Refine
Year of publication
Document Type
- Article (30)
- Doctoral Thesis (3)
Language
- English (33) (remove)
Has Fulltext
- yes (33)
Is part of the Bibliography
- no (33)
Keywords
- - (24)
- plasma medicine (4)
- reactive oxygen and nitrogen species (3)
- Octenidine dihydrochloride (2)
- Polihexanide (2)
- RNS (2)
- ROS (2)
- Skin barrier (2)
- antibiotics (2)
- antiseptic stewardship (2)
Institute
- Institut für Hygiene und Umweltmedizin (33) (remove)
Publisher
- MDPI (14)
- S. Karger AG (10)
- BioMed Central (BMC) (3)
- Frontiers Media S.A. (1)
- IOP Publishing (1)
- Wiley (1)
Background: Due to the high number of immunosuppressed and other predisposed patients hospitals have to control and ensure the microbiological water quality. The origin for the occurrence of pathogenic microorganisms in water pipes is the formation of biofilm. Methods: For the permanent control of water safety a water safety plan (WSP) was realized as recommended by the WHO following the principle "search and destroy". The WSP is based on an established HACCP concept due to the special focus. The most important measures include the concept for sample taking depending on patient risk. 3 different categories) are distinguished: risk area1 (high infection risk), risk 2 (moderate infection risk), and risk area 3 (not increased infection risk). Additionally to the threshold value of the German law for the quality of drinking water (TrinkwV) three more limiting values were defined (warning, alert, and worst case) for immediate risk adapted reaction. Additional attention has to be focussed on lavatory sinks, which are an open bacterial reservoir. Therefore continuous disinfecting siphons were installed as part of the WSP in high risk areas. If extended technical equipment is not available, especially for immunocompromised patients the following measures are easy to realize: boiled (or sun exposed) water for nursing procedures as well alimentary use, no showering. Results: Comparing data over 3 years the microbial water quality was significantly improved resulting in no new case of nosocomial Legionella pneumoniae and decrease in neonatal sepsis. Conclusion: According to average situations with highly contaminated water system the management must be defined with implementation of water task force, immediate providing of special equipment, information of patients and staff and control of the water quality, an example for successful decontamination of the hospital within 24 hours is given.
Aim: The efficacy of antimicrobial compounds included in wound dressings has been determined using the quantitative suspension test according to EN 13727 before. However, as suspension tests are not an accurate reflection of the conditions under which wound antiseptics are used, it was investigated if a disc carrier test would yield results simulating practical conditions on wound surfaces. A silver-leaching foam wound dressing was used for evaluation of the disc carrier test method. Method: The disc carriers consisted of circular stainless-steel discs measuring 2 cm in diameter and 1.5 mm in thickness, complying with the requirements of EN 10088-2. Carriers were contaminated with Staphylococcus aureus, methicillin-resistant S. aureus or Pseudomonas aeruginosa, respectively, together with an artificial wound secretion and left to dry at room temperature for 30 min. The wound dressings being tested were placed on the discs for the length of the exposure time, and after neutralization by thioglycolate in phosphate-buffered saline the number of surviving test organisms was then counted. The logarithmic reduction factor was calculated from the difference between the initial inoculum and the number of recovered test organisms. Results: The disc carrier test allowed determination of an antimicrobial efficacy in a realistic setting. It also imposed more stringent requirements on efficacy over time than the quantitative suspension test. The silver foam wound dressing showed a time-dependent antimicrobial efficacy. After 24-hour application time, the reduction factors against S. aureus, P. aeruginosa and the methicillin-resistant S. aureus were 1.9 ± 0.15, 2.1 ± 0.14 and 3.1 ± 0.18, respectively. Conclusion: The disc carrier test was a useful method for testing the antimicrobial efficacy of a foam silver dressing. The antimicrobial dressing exhibited an antimicrobial effect after 3 h and achieved a reduction >2 log against the tested bacterial strains in the presence of a simulated wound secretion after 24 h.
