Background
Vulnerable groups, e.g. persons with mental illness, neurological deficits or dementia, are often excluded as participants from research projects because obtaining informed consent can be difficult and tedious. This may have the consequence that vulnerable groups benefit less from medical progress. Vulnerable persons are often supported by a legal guardian in one or more demands of their daily life. We examined the attitudes of legal guardians and legally supervised persons towards medical research and the conditions and motivations to participate in studies.
Methods
We conducted a cross-sectional study with standardized surveys of legal guardians and legally supervised persons. Two separate questionnaires were developed for the legal guardians and the supervised persons to asses previous experiences with research projects and the reasons for participation or non-participation. The legal guardians were recruited through various guardianship organizations. The supervised persons were recruited through their legal guardian and from a previous study among psychiatric patients. The data were analysed descriptively.
Results
Alltogether, 82 legal guardians and 20 legally supervised persons could be recruited. Thereof 13 legal guardians (15.6%) and 13 legally supervised persons (65.0%) had previous experience with research projects. The majority of the guardians with experience in research projects had consented the participation of their supervised persons (n = 12 guardians, 60.0%; in total n = 16 approvals). The possible burden on the participating person was given as the most frequent reason not to participate both by the guardians (n = 44, 54.4%) and by the supervised persons (n = 3, 30.0%). The most frequent motivation to provide consent to participate in a research study was the desire to help other patients by gaining new scientific knowledge (guardians: n = 125, 78.1%; supervised persons: n = 10, 66.6%).
Conclusions
Overall, an open attitude towards medical research can be observed both among legal guardians and supervised persons. Perceived risks and no sense recognized in the study are reasons for not participating in medical research projects.
Background
Numerous wearables are used in a research context to record cardiac activity although their validity and usability has not been fully investigated. The objectives of this study is the cross-model comparison of data quality at different realistic use cases (cognitive and physical tasks). The recording quality is expressed by the ability to accurately detect the QRS complex, the amount of noise in the data, and the quality of RR intervals.
Methods
Five ECG devices (eMotion Faros 360°, Hexoskin Hx1, NeXus-10 MKII, Polar RS800 Multi and SOMNOtouch NIBP) were attached and simultaneously tested in 13 participants. Used test conditions included: measurements during rest, treadmill walking/running, and a cognitive 2-back task. Signal quality was assessed by a new local morphological quality parameter morphSQ which is defined as a weighted peak noise-to-signal ratio on percentage scale. The QRS detection performance was evaluated with eplimited on synchronized data by comparison to ground truth annotations. A modification of the Smith-Waterman algorithm has been used to assess the RR interval quality and to classify incorrect beat annotations. Evaluation metrics includes the positive predictive value, false negative rates, and F1 scores for beat detection performance.
Results
All used devices achieved sufficient signal quality in non-movement conditions. Over all experimental phases, insufficient quality expressed by morphSQ values below 10% was only found in 1.22% of the recorded beats using eMotion Faros 360°whereas the rate was 8.67% with Hexoskin Hx1. Nevertheless, QRS detection performed well across all used devices with positive predictive values between 0.985 and 1.000. False negative rates are ranging between 0.003 and 0.017. eMotion Faros 360°achieved the most stable results among the tested devices with only 5 false positive and 19 misplaced beats across all recordings identified by the Smith-Waterman approach.
Conclusion
Data quality was assessed by two new approaches: analyzing the noise-to-signal ratio using morphSQ, and RR interval quality using Smith-Waterman. Both methods deliver comparable results. However the Smith-Waterman approach allows the direct comparison of RR intervals without the need for signal synchronization whereas morphSQ can be computed locally.
