosis and disease-free survival of patients with melanoma. Due to the
number of patients that still develop resistance or to the high systemic toxicity and side
effects, new treatment options are still needed. Regardless of the type of therapeutic
interventions (except surgery), the reactive oxygen species (ROS) are a by-product or
contribute to the action mechanism of many successful therapies. In this context, medical
cold atmospheric plasma (CAP) arises as a promising tool, and studies are important to
prove the effectiveness of this new device.
Since combination therapies are the current standard way to treat melanoma, we explored
candidates to be combined with cold atmospheric plasma, with potential to become a
therapeutic option in the combination. Here, we tested the radiotherapy and clinically safe
mitochondrial inhibitor drugs. In the end of the study, both, ionizing radiation and four
mitochondrial-targeted-drugs showed to be promising candidates for the combination with
CAP. These combinations induced increased cytotoxicity and modulated the immune
system improving the anti-tumor immune response. Mitochondrial damage seems to be
the first stage to induce cellular deficiency and culminate in apoptotic cell death.
Furthermore the release of GM-CSF contribute to a pro inflammatory state and immune
system activation.
This dissertation showed that CAP serves as an excellent tool to boost melanoma cell
death and induce anti-tumor response. In addition, in our proposed therapeutic
combination, the intensity of plasma treatment could be decreased possibly resulting in
less systemic toxicity. Our results serves as model to be studied in other tumor entities.
Because of its antimicrobial properties, nonthermal plasma could serve as an alternative to chemical antisepsis in wound treatment. Therefore, this study investigated the inactivation of biofilm-embedded Pseudomonas aeruginosa SG81 by a surface barrier-discharged (SBD) plasma for 30, 60, 150 and 300 s. In order to optimize the efficacy of the plasma, different carrier gases (argon, argon admixed with 1% oxygen, and argon with increased humidity up to approx. 80%) were tested and compared against 0.1% chlorhexidine digluconate (CHG) exposure for 600 s. The antimicrobial efficacy was determined by calculating the difference between the numbers of colony-forming units (CFU) of treated and untreated biofilms. Living bacteria were distinguished from dead by fluorescent staining and confocal laser scanning microscopy. Both SBD plasmas and CHG showed significant antimicrobial effects compared to the untreated control. However, plasma treatment led to a higher antimicrobial reduction (argon plasma 4.9 log<sub>10</sub> CFU/cm<sup>2</sup>, argon with admixed oxygen 3 log<sub>10</sub> CFU/cm<sup>2</sup>, and with increased gas humidity 2.7 log<sub>10</sub> CFU/cm<sup>2</sup> after 300 s) compared to CHG. In conclusion, SBD plasma is suitable as an alternative to CHG for inactivation of Pseudomonas aeruginosa embedded in biofilm. Further development of SBD plasma sources and research on the role of carrier gases and humidity may allow their clinical application for wound management in the future.
Wound healing disorders frequently occur due to biofilm formation on wound surfaces requiring conscientious wound hygiene. Often, the application of conventional liquid antiseptics is not sufficient and sustainable as (1) the borders and the surrounding of chronic wounds frequently consist of sclerotic skin, impeding an effectual penetration of these products, and (2) the hair follicles representing the reservoir for bacterial recolonization of skin surfaces are not affected. Recently, it has been reported that tissue-tolerable plasma (TTP), which is used at a temperature range between 35 and 45°C, likewise has disinfecting properties. In the present study, the effectivity of TTP and a standard liquid antiseptic was compared in vitro on porcine skin. The results revealed that TTP was able to reduce the bacterial load by 94%, although the application of the liquid antiseptic remained superior as it reduced the bacteria by almost 99%. For in vivo application, however, TTP offers several advantages. On the one hand, TTP enables the treatment of sclerotic skin as well, and on the other hand, a sustainable disinfection can be realized as, obviously, also the follicular reservoir is affected by TTP.
Colonization and infection of wounds represent a major reason for the impairment of tissue repair. Recently, it has been reported that tissue-tolerable plasma (TTP) is highly efficient in the reduction of the bacterial load of the skin. In the present study, the antiseptic efficacy of TTP was compared to that of octenidine hydrochloride with 2-phenoxyethanol. Both antiseptic methods proved to be highly efficient. Cutaneous treatment of the skin with octenidine hydrochloride and 2-phenoxyethanol leads to a 99% elimination of the bacteria, and 74% elimination is achieved by TTP treatment. Technical challenges with an early prototype TTP device could be held responsible for the slightly reduced antiseptic properties of TTP, compared to a standard antiseptic solution, since the manual treatment of the skin surface with a small beam of the TTP device might have led to an incomplete coverage of the treated area.