The effect of water-filtered infrared-A radiation (wIRA) on normal skin flora was investigated by generating experimental wounds on the forearms of volunteers utilizing the suction blister technique. Over 7 days, recolonization was monitored parallel to wound healing. Four groups of treatment were compared: no therapy (A), dexpanthenol cream once daily (B), 20 min wIRA irradiation at 30 cm distance (C), and wIRA irradiation for 30 min once daily together with dexpanthenol cream once daily (D). All treatments strongly inhibited the recolonization of the wounds. Whereas dexpanthenol completely suppressed recolonization over the test period, recolonization after wIRA without (C) and in combination with dexpanthenol (D) was suppressed, but started on day 5 with considerably higher amounts after the combination treatment (D). Whereas the consequence without treatment (A) was an increasing amount of physiological skin flora including coagulase-negative staphylococci, all treatments (B–D) led to a reduction in physiological skin flora, including coagulase-negative staphylococci. In healthy volunteers, wIRA alone and in combination with dexpanthenol strongly inhibited bacterial recolonization with physiological skin flora after artificial wound setting using a suction-blister wound model. This could support the beneficial effects of wIRA in the promotion of wound healing.
The exact qualitative and quantitative analysis of wound healing processes is a decisive prerequisite for optimizing wound care and for therapy control. Transepidermal water loss (TEWL) measurements are considered to be the standard procedure for assessing the progress of epidermal wound healing. The damage to the stratum corneum correlates with an increased loss of water through the skin barrier. This method is highly susceptible to failure by environmental factors, in particular by temperature and moisture. This study was aimed at comparing TEWL measurements and in vivo laser scanning microscopy (LSM) for the characterization of the epidermal wound healing process. LSM is a high-resolution in vivo method permitting to analyze the kinetics and dynamics of wound healing at a cellular level. While the TEWL values for the individual volunteers showed a wide scattering, LSM permitted the wound healing process to be clearly characterized at the cellular level. However, a comparison between the two methods was very difficult, because the results provided by LSM were images and not numerical. Therefore, a scoring system was set up which evaluates the stages of wound healing. Thus, the healing process could be numerically described. This method is independent of any environmental factors. Providing morphologically qualitative and numerically quantitative analyses of the wound healing process and being far less vulnerable to failure, LSM is advantageous over TEWL.
Wound healing disorders frequently occur due to biofilm formation on wound surfaces requiring conscientious wound hygiene. Often, the application of conventional liquid antiseptics is not sufficient and sustainable as (1) the borders and the surrounding of chronic wounds frequently consist of sclerotic skin, impeding an effectual penetration of these products, and (2) the hair follicles representing the reservoir for bacterial recolonization of skin surfaces are not affected. Recently, it has been reported that tissue-tolerable plasma (TTP), which is used at a temperature range between 35 and 45°C, likewise has disinfecting properties. In the present study, the effectivity of TTP and a standard liquid antiseptic was compared in vitro on porcine skin. The results revealed that TTP was able to reduce the bacterial load by 94%, although the application of the liquid antiseptic remained superior as it reduced the bacteria by almost 99%. For in vivo application, however, TTP offers several advantages. On the one hand, TTP enables the treatment of sclerotic skin as well, and on the other hand, a sustainable disinfection can be realized as, obviously, also the follicular reservoir is affected by TTP.
Currently, there are no generally accepted definitions for wounds at risk of infection. In clinical practice, too many chronic wounds are regarded as being at risk of infection, and therefore many topical antimicrobials – in terms of frequency and duration of use – are applied to wounds. Based on expert discussion and current knowledge, a clinical assessment score was developed. The objective of this wounds at risk (W.A.R.) score is to allow decision-making on the indication for the use of antiseptics on the basis of polihexanide. The proposed clinical classification of W.A.R. shall facilitate the decision for wound antisepsis and allow an appropriate general treatment regimen with the focus on the prevention of wound infection. The W.A.R. score is based on a clinically oriented risk assessment using concrete patient circumstances. The indication for the use of antiseptics results from the addition of differently weighted risk causes, for which points are assigned. Antimicrobial treatment is justified in the case of 3 or more points.
