Refine
Document Type
- Article (3)
Language
- English (3)
Has Fulltext
- yes (3)
Is part of the Bibliography
- no (3)
Keywords
- - (3)
- Breast cancer (2)
- Nipple discharge (2)
- Abdominal fat (1)
- Ductoscopy (1)
- Endoscopic breast ductoscopy (1)
- Intraductal lesion (1)
- Leptin (1)
- Mammography (1)
- Sonography (1)
Institute
Publisher
- S. Karger AG (3) (remove)
Background: This study aims to assess the role of ductoscopy for detecting intraductal anomalies in patients with nipple discharge in comparison to conventional tests and to find an effective combination of both approaches. Materials and Methods: Prior to duct excision, ductoscopy was performed in 97 women. Histologic and all other diagnostic results were compared. Sensitivity, specificity, and efficiency were calculated for all methods. These parameters were also calculated for all possible test combinations in 12 patients who had completed all tests. Results: Breast sonography reached the highest sensitivity (64.1%) and efficiency (64%); mammography had the highest specificity (100%). The sensitivity of ductoscopy was 53.2%, its specificity 60%, and its efficiency 55.1%. Among combinations of all methods, the combination ductoscopy + galactography was the most sensitive (80%). Mammography, magnetic resonance imaging, and ductoscopy were each 100% specific. Ductoscopy was the most efficient (75%) single method. Conclusion: Ductoscopy is a valuable test for diagnosing intraductal lesions in patients with nipple discharge. It is more efficient than conventional tests in patients undergoing all tests.
SummaryBackground: According to the literature, ductoscopy is gaining increasing importance in the diagnosis of intraductal anomalies in cases of pathologic nipple discharge. In a multicenter study, the impact of this method was assessed in comparison with that of standard diagnostics. Patients and Methods: Between 09/2006 and 05/2009, a total of 214 patients from 7 German breast centers were included. All patients underwent elective ductoscopy and subsequent ductal excision because of pathologic nipple discharge. Ductoscopy was compared with the following standard diagnostics: breast sonography, mammography, magnetic resonance imaging (MRI), galactography, cytologic nipple swab, and ductal lavage cytology. The histological and imaging results were compared and contrasted to the results obtained from the nipple swab and cytologic assessment. Results: Sonography had the highest (82.9%) sensitivity, followed by MRI (82.5%), galactography (81.3%), ductoscopy (71.2%), lavage cytology (57.8%), mammography (57.1%), and nipple swab (22.8%). Nipple swabs had the highest (85.5%) specificity, followed by lavage cytology (85.2%), ductoscopy (49.4%), galactography (44.4%), mammography (33.3%), sonography (17.9%), and MRI (11.8%). Conclusion: Currently, ductoscopy provides a direct intraoperative visualization of intraductal lesions. Sensitivity and specificity are similar to those of standard diagnostics. The technique supports selective duct excision, in contrast to the unselective technique according to Urban. Therefore, ductoscopy extends the interventional/diagnostic armamentarium.
Background: Abdominal obesity is a major driver for adverse medical conditions. While an interaction between adipose tissue and thyroid function is thought to exist, to our knowledge, no study has examined the effect of thyroid-stimulating hormone (TSH) on visceral adipose tissue (VAT) in a population-based context. Objective: We determined an association between serum TSH levels and VAT. Methods: A sample of 1,021 female and 956 male adults aged 20-79 years was drawn from registry offices in the cross-sectional, population-based Study of Health in Pomerania Trend (SHIP Trend) in Northeast Germany from 2008 to 2012. Our main exposure was serum TSH levels. Our main outcome was VAT measured using magnetic resonance imaging. The possibly mediating role of leptin on the TSH-VAT association was also assessed. Results: A total of 1,719 participants (87.9%) had serum TSH levels within the reference range. The mean volume of VAT was 5.33 liters for men and 2.83 liters for women. No association between TSH and VAT (β = 0.06, 95% CI: -0.02, 0.14) was observed, and there were no differences detected between sexes. VAT was strongly associated with leptin with a greater effect in women than in men. Leptin was strongly associated with TSH. Conclusions: No association between TSH and VAT was observed. Other biomarkers such as leptin may play a role in the relationship between thyroid function and metabolic risk.