Background
The approval of ethanol by the Biocidal Products Regulation has been under evaluation since 2007. This follows concern over alcohol uptake from ethanol-based hand rubs (EBHR). If ethanol is classified as carcinogenic, mutagenic, or reprotoxic by the European Chemicals Agency (ECHA), then this would affect infection prevention and control practices.
Aim
A review was performed to prove that ethanol is toxicological uncritical and indispensable for hand antisepsis because of its unique activity against non-enveloped viruses and thus the resulting lack of alternatives. Therefore, the following main points are analyzed: The effectiveness of ethanol in hand hygiene, the evidence of ethanol at blood/tissue levels through hand hygiene in healthcare, and the evidence of toxicity of different blood/tissue ethanol levels and the non-comparability with alcoholic consumption and industrial exposure.
Results
EBHR are essential for preventing infections caused by non-enveloped viruses, especially in healthcare, nursing homes, food industry and other areas. Propanols are effective against enveloped viruses as opposed to non-enveloped viruses but there are no other alternatives for virucidal hand antisepsis. Long-term ingestion of ethanol in the form of alcoholic beverages can cause tumours. However, lifetime exposure to ethanol from occupational exposure < 500 ppm does not significantly contribute to the cancer risk. Mutagenic effects were observed only at doses within the toxic range in animal studies. While reprotoxicity is linked with abuse of alcoholic beverages, there is no epidemiological evidence for this from EBHR use in healthcare facilities or from products containing ethanol in non-healthcare settings.
Conclusion
The body of evidence shows EBHRs have strong efficacy in killing non-enveloped viruses, whereas 1-propanol and 2-propanol do not kill non-enveloped viruses, that pose significant risk of infection. Ethanol absorbed through the skin during hand hygiene is similar to consumption of beverages with hidden ethanol content (< 0.5% v/v), such as apple juice or kefir. There is no risk of carcinogenicity, mutagenicity or reprotoxicity from repeated use of EBHR. Hence, the WHO Task Force strongly recommend retaining ethanol as an essential constituent in hand rubs for healthcare.
Background: In clinical practice, treatment of genital tract infections is based on administration of either antibiotics or antiseptics. While antibiotics may be applied systemically or topically, antiseptics may be applied only topically. In case of bacterial vaginosis (BV), antibiotic therapy may often be limited and side effects due to systemic administration may develop. Polihexanide (PHMB) is a promising option for the topical treatment of genital tract infections, in particular BV and vaginitis. Method: A systematic search for publications on the use of PHMB for the treatment of genital infections in two electronic databases was performed. Titles, abstracts and citations were imported into a reference database. Duplicates were removed and two reviewers assessed each identified publication separately. Results: Among a total of 204 references, 3 prospective randomized trials were identified. Two trials treated BV infections with PHMB in comparison to clindamycin as antibiotic standard therapy with no significant differences either in safety or in efficacy. The third controlled trial investigated the clinical efficacy of PHMB compared to placebo in the treatment of human papilloma virus. Patients treated with PHMB daily for up to 16-weeks showed significantly higher (52%) clearance of genital warts as compared to patients treated with placebo (4%). Conclusion: PHMB may be a clinically effective alternative for the treatment of BV and human papilloma virus. Although PHMB-based antiseptics are available since the late 90s, controlled trials to investigate its clinical potential for antiseptic treatment are scant. Clinical use of antiseptics for the treatment of infectious diseases should be explored and supported further.
Contaminated surfaces have been discussed as a possible source of severe acute respiratory
syndrome coronavirus-2 (SARS-CoV-2). Under experimental conditions, SARS-CoV-2 can remain
infectious on surfaces for several days. However, the frequency of SARS-CoV-2 detection on surfaces
in healthcare settings and the public is currently not known. A systematic literature review was
performed. On surfaces around COVID-19 cases in healthcare settings (42 studies), the SARS-CoV2 RNA detection rates mostly were between 0% and 27% (Ct values mostly > 30). Detection of
infectious SARS-CoV-2 was only successful in one of seven studies in 9.2% of 76 samples. Most of the
positive samples were obtained next to a patient with frequent sputum spitting during sampling.
Eight studies were found with data from public surfaces and RNA detection rates between 0% and
22.1% (Ct values mostly > 30). Detection of infectious virus was not attempted. Similar results
were found in samples from surfaces around confirmed COVID-19 cases in non-healthcare settings
(7 studies) and from personal protective equipment (10 studies). Therefore, it seems plausible to
assume that inanimate surfaces are not a relevant source for transmission of SARS-CoV-2. In public
settings, the associated risks of regular surface disinfection probably outweigh the expectable health
benefit