Background: In clinical practice, treatment of genital tract infections is based on administration of either antibiotics or antiseptics. While antibiotics may be applied systemically or topically, antiseptics may be applied only topically. In case of bacterial vaginosis (BV), antibiotic therapy may often be limited and side effects due to systemic administration may develop. Polihexanide (PHMB) is a promising option for the topical treatment of genital tract infections, in particular BV and vaginitis. Method: A systematic search for publications on the use of PHMB for the treatment of genital infections in two electronic databases was performed. Titles, abstracts and citations were imported into a reference database. Duplicates were removed and two reviewers assessed each identified publication separately. Results: Among a total of 204 references, 3 prospective randomized trials were identified. Two trials treated BV infections with PHMB in comparison to clindamycin as antibiotic standard therapy with no significant differences either in safety or in efficacy. The third controlled trial investigated the clinical efficacy of PHMB compared to placebo in the treatment of human papilloma virus. Patients treated with PHMB daily for up to 16-weeks showed significantly higher (52%) clearance of genital warts as compared to patients treated with placebo (4%). Conclusion: PHMB may be a clinically effective alternative for the treatment of BV and human papilloma virus. Although PHMB-based antiseptics are available since the late 90s, controlled trials to investigate its clinical potential for antiseptic treatment are scant. Clinical use of antiseptics for the treatment of infectious diseases should be explored and supported further.
Colonization and infection of wounds represent a major reason for the impairment of tissue repair. Recently, it has been reported that tissue-tolerable plasma (TTP) is highly efficient in the reduction of the bacterial load of the skin. In the present study, the antiseptic efficacy of TTP was compared to that of octenidine hydrochloride with 2-phenoxyethanol. Both antiseptic methods proved to be highly efficient. Cutaneous treatment of the skin with octenidine hydrochloride and 2-phenoxyethanol leads to a 99% elimination of the bacteria, and 74% elimination is achieved by TTP treatment. Technical challenges with an early prototype TTP device could be held responsible for the slightly reduced antiseptic properties of TTP, compared to a standard antiseptic solution, since the manual treatment of the skin surface with a small beam of the TTP device might have led to an incomplete coverage of the treated area.
The objective of the present investigation was to examine the residual antimicrobial activity after a topical exposure of reconstructed human epidermis (RHE) to equimolar solutions of either chlorhexidine digluconate (CHG, 0.144% w/v) or octenidine dihydrochloride (OCT, 0.1% w/v) for 15 min. RHE-associated antiseptic agents were more effective on Staphylococcus aureus than on Pseudomonas aeruginosa. S. aureus was not detected after 24 h of contact, which demonstrated a microbicidal efficacy of greater than 5-log<sub>10</sub> reduction. In contrast, P. aeruginosa was reduced by approximately 2 log<sub>10</sub> at the same incubation time, which parallels the growth of the initial inoculum. This result could be interpreted either as a microbiostatic effect or as an adherence of P. aeruginosa to a low positively charged surface. Small amounts of CHG and OCT can penetrate the stratum corneum. Using these antiseptic agents, the viability of keratinocytes was reduced to 65-75% of that of the untreated RHE control following 24 h incubation in the presence of test microorganisms. With consideration of antimicrobial activity and cytotoxic effect, OCT corresponds better to a biocompatible antiseptic agent than CHG.
Because of its antimicrobial properties, nonthermal plasma could serve as an alternative to chemical antisepsis in wound treatment. Therefore, this study investigated the inactivation of biofilm-embedded Pseudomonas aeruginosa SG81 by a surface barrier-discharged (SBD) plasma for 30, 60, 150 and 300 s. In order to optimize the efficacy of the plasma, different carrier gases (argon, argon admixed with 1% oxygen, and argon with increased humidity up to approx. 80%) were tested and compared against 0.1% chlorhexidine digluconate (CHG) exposure for 600 s. The antimicrobial efficacy was determined by calculating the difference between the numbers of colony-forming units (CFU) of treated and untreated biofilms. Living bacteria were distinguished from dead by fluorescent staining and confocal laser scanning microscopy. Both SBD plasmas and CHG showed significant antimicrobial effects compared to the untreated control. However, plasma treatment led to a higher antimicrobial reduction (argon plasma 4.9 log<sub>10</sub> CFU/cm<sup>2</sup>, argon with admixed oxygen 3 log<sub>10</sub> CFU/cm<sup>2</sup>, and with increased gas humidity 2.7 log<sub>10</sub> CFU/cm<sup>2</sup> after 300 s) compared to CHG. In conclusion, SBD plasma is suitable as an alternative to CHG for inactivation of Pseudomonas aeruginosa embedded in biofilm. Further development of SBD plasma sources and research on the role of carrier gases and humidity may allow their clinical application for wound management in the future.