Mean platelet volume is more important than age for defining reference intervals of platelet counts
(2019)
Background
Since the onset of the COVID-19 pandemic, children have been mentally and physically burdened, particularly due to school closures, with an associated loss of learning. Therefore, efficient testing strategies with high sensitivity are necessary to keep schools open. Apart from individual rapid antigen testing, various methods have been investigated, such as PCR-based pool-testing of nasopharyngeal swabs, gargle, or saliva samples. To date, previous validation studies have found the PCR-based saliva swab pool testing method to be an effective screening method, however, the acceptability and feasibility of a widespread implementation in the school-setting among stakeholders has not been comprehensively evaluated.
Methods
In this pilot study, SARS-CoV-2 saliva swab pool testing of up to 15 swabs per pool was conducted in ten primary and special schools in Mecklenburg-Western Pomerania, Germany, over a period of one month. Thereafter, parents, teachers and school principals of the participating schools as well as the participating laboratories were surveyed about the feasibility and acceptability of this method, its large-scale implementation and challenges. Data were analyzed quantitatively and qualitatively.
Results
During the study period, 1,630 saliva swab pools were analyzed, of which 22 tested SARS-CoV-2 positive (1.3%). A total of N = 315 participants took part in the survey. Across all groups, the saliva swab pool testing method was perceived as more child-friendly (>87%), convenient (>82%), and easier (>81%) compared to rapid antigen testing by an anterior nasal swab. Over 80% of all participants favored widespread, regular use of the saliva swab method.
Conclusion
In school settings in particular, a high acceptability of the test method is crucial for a successful SARS-CoV-2 surveillance strategy. All respondents clearly preferred the saliva swab method, which can be used safely without complications in children six years of age and older. Hurdles and suggestions for improvement of an area-wide implementation were outlined.
Background
In the German health care system, parents with an acutely ill child can visit an emergency room (ER) 24 hours a day, seven days a week. At the ER, the patient receives a medical consultation. Many parents use these facilities as they do not know how urgently their child requires medical attention. In recent years, paediatric departments in smaller hospitals have been closed, particularly in rural regions. As a result of this, the distances that patients must travel to paediatric care facilities in these regions are increasing, causing more children to visit an ER for adults. However, paediatric expertise is often required in order to assess how quickly the patient requires treatment and select an adequate treatment. This decision is made by a doctor in German ERs. We have examined whether remote paediatricians can perform a standardised urgency assessment (triage) using a video conferencing system.
Methods
Only acutely ill patients who were brought to a paediatric emergency room (paedER) by their parents or carers, without prior medical consultation, have been included in this study. First, an on-site paediatrician assessed the urgency of each case using a standardised triage. In order to do this, the Paediatric Canadian Triage and Acuity Scale (PaedCTAS) was translated into German and adapted for use in a standardised IT-based data collection tool. After the initial on-site triage, a telemedicine paediatrician, based in a different hospital, repeated the triage using a video conferencing system. Both paediatricians used the same triage procedure. The primary outcome was the degree of concordance and interobserver agreement, measured using Cohen’s kappa, between the two paediatricians. We have also included patient and assessor demographics.
Results
A total of 266 patients were included in the study. Of these, 227 cases were eligible for the concordance analysis. In n = 154 cases (68%), there was concordance between the on-site paediatrician’s and telemedicine paediatrician’s urgency assessments. In n = 50 cases (22%), the telemedicine paediatrician rated the urgency of the patient’s condition higher (overtriage); in 23 cases (10%), the assessment indicated a lower urgency (undertriage). Nineteen medical doctors were included in the study, mostly trained paediatric specialists. Some of them acted as an on-site doctor and telemedicine doctor. Cohen’s weighted kappa was 0.64 (95% CI: 0.49–0.79), indicating a substantial agreement between the specialists.
Conclusions
Telemedical triage can assist in providing acute paediatric care in regions with a low density of paediatric care facilities. The next steps are further developing the triage tool and implementing telemedicine urgency assessment in a larger network of hospitals in order to improve the integration of telemedicine into hospitals’ organisational processes. The processes should include intensive training for the doctors involved in telemedical triage.