Keywords
- supercritical fluid chromatography (2) (remove)
Institute
- Institut für Pharmazie (2) (remove)
Eicosanoids are lipid mediators generated from arachidonic acid with pro- and anti-inflammatory properties. Despite these lipid mediators being known for decades, quantitative determination in biological samples is still challenging due to low abundance, instability, the existence of regio- and stereoisomers, and a wide polarity range that hampers chromatographic separation. In this study, we developed a supercritical fluid chromatography mass spectrometry (SFC-MS) platform for the quantification of relevant eicosanoids. Application of a chiral amylose-based column and modifier combination of 2-propanol/acetonitrile offered separation and sufficient resolution of 11 eicosanoids (5-, 12-, 15-HETE, PGB1, LTB4, t-LTB4, 20-OH-LTB4, PGE2, PGD2, PGF2α, TxB2) with baseline separation of isobaric analytes within 12 min. The method was validated in terms of range (78–2500 ng/mL), linearity, accuracy, precision, and recovery according to EMA guidelines. Finally, we confirmed the method’s applicability by quantifying eicosanoid levels in human primary blood cells. In conclusion, we present a validated SFC-MS method for the determination of relevant eicosanoids in biological samples with a wide range of polarity while maintaining baseline separation of isobars, which allows coupling to a single quadrupole mass detector.
Abstract
Saliva is an attractive sampling matrix for measuring various endogenous and exogeneous substances but requires sample treatment prior to chromatographic analysis. Exploiting supercritical CO2 for both extraction and chromatography simplifies sample preparation, reduces organic solvent consumption, and minimizes exposure to potentially infectious samples, but has not yet been applied to oral fluid. Here, we demonstrate the feasibility and benefits of online supercritical fluid extraction coupled to supercritical fluid chromatography and single‐quadrupole mass spectrometry for monitoring the model salivary tracer caffeine. A comparison of 13C‐ and 32S‐labeled internal standards with external standard calibration confirmed the superiority of stable isotope‐labeled caffeine over nonanalogous internal standards. As proof of concept, the validated method was applied to saliva from a magnetic resonance imaging study of gastric emptying. After administration of 35 mg caffeine via ice capsule, salivary levels correlated with magnetic resonance imaging data, corroborating caffeine's usefulness as tracer of gastric emptying (R2 = 0.945). In contrast to off‐line methods, online quantification required only minute amounts of organic solvents and a single manual operation prior to online bioanalysis of saliva, thus demonstrating the usefulness of CO2‐based extraction and separation techniques for potentially infective biomatrices.