Multiple evidence in animal models and in humans suggest a beneficial role of cold physical
plasma in wound treatment. Yet, risk assessment studies are important to further foster therapeutic
advancement and acceptance of cold plasma in clinics. Accordingly, we investigated the long-term
side effects of repetitive plasma treatment over 14 consecutive days in a rodent full-thickness ear
wound model. Subsequently, animals were housed for 350 days and sacrificed thereafter. In blood,
systemic changes of the pro-inflammatory cytokines interleukin 1β and tumor necrosis factor α
were absent. Similarly, tumor marker levels of α-fetoprotein and calcitonin remained unchanged.
Using quantitative PCR, the expression levels of several cytokines and tumor markers in liver,
lung, and skin were found to be similar in the control and treatment group as well. Likewise,
histological and immunohistochemical analysis failed to detect abnormal morphological changes
and the presence of tumor markers such as carcinoembryonic antigen, α-fetoprotein, or the neighbor
of Punc 11. Absence of neoplastic lesions was confirmed by non-invasive imaging methods such as
anatomical magnetic resonance imaging and positron emission tomography-computed tomography.
Our results suggest that the beneficial effects of cold plasma in wound healing come without apparent
side effects including tumor formation or chronic inflammation.
Introduction: Antiseptics are used for the prophylaxis of infections of acute wounds and for the treatment of critically colonized chronic wounds as well as localized infections of acute and chronic wounds. If an antiseptic with too much tissue toxicity and/or too little efficacy is used, the wound healing can be delayed.
Objective: The aim was to compare the irritation potency of frequently used wound antiseptics by using the hen's egg test on the chorioallantoic membrane (HET-CAM). Additionally, the influence of antiphlogistic active additives which might increase the tolerability was examined. To allow a more extensive comparison, antiseptics classified as obsolete such as hydrogen peroxide, creams on PVP- iodine base, silver sulfadiazine, chlorhexidine and nitrofural as well as the non-antiseptic wound treatment agents dexpanthenol and hemoglobin spray were also examined.
Method: The HET-CAM was used as a semi-in-vivo method to test the tolerability of wound antiseptics to tissues by observing the reactions that occur in the blood vessels of the highly vascularized CAM such as hemorrhage, lysis and coagulation. The irritation score (IS) was calculated and differentiated in 4 ranges according to Spielmann (1991).
Results: The vascular injuries of the CAM were considered as an indirect indicator of the tolerability. It is accepted that agents with no or low irritation potential on the CAM are to be preferred in the clinical practice if they are clinically effective.
Severe CAM reaction was observed after short-term application of octenidine based wound gel (active ingredient octenidine 0.05%) (IS: 10.3) and chlorhexidine digluconate 0.5% solution (IS: 9.5). Moderate reaction was observed for the combination of octenidine 0.05% in aqueous solution with panthenol 1.34% and allantoin 0.2% (IS: 8.7), hydrogen peroxide 1.5% in aqueous solution (IS: 6.1) and hydrogen peroxide 0.5% solution (IS: 5.5). Slight reaction was observed for hydrogen peroxide 1.5% solution in combination with sodium thiocyanate 0.698% (IS: 2.6), sodium thiocyanate 0.698% solution (IS: 2.1) and Dermacyn® (active ingredient NaOCl/HOCl each 0.004) (IS: 1.2). Polihexanide 0.04% in Ringer solution (IS: 0.9), Polihexanide 0.05% in Lipofundin, Granulox® (active agent hemoglobin 10%) (IS: 0) and dexpanthenol 5% solution (IS: 0) showed no reaction. In the long-term observation (24 hours after application), Dermacyn® showed the best results (59% of irritation remained alive after 24 hours). The addition of dexpanthenol and allantoin reduced the irritability only slightly, whereas the decrease of IS of hydrogen peroxide by addition of sodium thiocyanate was almost significant (p 0.0596).
Conclusion: It is suggested that agents with no or low irritation potential on the CAM are to be preferred in the clinical practice if they are clinically effective. It is suggested that further in vivo and in vitro studies are to be undertaken with these agents.
Solely regarding local tolerability, polihexanide and hypochlorite are the antiseptic agents of choice of the tested preparations. The wound oxygenizer hemoglobin spray is tolerated without irritation as well as the negative control 0.9% NaCl solution. Because of their other disadvantages in conjunction with their irritability, the outdated cream formulations on basis of silver sulfadiazine, PVP- iodine, chlorhexidine and nitrofural cannot be recommended for wound antisepsis.
Biocidal Agents Used for Disinfection Can Enhance Antibiotic Resistance in Gram-Negative Species
(2018)
Background: Annual transfusion rates in many European countries range between 25 and 35 red blood cell concentrates (RBCs)/1,000 population.It is unclear why transfusion rates in Germany are considerably higher (approx. 50–55 RBCs/1,000 population). Methods: We assessed the characteristics of transfusion recipients at all hospitals of the German federal state Mecklenburg-Western Pomerania during a 10-year longitudinal study. Results: Although 75% of patients received ≤4 RBCs/patient in 2015 (1 RBC: 11.3%; 2 RBCs: 42.6%; 3 RBCs: 6.3%; 4 RBCs: 15.0%), the mean transfusion index was 4.6 RBCs due to a minority of patients with a high transfusion demand. Two thirds of all RBCs were transfused to only 25% of RBC recipients. Consistently, male patients received a higher number of RBCs (2005: 54.2%; 2015: 56.8%) and had a higher mean transfusion index than female patients (mean 5.1 ± 7.2; median 2; inter-quartile range [IQR] 2–4 vs. mean 4.0 ± 5.8; median 2; IQR 2–4). The absolute transfusion demand decreased between 2005 and 2015 by 13.5% due to a composite of active reduction (clinical practice change) and population decline in the 65- to 75-year age group (lower birth rate cohort 1940–1950); however, with major differences between hospitals (range from –61.0 to +41.4%). Conclusion: Transfusion demand in a population could largely be driven by patients with high transfusion demand. Different treatment practices in this group of patients probably add to the major differences in transfusion demand per 1,000 individuals between countries. The available data cannot prove this hypothesis. Implementation of a diagnosis-related group-based monitoring system is urgently needed to allow informative monitoring on the population level and meaningful comparisons between transfusion practices.
Abstract
Antimicrobial coating of implant material with poly(hexamethylene biguanide) hydrochloride (PHMB) may be an eligible method for preventing implant‐associated infections. In the present study, an antibacterial effective amount of PHMB is adsorbed on the surface of titanium alloy after simple chemical pretreatment. Either oxidation with 5% H2O2 for 24 hr or processing for 2 hr in 5 M NaOH provides the base for the subsequent formation of a relatively stable self‐assembled PHMB layer. Compared with an untreated control group, adsorbed PHMB produces no adverse effects on SaOs‐2 cells within 48 hr cell culture, but promotes the initial attachment and spreading of the osteoblasts within 15 min. Specimens were inoculated with slime‐producing bacteria to simulate a perioperative infection. Adsorbed PHMB reacts bactericidally against Staphylococcus aureus, Staphylococcus epidermidis, and Pseudomonas aeruginosa after surface contact. Adhered SaOs‐2 cells differentiate and produce alkaline phosphatase and deposit calcium within 4 days in a mineralization medium on PHMB‐coated Ti6Al4V surfaces, which have been precontaminated with S. epidermidis. The presented procedures provide a simple method for generating biocompatibly and antimicrobially effective implant surfaces that may be clinically important.